SI-32 INTERFACE
DISPLAY MANUAL
P1146
28 February 2018
ED-10606
Rev 5

Copyright © 2018
All rights reserved. While every precaution has been taken in the preparation of this manual, the publisher assumes no
responsibility for errors or omissions. No part of this book covered by the copyrights hereon may be reproduced or copied
in any form or by any means—graphic, electronic, or mechanical, including photocopying, taping, or information
storage and retrieval systems—without written permission of the publisher.
Daktronics trademarks are property of Daktronics, Inc. All other trademarks are property of their respective companies.

– i –
Table of Contents
1 Introduction.........................................1
How to Use This Manual ............................1
Product Description...................................2
Denitions ...................................................2
2 Mechanical and Electrical
Installation ...........................................4
Mechanical Installation ............................4
Computer to SI-32 Connections ..............4
RS232 System ..........................................4
RS422 System ..........................................5
Switches to SI-32.....................................6
SPST .......................................................6
SPDT ......................................................7
Momentary ..........................................7
BCD (Binary Coded Decimal) ...........8
Rotary ...................................................9
3 Version 3 Software Operation..........10
Using the Venus®1500 Version 3 Software.
...................................................................10
Using the Switch Interface......................10
SI-32 Mode Setup ..............................12
Toggle Mode .....................................12
SPST Switch .........................................12
SPDT Switch ........................................12
Momentary Mode ...................................13
BCD Mode (Binary Coded Decimal) ....13
Connecting Two SI-32 Units ....................14
SI-32 Setup ................................................14
4 Version 4 Software Operation..........15
Using the Venus®1500 Version 4 Software
...................................................................15
Using the Switch Interface......................15
SI-32 Mode Setup .................................16
Toggle Mode.........................................16
SPST Switch ............................................16
SPDT Switch............................................16
Momentary Mode ...................................17
BCD Mode (Binary Coded Decimal) ....17
Connecting Two SI-32 Units ....................18
SI-32 Setup ................................................18
5 Maintenance and Troubleshooting ....
............................................................19
Getting Started ........................................19
Technical Specications .........................19
LED Functions ...........................................19
Routine/Preventative Maintenance .....20
Troubleshooting .......................................21
Replacements Parts List ..........................22
Daktronics Exchange and Repair &
Return Programs ......................................22
Exchange Program ..............................22
Repair & Return Program .....................23
Shipping Address..................................23
Email ......................................................23
A Reference Drawings .........................25

– ii –
This page intentionally left blank.
– ii –

Introduction
1
1 Introduction
Reference Drawings:
System Riser Diagram: Single Pole (SP)............................................................. DWG-093476
System Riser Diagram: Momentary................................................................... DWG-096221
System Riser Diagram: BCD Switch................................................................... DWG-096315
System Riser Diagram: Rotary............................................................................ DWG-097099
How to Use This Manual
This manual explains the installation, operation, maintenance, and troubleshooting of
the SI-32 (Switch Interface - 32 Input). For questions regarding the safety, installation,
operation, or service of this system, please refer to the telephone numbers listed on the
cover page of this manual.
Important Safeguards:
1. Read and understand these instructions before installing.
2. Do not drop the SI-32 or allow it to get wet.
3. Be sure the display is properly grounded.
4. Disconnect power to the sign when it is not in use.
5. Disconnect power when servicing the sign.
The manual contains ve sections: Introduction, Mechanical and Electrical Installation,
Operation, Maintenance and Troubleshooting, and Reference Drawings.
• Introduction covers the basic information needed to make the most of the rest
of this manual. Take time to read the entire introduction as it denes terms and
explains concepts used throughout the manual.
• Mechanical and Electrical Installation provides general guidance on terminating
power and signal cable at the sign.
• Operation provides general information on using the Venus®1500 Software with
the Switch Interface, and the type of switch modes.
• Maintenance and Troubleshooting addresses such topics as care of the unit,
troubleshooting the unit, and performing general maintenance.
• Reference Drawings includes the drawings referenced in this manual.
Daktronics identies manuals by the ED or DD number located on the cover page of
each manual. For example, this manual is referred to as ED-10606.
Figure 1 illustrates Daktronics’ drawing numbering system. This number is located in the
lower-right corner of the drawing. The manual refers to drawings by listing the last ve
digits and the letter preceding them. In the example below, the drawing would be
referred to as DWG-069945.
Figure 1: Drawing Label

