cytiva CU-950 Manual de usuario

1 Introduction
Purpose of the Installation guide
This instruction describes CU-950 and provides information on how to install it with
ÄKTAexplorer, ÄKTAFPLC, ÄKTAmicro, ÄKTApilot™ and ÄKTApurifier.
Prerequisites
In order to operate CU-950 safely and according to the intended purpose the following
prerequisites must be met:
•You must read the Safety Instructions in this Installation guide.
•The system should be installed according to the instructions in this Installation
guide.
In this chapter
This chapter contains important user information and regulatory information.
1 Introduction
2 CU-950 Installation guide 11000325 AH

1.1 Important user information
Read this before using or installing
CU-950
All users must read the safety instructions in this Installation guide before installing,
using or maintaining the system.
Do not operate CU-950 in any other way than described in the user documentation. If
you do, you may be exposed to hazards that can lead to personal injury and you may
cause damage to the equipment.
Intended use
CU-950 is intended for research use only, and shall not be used in any clinical or in vitro
procedures for diagnostic purposes.
Definitions
This user documentation contains safety notices (WARNING, CAUTION, and NOTICE)
concerning the safe use of the product. See definitions below.
WARNING
WARNING indicates a hazardous situation which, if not avoided,
could result in death or serious injury. It is important not to proceed
until all stated conditions are met and clearly understood.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury. It is important not to
proceed until all stated conditions are met and clearly understood.
NOTICE
NOTICE indicates instructions that must be followed to avoid
damage to the product or other equipment.
1 Introduction
1.1 Important user information
CU-950 Installation guide 11000325 AH 3

Notes and tips
Note: A note is used to indicate information that is important for trouble-free and
optimal use of the product.
Tip: A tip contains useful information that can improve or optimize your
procedures.
Typographical conventions
Software items are identified in the text by bold italic text.
Hardware items are identified in the text by bold text.
In electronic format, references in italics are clickable hyperlinks.
1 Introduction
1.1 Important user information
4 CU-950 Installation guide 11000325 AH

1.2 Regulatory information
This section lists the directives and standards that are fulfilled by CU-950.
Contact information for support
To find local contact information for support and sending troubleshooting reports, visit
cytiva.com/contact.
Manufacturing information
The table below summarizes the required manufacturing information.
Requirement Information
Name and address of manufacturer Cytiva Sweden AB
Björkgatan 30
SE 751 84 Uppsala
Sweden
Telephone number of manufacturer + 46 771 400 600
Conformity with EU Directives
See the EU Declaration of Conformity for the directives and regulations that apply for
the CE marking.
If not included with the product, a copy of the EU Declaration of Conformity is available
on request.
CE marking
The CE marking and the corresponding EU Declaration of Conformity is valid for the
instrument when it is:
•used according to the Operating Instructions or user manuals, and
•used in the same state as it was delivered, except for alterations described in the
Operating Instructions or user manuals.
Regulatory compliance of connected
equipment
Any equipment connected to CU-950 should meet the safety requirements of EN
61010-1/IEC61010-1 or relevant harmonized standards. Within the European Union,
connected equipment must be CE-marked.
1 Introduction
1.2 Regulatory information
CU-950 Installation guide 11000325 AH 5

1.3 Description
CU-950 unit consists of a rear panel with connectors and three indicators (LEDs) on the
front. The unit is supplied with a small power converter and EU and US mains cables.
USB UniNet-1 Test
1
23
45
6
7
8
9
Figure 1.1: CU-950 unit.
Table 1.1: Main parts of CU-950 unit.
Part Description
1 Attachment
2 Power input
3 USB port
4 Ethernet port
5 UniNet-1 cable port
6 Test port
7POWER lamp, is on when connected to mains power
8PC lamp, blinks at first and then remains on when communication with
the PC is established
9SYSTEM lamp, blinks and then remains on when communication with
ÄKTA™ system has been established.
1 Introduction
1.3 Description
6 CU-950 Installation guide 11000325 AH

2 Safety instructions
This chapter describes the safety compliance, safety labels, general safety
precautions, emergency procedures, power failure and recycling of CU-950.
2 Safety instructions
CU-950 Installation guide 11000325 AH 7

2.1 Safety precautions
CU-950 is powered by mains voltage that may be hazardous. Before installing
operating or maintaining the system, you must be aware of the hazards described in
this manual.
Follow the instructions provided to avoid personal injury or damage to the
equipment.
General precautions
WARNING
Always follow these safety precautions to avoid injury when using
the CU-950 instrument.
Installation
WARNING
CU-950 shall be installed and prepared by personnel authorized by
Cytiva.
WARNING
CU-950 is not designed for use in an environment where explosion-
proof equipment is required.
WARNING
Protective ground. The CU-950 power converter must always be
connected to a grounded power outlet.
WARNING
Supply voltage. Make sure that the supply voltage at the wall
outlet corresponds to the marking on the power converter, before
connecting the power cord. Failure to do this may cause injury to
personnel and damage to the system.
2 Safety instructions
2.1 Safety precautions
8 CU-950 Installation guide 11000325 AH

CAUTION
CU-950 is designed for indoor use only.
CAUTION
Do not use CU-950 in a dusty atmosphere or close to spraying
water.
System operation
WARNING
Operation and user maintenance of CU-950 should be performed
by properly trained personnel only.
WARNING
Do not operate CU-950 in any other way than described in the
CU-950 and UNICORN manuals.
WARNING
Do not use CU-950 if it is not working properly, nor if it has suffered
any damage, for example:
•Damage to the power cord or its plug
•Damage caused by dropping the equipment
•Damage caused by splashing liquid onto it
Maintenance
WARNING
Electrical shock hazard. All repairs should be done by service
personnel authorized by Cytiva. Do not open any covers or replace
parts unless specifically stated in the user documentation.
2 Safety instructions
2.1 Safety precautions
CU-950 Installation guide 11000325 AH 9

WARNING
Do not use any accessories or products not supplied or
recommended by Cytiva.
WARNING
Do not remove any protection devices from the system.
2 Safety instructions
2.1 Safety precautions
10 CU-950 Installation guide 11000325 AH
Tabla de contenidos
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario












