Datasheen D316S Manual de usuario

1

2
FCC Certifications
This Equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio
communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at
his own expense.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received; including interference that
may cause undesired operation.
CE Mark Warning
This equipment complies with the requirements relating to electromagnetic
compatibility, EN 55022 class A for ITE, the essential protection requirement of
Council Directive 89/336/EEC on the approximation of the laws of the Member
States relating to electromagnetic compatibility.
Company has an on-going policy of upgrading its products and it may be possible
that information in this document is not up-to-date. Please check with your local
distributors for the latest information. No part of this document can be copied or
reproduced in any form without written consent from the company.
Trademarks:
All trade names and trademarks are the properties of their respective companies.
Copyright © 2009, All Rights Reserved.

3
Table of Contents
UNPACKING INFORMATION....................... 5
INTRODUCTION ............................................... 5
GENERAL DESCRIPTION ...................................................5
KEY FEATURES..............................................................5
THE FRONT PANEL .........................................................6
LEDs Definition.......................................................6
THE REAR PANEL...........................................................7
INSTALLATION................................................. 8
DESKTOP INSTALLATION ..................................................8
RACK-MOUNT INSTALLATION .............................................8
INSTALLING NETWORK CABLES...........................................9
FUNCTIONAL DESCRIPTION..................... 10
FLOW CONTROL AND BACK PRESSURE ................................10
MIRROR ...................................................................10
VLAN .....................................................................10
TRUNK (AGGREGATION) ................................................10
QUALITY OF SERVICE (QOS)...........................................10
MANAGEMENT GUIDE.................................. 11
ACCESS THE SWITCH....................................................11
HOMEPAGE................................................................12
ADMINISTRATOR .........................................................13
Authentication Configuration ..................................13
System IP configuration.........................................13
System................................................................14

4
Load Default Setting .............................................14
Firmware Upgrade ................................................14
PORT MANAGEMENT .....................................................15
Port Configuration.................................................15
Port Mirroring.......................................................16
Bandwidth Control ................................................16
Broadcast Storm Control........................................17
VLAN SETTING ..........................................................18
Group VLAN Setting ..............................................18
Multi to 1 Setting..................................................18
TRUNK SETTING..........................................................19
QOSSETTING............................................................20
Priority Mode .........................................................20
Class of Service Configuration....................................21
MAC ADDRESS CONFIGURATION ......................................21
CONFIGURATION BACKUP/RECOVERY..................................22
PRODUCT SPECIFICATIONS ..................... 23

5
Unpacking Information
Thank you for purchasing the D316S 16-Ports/D324S 24-Ports Fast
Ethernet Web Smart Switch. Before you start, please verify that your
package contains the following items:
1. One 16/24-Ports Fast Ethernet Web Smart Switch
2. One power cord
3. Rack-mount brackets and screws (optional)
4. Manual CD
D316S/ D324S Introduction
General Description
Easily managing your LAN, the 16/24-Ports Fast Ethernet Web Smart Switch
provides you 16/24*10/100Mbps ports that allow more efficient
management. With the user-friendly Web-based management interface,
you can easily get the overall information of your LAN.
This device provides sufficient management functions. VLAN reduces the
collisions from widely broadcasting. Port Aggregation enlarges the
bandwidth of backbone connection. QoS is supported to secure the
bandwidth for some bandwidth-demanded applications including VoIP or
videoconference. The 802.3x and backpressure flow control mechanisms
are also supported to ensure the correctness of data transmitting. Speed,
duplex mode auto-detection is also supported for your convenient
installation.
Key Features
16/24 fixed 10/100Mbps Fast Ethernet ports for easy network connecting
application.
Provide 4K MAC address entries and 16/24 groups VLAN table
Support Port Mirror.
Support up to 4 ports and 2 groups port aggregation.
Support QoS for better communication quality.
Support full duplex flow control and half duplex back pressure
Store-and-forward forwarding scheme
Error packet filtering
1.5M bits buffer Memory
Support Web-based management interface.
FCC Class A, CE, VCCI. Meet RoHS.

6
D316S / D324S Front Panel
The front panel consists of LED indicators. Please refer to the following
paragraph for information.
LEDs Definition
LED for the device:
The switch provides a power LED for the device.
LED Status Operation
Power Steady Green The switch is powered on
Off The switch is powered off
LED for each port:
LED Status Operation
LINK/ACT
Green The port is connected.
Blinking Green A valid link is established, and there is data
transmitting/receiving.
Off No valid link on this port.
Port Operation
The auto-negotiation feature allows those ports running at one of the

7
following operation modes:
Media Speed Duplex Mode
10/100Mbps(copper) 10Mbps Full Duplex
Half Duplex
100Mbps
Full Duplex
Half Duplex
Restore Default Button
You can use this button to reset the switch or restore factory default settings.
To reset the switch, press the button once.
To restore factory default settings, press and hold the button for three
seconds.
The Rear Panel
Power Receptacle
To be compatible with the electric service standards around the world, the
switch is designed to afford the power supply in the range from 100 to
240VAC, 50/60Hz. Please make sure that your outlet standard to be within
this range.
To power on the switch, please plug the female end of the power cord firmly
into the receptacle of the switch and the other end into an electric service
outlet. After the power cord installation, please check if the power LED is lit
for a normal power status.

8
Installation
This switch can be placed on your desktop directly, or mounted in a rack.
Please refer to the instructions for installation.
Before installing the switch, we recommend:
1. The switch is placed with appropriate ventilation environment. A
minimum 25mm space around the unit is recommended.
2. The switch and the relevant components are away from sources of
electrical noise such as radios, transmitters and broadband amplifiers
3. The switch is away from environments beyond recommend moisture
Desktop Installation
1. Install the switch on a level surface that can support the weight of the
unit and the relevant components.
2. Plug the switch with the female end of the provided power cord and plug
the male end to the power outlet.
Rack-mount Installation
The switch may be standalone, or mounted in a rack. Rack mounting
facilitate to an orderly installation when you are going to install series of
networking devices.
Procedures to Rack-mount the Switch:
1. Disconnect all the cables from the switch before continuing.
2. Place the unit the right way up on a hard, flat surface with the front
facing you.
3. Locate a mounting bracket over the mounting holes on one side of the
unit.
4. Insert the screws and fully tighten with a suitable screwdriver.
5. Repeat the two previous steps for the other side of the unit.
6. Insert the unit into the rack and secure with suitable screws.
7. Reconnect all the cables.

9
Installing Network Cables
1. Crossover or straight-through cable: All the ports on the switch
support Auto-MDI/MDI-X functionality. Both straight-through or
crossover cables can be used as the media to connect the switch with
PCs as well as other devices like switches, hubs or router.
2. Category 3,4,or 5 cable: To make a valid connection and obtain the
optimal performance. An appropriate cable that corresponds to different
transmitting/receiving speed is required. To choose a suitable cable,
please refer to the following table.
Media Speed Wiring
10/100Mbps copper
10Mbps Category 3,4,5 Utp/STP
100Mbps Category 5 UTP/STP

10
Functional Description
Flow Control and Back Pressure
Flow control and Back Pressure both contributes for lower and higher speed
devices to communicate to each other hence ensures the correctness of
data transmitting. The 802.3x flow control and Back Pressure mechanisms
work respectively for full and half duplex modes. Flow control can be
enabled or disabled on a per-port basis.
Mirror
The Mirror function provides network administrator to monitor the traffic. By
forwarding a copy of the packets that transferred by the monitored port, the
sniffer port received all the packets and hence is able to monitor the traffic
of the specified port.
VLAN
With VLAN supported, the network can be segmented in groups to reduce
the collisions from widely broadcasting. The device supports port-based
VLAN.Port-based VLAN classifies incoming packets to VLANs according to
their ingress port.
Trunk (Aggregation)
The Trunk functionality integrates several ports to enlarge the bandwidth
that helps to boost the backbone connectivity. The switch allows the
Maximum 2 group and 4 members for each group.
Quality of Service (QoS)
The QoS service classifies packets into different precedence. The packets
are transmitted and received by their classified priorities. This mechanism
helps high bandwidth demanded applications such as VoIP to get an
unobstructed connection.
Otros manuales para D316S
1
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Cambiar de Datasheen