PROBLEM
Unit is on, but
no sound is heard
Unit is on, but plays the
same sound over and
over, regardless
of the settings
Unit is not operating
properly in the
DAY or NIGHT mode
Unit does not function
properly when connected
to a 12-Volt battery
• Check volume settings.
• Check time of operation settings.
• Check that at least one sound is
selected to play.
• Reset the unit by turning it
off for 30 seconds and then
back on.
• Double check Mode
switch settings.
• Make sure photocell
is not obstructed.
• Make sure the photocell
is not affected by bright
lights in either the front or
the back of the unit.
• Check battery condition.
• Turn power switch on
unit to the OFF position.
Reconnect the battery,
wait 30 seconds, then
switch the unit back on.
SOLUTION
Deer Shield Super Pro Instructions P/N 655-0069-00 (Rev. 5-24-2011)
©2011 Deer Shield® Super Pro from the makers of Bird Gard. Deer Shield®
is a registered trademark. EPA Establishment Number 075130-OR-001
DEER SHIELD LIMITED WARRANTY
IF YOU ARE NOT COMPLETELY SATISFIED, CONTACT THE PLACE
OF PURCHASE OR OUR CUSTOMER SERVICE DEPARTMENT
WITHIN ONE (1) YEAR OF YOUR DATE OF PURCHASE FOR PROMPT
AND COURTEOUS REPLACEMENT, REPAIR OR REFUND.
DEER SHIELD'S LIABILITY HEREUNDER SHALL BE LIMITED TO
REFUNDING THE PURCHASE PRICE PAID BY CUSTOMER OR
REPLACING THE PRODUCT, IN DEER SHIELD'S SOLE DISCRETION,
AND UNDER NO CIRCUMSTANCES SHALL DEER SHIELD BE
LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES,
OF ANY NATURE WHATSOEVER, ARISING FROM THE CUSTOMER'S
USE OR OPERATION OF THE PRODUCT; PROVIDED, HOWEVER,
THAT THIS LIMITATION MAY BE LIMITED BY STATE LAW.
EXCEPT FOR THE EXPRESS ONE-YEAR LIMITED WARRANTY
SPECIFICALLY DESCRIBED HEREIN, DEER SHIELD DISCLAIMS
ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, RELATING TO
THE PRODUCT, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF
FITNESS; AND THE EXPRESS WARRANTIES ARE IN LIEU OF ALL
OBLIGATIONS OR LIABILITIES ON THE PART OF DEER SHIELD
ARISING OUT OF OR IN CONNECTION WITH THE SALE, USE, OR
OPERATION OF THE PRODUCT.
The Random Mode is recommended to keep deer
from adapting to a preset pattern of sounds. To
operate the unit in Random mode, set Switch 5 in
Mode Settings as follows:
Switch 5 Mode
ON Random mode ON
OFF Random mode OFF
NOTE: The unit will always play for approximately 48 seconds
independent of the number of sounds that are selected.
SPEAKERS USED SWITCH
The Speakers Used switch is located just below the
OFF - ON switch. The unit will always broadcast
sounds out of one speaker at a time. You may
choose to operate only one speaker, and this may
be accomplished by moving the slide switch all the
way to the left directly above "#1". To operate two
speakers, simply slide the switch to the middle
position directly above "#1-#2". Sounds will then
broadcast out of Speaker #1, then Speaker #2,
alternating between the two speakers. To operate
four speakers, simply slide the switch all the way
to the right directly above "#1-#4". Sounds will then
broadcast out of Speaker #1, or Speaker #2, or
Speaker #3, or Speaker #4, randomly broadcasting
sounds from all four speakers, during each cycle.
PROGRAMMING EXAMPLE
Recording Switches: Results:
1, 3, 5 and 6 to “ON” position Plays Sounds 1, 3, 5 & 6
Mode Switches:
1 = “OFF” position Time Off Interval is set to
2 = “ON” position Medium, every 1 to 4 minutes
3 = “ON” position Operates during daylight
4 = “OFF” position hours only
5 = “ON” position
Sounds in random, non-sequential order
VOLUME CONTROL
The unit has a volume control dial on the front panel
of the unit. Turning the dial toward LOW will result
in reduced sound output and rotating the dial toward
HIGH will result in an increase in sound output.
CAUTION: Take care when turning the dial since the unit may be in
an inactive state when the dial is rotated. It could then reactivate at
a very high level of sound which could be painful to your ears.
POWER SWITCH
The ON - OFF power switch enables the unit to
operate. Slide the switch to the ON position to
start the unit. If you turn the unit OFF, be sure to
P.O. Box 1690 • 270 East Sun Ranch Drive
Sisters, Oregon 97759 U.S.A.
Toll-Free: (888) 332-2328 • Fax: (541) 549-5286
Website: www.DeerShieldTech.com
Switch 1 Switch 2 Time Off Period
ON OFF Short
OFF ON Medium
ON ON Long
OFF OFF Extra Long
Mode Minimum Maximum
Short 17 sec 50 sec
Medium 1 min 4:15 min
Long 5:00 min 10:00 min
XLong 10 min 30 min
TIME OF OPERATION SWITCHES
The TIME OF OPERATION
switches (two) are located just
under the TIME OFF INTERVAL
switches in the switch array. ‘Night
Mode’ operates the unit at night
and ‘Day Mode’ operates the unit during the day.
However, the photocell that senses the sunlight is
susceptible to bright lights. Take care not to have
bright lights shining towards the unit since this can
prevent the unit from operating properly. In the
‘24-Hour Mode’, the unit will operate continuously,
regardless of the time of day. To set the time period
for the unit to operate set Switches 3 and 4 in the
Mode Settings switches to the following:
Switch 3 Switch 4 Mode
ON OFF Day Only
OFF ON Night Only
OFF OFF 24-Hour Operation
RANDOM OPERATION SWITCH
The Random switch is located
as shown in the switch array.
When the Random Mode is
turned ON, the unit will randomly
play the selected recordings in
non-sequential order; the Time Off Interval will be a
randomly selected period of time within the selected
range (Short, Medium, Long, Extra Long); and the
speakers will play one at a time in a random pattern
(if the Speakers Used switch is set to operate all
four speakers). When the unit is not operating in the
Random Mode, it will play the selected recordings in
their number order; the Time Off Interval will be the
shortest time period within the selected range; and
the speakers will play one at a time in a sequence
from Speaker 1 to Speaker 4 (See Speaker Used
Switch instructions following this section).
leave it off for about 30 seconds before turning it
back on to allow the electronics to properly reset.
TROUBLESHOOTING