Daikin BRC1E51A7 Manual de usuario

Be sure to read this installation manual before
conducting the installation of this product.
MODEL BRC1E51A7
WIRED REMOTE
CONTROLLER
INSTALLATION MANUAL
00_CV_EM08A086_EN.indd 100_CV_EM08A086_EN.indd 1 4/7/2009 7:31:25 PM4/7/2009 7:31:25 PM


English 1
Contents
1. Safety Precautions ............................ 2
2. Accessories ....................................... 4
3. Remote controller installation
procedure .......................................... 4
4. Functions and menu items
of remote controller buttons .......... 10
5. Power-on .......................................... 12
6. Field setting method ....................... 13
7. Test operation method
(in the case of SkyAir) .................... 16
8. Checking procedure of
error record ..................................... 19
9. Registration method of the
service contract .............................. 20
10. Confirmation of registered
details ............................................... 21
11. Clock Setting ................................... 22
12. Language changeover .................... 22
01_EN_EM08A086.indd 101_EN_EM08A086.indd 1 4/7/2009 7:32:06 PM4/7/2009 7:32:06 PM

2 English
Safety Precautions1.
Also see installation manual attached to the indoor unit.
Please read these “Safety Precautions” carefully before installing air conditioning
equipment and be sure to install it correctly.
The precautions described herein are classified as WARNING and CAUTION. They both contain●
important information regarding safety. Be sure to observe all precautions without fail.
WARNING Failure to follow these instructions properly may result in personal
injury or loss of life.
CAUTION
Failure to observe these instructions properly may result in property
damage or personal injury, which may be serious depending on the
circumstances.
After completing installation, conduct a trial operation to check for faults and explain to the customer●
how to operate the air conditioner and take care of it with the aid of the operation manual. Ask the
customer to store the installation manual along with the operation manual for future reference.
WARNING
Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the remote controller yourself. Improper installation may result in water
leakage, electric shocks or fire.
Consult your local dealer regarding relocation and reinstallation of the remote controller.
Improper installation work may result in leakage, electric shocks or fire hazards.
Install the remote controller in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the unit falling, water leaakage, electric shocks or fire.
Install the remote controller on a foundation strong enough to withstand the weight of the remote
controller.
A foundation of insufficient strength may result in the remote controller falling and causing injury.
Electrical work must be performed in accordance with relevant local and national regulations and
with instructions in this installation manual.
Be sure to use a dedicated power supply circuit only. Insufficiency of power circuit capacity and
improper workmanship may result in electric shocks or fire.
Always perform installation work with the power supply shut-off.
Touch with energized electric parts causes an electric shock.
Do not disassembly, reconstruct or repair.
Electric shock and/or fire are caused.
Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the
terminal connections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
The choice of materials and installations must comply with the applicable national and international
standards.
01_EN_EM08A086.indd 201_EN_EM08A086.indd 2 4/7/2009 7:32:06 PM4/7/2009 7:32:06 PM

English 3
CAUTION
To avoid leakage and electric shock due to entry of water or insects, fill the wiring through hole with
putty.
To avoid electric shocks, do not operate with wet hands.
Do not wash the remote controller with water, as this may result in electric shocks or fire.
Install the indoor and outdoor units, power cord and connecting wires at least 1 meter away from
televisions or radios to prevent picture interference and noise.
(Depending on the incoming signal strength, a distance of 1 meter may not be sufficient to eliminate
noise.)
Do not install the air conditioner in the following locations:
Where there is a high concentration of mineral oil spray or vapour (e.g. a kitchen).1.
Plastic parts will deteriorate, parts may fall off and water leakage could result.
Where corrosive gas, such as sulphurous acid gas, is produced.2.
Corroding of copper pipes or soldered parts may result in refrigerant leakage.
Near machinery emitting electromagnetic radiation.3.
Electromagnetic radiation may disturb the operation of the control system and result in a
malfunction of the unit.
Where flammable gas may leak, where there is carbon fibre or ignitable dust suspensions in the4.
air, or where volatile flammables such as paint thinner or gasoline are handled.
Operating the unit in such conditions may result in fire.
High temperature area or directly flamed point.5.
Heating and/or firing may be caused.
Moist area, or place where may be exposed to water.6.
If water enters inside of the remote controller, electric shock may be caused and inner electronics
may fail.
When remote controller thermo function is used, select the installation location considering the
followings.
A place where average temperature in the room can be detected.●
A place where is not exposed to direct sunlight.●
A place where is far apart from heat source.●
A place where is not affected by outside air due to door opening/closing or the like.●
01_EN_EM08A086.indd 301_EN_EM08A086.indd 3 4/7/2009 7:32:06 PM4/7/2009 7:32:06 PM