Introduction
2
Product Description
The SI-32 is a 32 input message selector for Daktronics DataTracTM and Galaxy®displays.
This unit provides 32 optically isolated inputs. Two SI-32 units can be chained together to
provide for a total of 60 isolated inputs.
The 32 input switch interface (SI-32) controls what preprogrammed messages, created
using the Venus®1500 Software, appear on the display. These messages must exist at
the display for the SI-32 to run them. Refer to the proper display manual for questions
regarding the display. Refer to the Venus®1500 Software Manual for information on
message editing.
Denitions
BCD: A BCD (Binary Coded Decimal) is a switch with multiple contacts. When a number is
selected, the corresponding BCD combination of contacts is closed.
Momentary: Momentary is a type of switch with two terminals and one movable contact.
When the switch is depressed, the contact closes the two terminals. When the switch is
released, the contact opens the two terminals
Network: A network consists of multiple displays connected to each other. Up to 240
Venus®1500 controlled displays can exist on one network.
RS232: RS232 is a standard PC communication type with a maximum cable length of 25
feet (7.62 meters).
RS422: RS422 is a standard differential communication type with a maximum cable
length of 4000 feet (1.2 kilometers).
Sign Address: The sign address is an identication number assigned to each sign of a
network. The Venus®1500 Software uses the address to locate and communicate with
each display. Signs on the same network cannot use the same address.
SPDT: A SPDT (Single Pole, Double Throw) is a type of switch action found on many types
of switches. A SPDT switch has three (3) terminals and one movable contact that make a
connection between two (2) terminals at a time. A SPDT switch controls two circuits.
Figure 2: SI-32 Switch Interface

Introduction
3
SPST: A SPST (Single Pole, Single Throw) is a type of switch action found on many types
of switches. A SPST switch has two (2) terminals and one movable contact that make a
connection between terminals when switched on. A SPST switch controls one circuit.
Venus®1500 Version 3 Software: The Venus®1500 Version 3 Software is a Daktronics
designed, Windows®based software used to make and edit display messages. The
Venus®1500 operating Version 3 software requires Windows®98, NT 4.0, Windows®2000, or
Windows®XP Home/Professional with the most current updates installed.
Venus®1500 Version 4 Software: The Venus®1500 Version 4 Software is a Daktronics
designed, Windows®based software used to make and edit display messages. The
Venus®1500 operating Version 4 software requires Windows®XP Home/Professional,
Windows®Vista™, or Windows®7 with the most current updates installed.

Mechanical and Electrical Installation
4
2 Mechanical and Electrical Installation
Reference Drawings:
System Riser: Signal Pole .................................................................................... DWG-093476
System Riser: Momentary................................................................................... DWG-096221
System Riser: BCD Switch ................................................................................... DWG-096315
System Riser: Rotary............................................................................................ DWG-097099
OSI-32 Wiring Diagram ....................................................................................... DWG-097134
Mechanical Installation
The switch interface should be
mounted near the operator. It
can be placed on a desktop
or hung from a wall nearby.
Refer to Figure 3 for the
mounting hole conguration
on the back of the interface.
Computer to SI-32
Connections
RS232 System
A RS232 system connects the
SI-32 directly to the computer
with an adapter.
1. Plug the 9-pin or 25-
pin DB to RJ11 adaptor
(depending on your PC) to
the PC’s RS232 serial COM
port.
2. Plug one end of the phone cable into the adapter and the opposite end into the
“RS232 IN” jack on the SI-32.
3. Indoor Displays: Use a ipped 24 AWG phone cable to connect the display to the
RS422 output (J3).
Figure 3: Switch Interface Mounting Hole Locations

Mechanical and Electrical Installation
5
4. Outdoor displays: Use a 6-conductor cable from the SI-32 (TB9) to the RS422 IN at the
display. The signal cable will be wired one-to-one from the SI-32 to the display input.
(See your display installation manual for RS422 input location.)
5. Connect additional displays as described in the display’s installation manual.
RS422 System
A RS422 system requires a signal converter to connect the SI-32 to the computer. This
provides up to 4000 feet between the SI-32 and the computer.
1. Plug the serial cable’s DB25 pin connector into the signal converter.
2. Plug the DB9 connector into the RS232 COM port being used. If your computer has a
DB25, use the DB9 to DB25 adaptor.
3. Plug the signal converter’s power cord into a 120 VAC grounded outlet.
4. Plug a ipped phone cable into the “RS422 OUT” (J2) of the signal converter and the
opposite end into the “RS422 IN” (J2) of the SI-32.
5. Indoor Displays: Use a ipped 24 AWG phone cable to connect the display to the
RS422 output (J3).
Figure 4: RS232 Layout

Mechanical and Electrical Installation
6
6. Outdoor displays: Use a 6-conductor cable from the SI-32 (TB9) to the RS422 IN at the
display. The signal cable will be wired one-to-one from the SI-32 to the display input.
(See your display installation manual for RS422 input location.)
7. Connect additional displays per your display’s installation manual.
Switches to SI-32
The switches are NOT supplied by Daktronics.
Note: Each switch input has a P and an N connection, which are connected to an
internal +5V and ground respectively.
Note: Set the DIP switch to the correct setting before powering up the switch
interface. The switch setting is only recognized on boot-up. If you change the
switch setting, recycle power to the unit.
SPST
Each SPST switch connects to
one switch input and controls
one message. Refer to the OSI-
32 Wiring Diagram.
1. Connect one N.O.
(Normally Open) terminal
of the SPST switch to SW1-P
and connect the other C
(Closed) terminal to SW1-N
as shown in Figure 6.
2. Connect all other SPST
switches per Step 1.
Figure 5: RS422 Layout
Figure 6: SPST Mode Connection (Toggle Switch Shown)