Turning the Lights On
To turn the lights on, press
and hold
(and enter code if required).
Do this to the Slave, then the
Master.
The Master and the Slave
controllers will begin to
establish a radio link as
indicated by the TX and RX
green lights on the controllers.
Both lights will show Flashing
Yellow aspects and progress to
showing RED aspects.
Also, the Controllers will complete a self-diagnosis and check any connected external
equipment such as the optional vehicle detectors.
If is activated, the Controller will wait for further input and all connected traffic
lights will display Flashing Yellow when End OPERATION is selected.
The message: SYSTEM OPERATING will be displayed.
You can select to End OPERATION by selecting the & buttons, or press to
keep the Lights operating in the background while you make changes on the fly such as
Light timing, Auto return type, change Manual to Auto or Demand Modes, or most other
menu items.
Press the button to exit the selected MENU and return to the main screen.
After PROGRAM MODE selections are made, press either or buttons to resume
normal operation.
To turn the lights off, press and hold the
button.
Note the controller will remain on as indicated by a slow pulse on the POWER indicator.
(And continue to communicate with DS-Live if a DataSign SIM Card is fitted).
RED
TIME
SET
GREEN
TIME
SET
YELLOW
TIME
SET
MASTER SLAVE
PROGRAM
MENU
MAST ER, MODE SELECT
DEMAND
(VEHICLE
SENSE)
AUTO
(TIMED)
PLANT
SHUTTLE
PTL CONTROLLER NX-G
© 2022. Designed & manufactured by Data Signs Pty. Ltd. www.datasigns.com.au
LAB 0014AB Issue 4.
N30333
GO
STOP
ON / OFF
GO
STOP
ENTERCLEAR
1
4
7
2
5
8
0
3
6
9
MASTER USE ONLY
LINK
POWER TX RX
REMOTE
ACTIVE
DEMAND
SLAVE DISPLAY SELECT
MANUAL
FLASH
The Controllers will start up in the last mode that was set.