4 English
Accessories2.
The following accessories are included.
Wood screw Small screw Clamp Manual CD Quick
Reference Wiring retainer
(φ3.5×16) (M4×16)
(2 pcs.) (2 pcs.) (1 pc.) (1 pc.) (1 pc.) (1 pc.)
Remote controller installation3.
procedure
Determine where to install the remote controller.3-1
Make sure to follow “ 1. Safety Precautions” when determining the location.
Make a wiring through hole on the wall if the wires are taken3-2
out from the back side.
Set the center of the wall hole
to the center of the wiring thro
ugh hole on the controller
lower case when making the
hole.
F8-10
External view of the remote controller
Through
hole
F8-10
Lower case
Through hole
48.5
40
Remove upper case.3-3
Insert a screwdriver in the recess of lower case to remove the upper case (2 points).
Upper case
Lower case
Screwdriver
Insert and twist the screwdriver
lightly for removal.
Remote controller PC-board is
installed on the upper case. Take care
not to damage the PC-board with the
screwdriver.
Take care that dust or moisture does
not touch the PC-board of removed
upper case.
If the hole size is too large or the location is not
proper, the hole may come out from the controller.
CAUTION
01_EN_EM08A086.indd 401_EN_EM08A086.indd 4 4/7/2009 7:32:07 PM4/7/2009 7:32:07 PM

English 5
Determine the direction of controller wiring outlet (back3-4
outlet, left outlet, upper center outlet, upper outlet).
Back outlet3-4-1 Left outlet3-4-2
Cut off resin area (hatched area). Cut off thin area (hatched area) with nippers
or the like, and then remove burr with a file or
the like.
Upper outlet3-4-3 Upper center outlet3-4-4
Cut off thin area (hatched area) with nippers
or the like, and then remove burr with a file or
the like.
Cut off thin area (hatched area) with nippers
or the like, and then remove burr with a file or
the like.
Conduct wiring.3-5
1. Switch box and transmission wiring are not attached.
Do not directly touch the remote controller PC-board.2.
CAUTION
Wiring Specifications
Wiring Type Sheathed vinyl cord or cable
Wiring Size 0.75-1.25mm²
01_EN_EM08A086.indd 501_EN_EM08A086.indd 5 4/7/2009 7:32:08 PM4/7/2009 7:32:08 PM

6 English
Sheath part in the remote controller case should be stripped.
Peel the shield and sheath
Cutting guideline
of the wiring
Ca. 10mm
For easy wiring, it is better to
keep ca. 10mm difference
between the length of two wires.
Sheath stripping length:
Ca. 150mm for upper outlet●
Ca. 200mm for upper center outlet●
Connect the terminals (P/P1, N/P2) of the remote controller upper case with the terminals (P1, P2)
of the indoor unit. (P1 and P2 have no polarities.)
Back outlet3-5-1
<Wiring fixing guideline>
Lower case
P1
Indoor unit
P2
Upper case
PC-board
Clamp
Wiring fixing
point
Cross-section -
Secure the wiring at
the wiring fixing point
by using attached
clamping material.
Clamp
01_EN_EM08A086.indd 601_EN_EM08A086.indd 6 4/7/2009 7:32:09 PM4/7/2009 7:32:09 PM

English 7
Left outlet3-5-2
PC-board
Lower case
Upper case
Indoor unit
P1P2
Upper outlet3-5-3
Install attached
wiring retainer to
prevent wiring pinch
according to left
figure.
PC-board
Indoor unit
Wiring retainer
Wiring retainer
Upper case
Lower case
Upper case
Wiring
Cross-section -
P1P2
Upper center outlet3-5-4
PC-board
Indoor unit
Wiring retainer
Upper case
Lower case
P1P2
01_EN_EM08A086.indd 701_EN_EM08A086.indd 7 4/7/2009 7:32:09 PM4/7/2009 7:32:09 PM

8 English
●Perform wiring apart from a power line not to receive electrical noise (external noise)
during the wiring.
Seal wiring draw-in port securely with putty (field supply) to prevent entry of insects or●
the like.
CAUTION
Fixing procedure of lower case.3-6
In the case of wiring center upward drawing or rearward drawing, see wiring procedure first as
wiring with the case is needed before fixing.
In the case of installation on the wall3-6-1
Secure by using attached wood screws (2 pcs.).
Wood screws
(F3.5×16)
In the case of installation on the switch box3-6-2
Secure by using attached small screws (2 pcs.).
Small screws (M4×16)
Switch box
(field supply)
(Use optional accessory
KJB211A)
Switch box for two units
(with no cover)
84
46
(Installation pitch)
01_EN_EM08A086.indd 801_EN_EM08A086.indd 8 4/7/2009 7:32:11 PM4/7/2009 7:32:11 PM
Tabla de contenidos
Otros manuales de Enrutador de red de Daikin
Manuales populares de Enrutador de red de otras marcas

NETGEAR
NETGEAR FS526T - Switch Manual de usuario

Korenix
Korenix JetNet 5710G Series Manual de usuario

Automated Logic
Automated Logic ZN551 Manual del propietario

Cisco
Cisco ASR 1000 Series Manual del operador

EnGenius
EnGenius ESR-9710 Manual de usuario

Cisco
Cisco 805 Series Instrucciones de funcionamiento y seguridad