Define Instruments TEX-TOTAL Manual de usuario

TEX-TOTAL-MAN-15V03 (1002)Copyright © 2015 Dene Instruments
1
The TEX-TOTAL rate meter and totalizer
is ideal for ow rate monitoring of trans-
mitters and sensors with mA output.
It features dual totalizers with low ow
cut-o and roll over, and input signal av-
eraging to stabilise measurement.
The TEX-TOTAL features a 6-digit alpha-
numeric LED display, with scrolling text
prompts that guide you step-by-step
through the setup process. The unit is
easy to scale to suit your desired time
and measurement units.
TEX-TOTAL
Flow Rate Totalizer
Order Codes
TEX-TOTAL Flow Rate Totalizer
–HV
–LV
85–265V AC / 95–370V DC
15–48V AC / 10–72V DC
Options
–R2
–R4
2 x relay outputs
4 x relay outputs
–A1 x mA/V analog output
–S2R 1 x RS232 (RJ11 terminal)
–S4S 1 x RS485 (screw terminal)
Contents
1 - Specications ............................. 2
2 - Front Panel & Display ................ 3
3 - Wiring ......................................... 5
4 - Dimensions & Installation .......... 8
5 - Input Setup & Calibration ....... 10
6 - Totalizer Reset & Setpoint
Setup .......................................... 16
7 - Setpoint Direct Access............... 20
8 - Reset PIN Numbers / View
Firmware Version...................... 20
A - Appendix A - Serial Modes........ 21

TEX-TOTAL-MAN-15V03 (1002) Copyright © 2015 Dene Instruments
2
1 SPECIFICATIONS
Input
Input signal Current (0/4–20mA)
Power supply
HV= 85–265V AC / 95–370V DC, or
LV= 15–48V AC / 10–72V DC
Excitation 24V DC (50mA max)
Sampling rate 10Hz
Resolution 16 bit
Accuracy 0.05% of reading
Ambient dri 50ppm/°C typical
Flow rate /sec, /min or /hour
Flow resolution 1, 0.1, 0.01 or 0.001
Totalizers Dual totalizers
Totalizer resolution x0.1, x1, x10, x100
or x1000
Noise rejection 50/60Hz
Relay Output
Number of relay outputs None, 2, or 4
Relay output type 5A form A (3A 240V
AC max or 3A 30V DC max)
Analog Output
Analog output (Optional) Isolated 16
bit 4–20mA/0–10V
Comm Port
Serial port (Optional) Isolated RS232 or
RS485 (select when placing your order)
Programming
Front panel buttons Up, Down, P
(Prog/Enter), plus 2x Function Buttons
for menu access
Security Input and setpoint setups
are independently accessible and PIN
protected
Display
Display type LED display, 5 buttons
LED indicators 6 setpoint indicator LED's
Digits 1 row of 6 digits, 13mm (0.5"), 14
segment alphanumeric LED
Construction
Casing Panel mount case
Ingress protection rating IP65 dust/
splash proof (face only)
Dimensions (H x W x D)
48 x 96 x 120mm (1.89 x 3.78 x 4.72")
Panel cutout 45 x 92mm (1.77 x 3.62")
OPTIONAL
OPTIONAL
OPTIONAL

TEX-TOTAL-MAN-15V03 (1002)Copyright © 2015 Dene Instruments
3
2 FRONT PANEL & DISPLAY
2.1 - Front panel
SPX The SP LED's are used to
indicate active setpoints.
This button is used to ac-
cess the Input Setup & Calibra-
tion menu (Section 5).
This button is used to save
96mm (3.78")
48mm
(1.89")
your settings and advance to the next step in the setup process.
This button is typically used to scroll through options or increase values in the
setup menu. Pressing this button from the main display will allow you to view/reset
the Peak value, and view the Total 1 value (see 2.3).
This button is typically used to scroll through options or decrease values in the
setup menu. Pressing this button from the main display will allow you to view/reset
the Valley value, and view the Total 2 value (see 2.3).
This button is used to access the Totalizer Reset & Setpoint Setup menu (Sec-
tion 6) and the Setpoint Direct Access menu (Section 7).
2.2 - Display brightness
To adjust the display brightness, press the and buttons together from the
main display. BRI appears and toggles with the current setting. Use the and
buttons to adjust the LED backlight, and then press to nish.

TEX-TOTAL-MAN-15V03 (1002) Copyright © 2015 Dene Instruments
4
2.3 - Up and down button shortcuts
Pressing the and buttons from the main operational display allows instant
access to a number of values held in the controller's memory. These variables will ap-
pear in the order shown in the table below, and will cycle continuously at each press
of the or button. Press at any time to return to normal operating mode.
PEAK and VALLEY may be reset to zero by pressing the and buttons at the
same time while the variable is being displayed.
Up and down button shortcuts
PEAK Maximum measured ow rate since the instrument was turned on/reset
TOTAL1 Current value of Total 1.
Total 1 will not appear in this list if it is set as your display source (5.5).
This value can be reset in 6.2B, or by the input pins (3.6).
VALLEY Minimum measured ow rate since the instrument was turned on/reset
TOTAL2 Current value of Total 2.
Total 2 will not appear in this list if it is set as your display source (5.5).
This value can be reset in 6.2C, or by the input pins (3.6).

TEX-TOTAL-MAN-15V03 (1002)Copyright © 2015 Dene Instruments
5
3 WIRING
BEFORE YOU BEGIN WIRING, ensure that the unit is switched o and the power
supply is disconnected.
3.1 - Pinouts
DEF
A B C
Key
3.1A Relay Output (See 3.3)
3.1B Serial Port (See 3.5)
3.1C Analog Output (See 3.4)
3.1D Analog Input (See 3.2)
3.1E Function Pins (See 3.6)
3.1F Power Supply HV/LV
(See 3.7)
3.2 - Wire the analog input module See 3.1D
Wire your analog input module as required, referring to the diagrams below.
I
SENSOR
+ POS
+ 24V
EXC
2-Wire Current Input
Loop Powered Sensor
3-Wire Current Input
Controller Supplied EXC
I
+ Signal
-
Signal /
-
Supply
+ POS
-
NEG
+ 24V
EXC
+ Supply
EXTERNAL
+ Supply
-
Supply
I/V
+ Signal
-
Signal
+ POS
-
NEG
2-Wire Current Input
External Excitation Used

TEX-TOTAL-MAN-15V03 (1002) Copyright © 2015 Dene Instruments
6
3.3 - Wire the relay outputs (if installed) See 3.1A
If your controller has relay outputs tted, wire them as shown below. Relays can be
programmed to operate within the total span range of the controller.
SP2 SP1
-R2
SP2 SP1
SP4 SP3
-R4
3.4 - Wire the analog output (if installed)
See 3.1C
If your controller has analog output tted, wire it as shown for either
voltage (0–10V) or current (4–20mA).
–V
+V
–mA
+mA
-A
3.5 - Wire the serial port (if installed)
See 3.1B
If your controller has serial port tted, wire it as
shown in the applicable diagram.
›S2R: RS232, RJ11 terminal
›S4S: RS485, screw terminal
N/C
SGND
+5V DC (option)
RXD
TXD
N/C
-S2R
D
-
D +
SGND
-S4S

TEX-TOTAL-MAN-15V03 (1002)Copyright © 2015 Dene Instruments
7
3.6 - Wire the function pins
See 3.1E
Connect external switches as shown to enable a
function to be executed when its switch is activated.
›Total 1 Resets Total 1 to zero (also see 6.2B)
›Total 2 Resets Total 2 to zero (also see 6.2C)
›Test Resets the meter
›Pk/Val Clears the Peak & Valley readings
(also see 2.3)
Total 1 TestTotal 2 COM Pk/Val
3.7 - Wire the power supply See 3.1F
DO NOT attempt to wire your controller while the power is on. NEVER connect your
low voltage controller to mains power.
Wire your controller for low or high voltage power supply, as show in the diagrams
below. Check the label on the unit against the colour of the connector:
›Orange =
High voltage (85–265V AC,
95–370V DC)
›Black =
Low voltage (15–48V AC,
10–72V DC)
High
voltage
(HV)
HV power
supply
−DC
Neutral
AC
+DC
Live
AC
Low
voltage
(LV)
LV power
supply
−DC
Neutral
AC
+DC
Live
AC
Once you have completed the wiring process it is safe to switch on your power
supply. Ensure that your display is functioning before you proceed.

TEX-TOTAL-MAN-15V03 (1002) Copyright © 2015 Dene Instruments
8
4 DIMENSIONS & INSTALLATION
4.1 - Case dimensions
Cabling
Allowance
96mm
(3.78")
92mm
(3.62")
120mm (4.72") 39mm (1.54")
155mm (6.10") minimum depth required behind panel
4mm (0.16")
Cabling
Allowance
48mm
(1.89")
45mm
(1.77")
120mm (4.72") 39mm (1.54")
155mm (6.10") minimum de
p
th re
q
uired behind
p
anel
4mm (0.16")

TEX-TOTAL-MAN-15V03 (1002)Copyright © 2015 Dene Instruments
9
4.2 - Installation instructions
A Prepare the Panel Cutout to
92 x 45mm ±.5 (3.62 x 1.77" ±.02),
as shown below. Allow at least
155mm (6.10") depth behind the
panel to accommodate the meter
body and protruding cabling.
B Remove the Mounting Clips from
the meter back.
C Slide the Panel Gasket over the
rear of the unit to the back of the
Meter Faceplate.
D From the front of the panel, insert
the meter into the Panel Cutout.
Holding the unit in place, engage
the Mounting Clips so that the tabs
snap into place over the notches on
the case.
E To achieve a proper seal, tighten
the Screws evenly until the unit sits
rmly against the panel. Do not
over-tighten the screws.
Panel Meter Faceplate
Panel
Gasket
Mounting
Clips
Screws 92mm ±.5
(3.62″ ±.02)
45mm ±.5
(1.77″ ±.02)
Panel Cutout

TEX-TOTAL-MAN-15V03 (1002) Copyright © 2015 Dene Instruments
10
5 INPUT SETUP & CALIBRATION
5.1 - Enter F1 PIN number
A Enter the calibration mode by pressing the button.
_ _ ENTER F1 PIN NUMBER scrolls across the display and toggles with 0. Use the
and buttons to enter your security code (factory default 1). Then press
. If the correct PIN is entered, setup is started at 5.2.
If an incorrect PIN number is entered, _ _ INCORRECT PIN scrolls across the
display and it returns to normal operating mode.
You will have the opportunity to change your PIN number at the end of this section
(5.10). If you have forgotten your PIN number, see Section 8.
5.2 - Flow rate input setup
A _ _ FLOW RATE INPUT SETUP scrolls across the display and toggles with SKIP.
Press to skip to 5.3, or the button and then to ENTER input setup.
B _ _ MAINS FREQUENCY scrolls across the display and toggles with the current
selection. Use the and buttons to select 50HZ or 60HZ, and press .
C _ _ TIME UNITS FOR FLOW RATE scrolls across the display and toggles with the
current time units. Use the and buttons to select: /SEC, /MIN, or /HR,
and then press .
D _ _ RESOLUTION FOR FLOW RATE scrolls across the display and toggles with
the current ow resolution. Use the and buttons to select: 1, 0.1, 0.01, or
0.001, and then press .
Tabla de contenidos
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario