Insert bare wires fully into the terminal block and
tighten securely. Keep wiring tails to a minimum and
check that wires do not interfere with the operating
mechanism. Use the earthing / grounding points
provided.
End of line resistors
Some products may be supplied to order fitted with
end of line resistors. Resistors in use may generate
a heat source. The type, quantity, configuration,
fitment method and allowable electrical loads are
limited by the scope of the certification.
NEVER FIT END OF LINE RESISTORS OR
MODIFY WITHOUT REFERENCE TO
DELTA MOBREY
Replacing cover / lid on
Flameproof enclosures
BEFORE CLOSING THE LID:
ENSURE WIRE IS CLEAR OF ALL
MOVING PARTS.
ENSURE THAT WIRES DO NOT
TOUCH THE LID AS IT IS CLOSED.
Thread, seal and contact surfaces may be lightly
lubricated using a non-setting non-corrosive grease
compatible with the lid seal.
DO NOT USE COPPER BEARING
GREASE ON ALUMINIUM.
Before connecting to electrical power,
screw on cover/lid hand tight making
sure that mating surfaces of the lid and enclosure
are in contact. Use the locking screw provided to
prevent casual and unauthorised removal of the
cover/lid.
IT IS A SAFETY REQUIREMENT THAT AT
LEAST 5 FULL THREADS ARE ENGAGED
BETWEEN THE COVER / LID AND THE
ENCLOSURE WHEN THE UNIT IS IN
OPERATION. NEVER OPERATE THE
UNIT UNLESS THIS CONDITION IS MET.
ATEX
ATEX
ATEX
ATEX
Installation of electrical adaptors and
cable glands to the electrical entry
Either one or two electrical entries can be provid-
ed. The standard entry is a single ISO M20 x 1.5
thread. Other non-ISO and tapered threads will
have their size and type stamped on the enclosure
next to the entry.
TAKE CARE TO SELECT AND INSTALL
ADAPTORS THAT DO NOT REDUCE
THE ENCLOSURE’S DEGREE OF PRO-
TECTION WHEN IN USE IN ZONE 1
HAZARDOUS AREAS.
UNUSED ENTRIES MUST BE FITTED
WITH SUITABLY CERTIFIED FLAME-
PROOF STOPPING PLUGS.
IT IS A SAFETY REQUIREMENT THAT
AT LEAST 5 FULL THREADS ARE EN-
GAGED BETWEEN THE ADAPTER,
CABLE GLAND OR STOPPING PLUG,
AND THE ELECTRICAL ENTRY WHEN
THE UNIT IS IN OPERATION. NEVER
OPERATE THE UNIT UNLESS THIS
CONDITION IS MET.
Alternative electrical entry threads
One or two electrical entries can be supplied with
the following optional thread types:
ISO to BS 3643 (1981) medium fit 6H up to
M25 x 1.5
DIN 40430 (1971) up to Pg21.
USAS B2.1 (1968) gauging to clauses 36 & 37
up to 3/4" NPT.
BS conduit to BS31 (1940) table 'A' up to 1"
BSP to BS21(1985) standard threads only as
clause 5.4 gauging to clause 5.2 system 'A' up
to Rp3/4 (medium fit or better).
Wiring
DISCONNECT ALL SUPPLY CIRCUITS
BEFORE WIRING
WIRE IN ACCORDANCE WITH LOCAL
AND NATIONAL CODES. USE CABLES
NO LARGER THAN 2.5 MM 2 (14 AWG)
DO NOT EXCEED ELECTRICAL RAT-
INGS STATED IN LITERATURE AND ON
NAMEPLATES.
The three switch terminals are clearly marked
“NORMALLY CLOSED”, “NORMALLY OPEN” and
“COMMON”. The following diagram can be used as
a guide for wiring.
ATEX
ATEX
Fig 2