CYP CDPS-CS7-S Manual de usuario

CDPS-CS7-S
IP Master Controller (SDVoE)
(Phase 1)
Operation Manual
Operation Manual


DISCLAIMERS
The information in this manual has been carefully checked and
is believed to be accurate. Cypress Technology assumes no
responsibility for any infringements of patents or other rights of third
parties which may result from its use.
Cypress Technology assumes no responsibility for any inaccuracies
that may be contained in this document. Cypress also makes no
commitment to update or to keep current the information contained
in this document.
Cypress Technology reserves the right to make improvements to this
document and/or product at any time and without notice.
COPYRIGHT NOTICE
No part of this document may be reproduced, transmitted,
transcribed, stored in a retrieval system, or any of its part translated
into any language or computer le, in any form or by any means—
electronic, mechanical, magnetic, optical, chemical, manual, or
otherwise—without express written permission and consent from
Cypress Technology.
© Copyright 2018 by Cypress Technology.
All Rights Reserved.
TRADEMARK ACKNOWLEDGMENTS
All products or service names mentioned in this document may be
trademarks of the companies with which they are associated.

SAFETY PRECAUTIONS
Please read all instructions before attempting to unpack, install or
operate this equipment and before connecting the power supply.
Please keep the following in mind as you unpack and install this
equipment:
• Always follow basic safety precautions to reduce the risk of re,
electrical shock and injury to persons.
• To prevent re or shock hazard, do not expose the unit to rain,
moisture or install this product near water.
• Never spill liquid of any kind on or into this product.
• Never push an object of any kind into this product through any
openings or empty slots in the unit, as you may damage parts
inside the unit.
• Do not attach the power supply cabling to building surfaces.
• Use only the supplied power supply unit (PSU). Do not use the PSU
if it is damaged.
• Do not allow anything to rest on the power cabling or allow any
weight to be placed upon it or any person walk on it.
• To protect the unit from overheating, do not block any vents or
openings in the unit housing that provide ventilation and allow for
sufcient space for air to circulate around the unit.
• Please completely disconnect the power when the unit is not in
use to avoid wasting electricity.
REVISION HISTORY
REVISON DATE SUMMARY OF CHANGE
RDV1 2019/05/09 Preliminary release

CONTENTS
1. Introduction......................................................1
2. Applications.....................................................1
3. Package Contents ..........................................2
4. System Requirements......................................2
5. Features............................................................2
6. Operation Controls and Functions.................3
6.1 Front Panel ................................................. 3
6.2 Rear Panel.................................................. 3
6.3 Remote Control......................................... 4
6.4 IR Cable Pinout.......................................... 5
6.5 RS-232 Pinout and Defaults ...................... 5
6.6 WebGUI Control ........................................ 6
6.6.1 Monitor & Control Tab..................... 8
6.6.2 System Tab...................................... 17
6.6.3 Settings Tab .................................... 19
6.6.4 Transmitter Tab ............................... 19
6.6.5 Receiver Tab .................................. 22
6.6.6 Scaling Tab ..................................... 25
6.6.7 Video Wall Tab ............................... 26
6.6.8 MultiView Tab ................................. 28
6.7 Telnet Control .......................................... 30
6.8 RS-232 and Telnet Commands .............. 31
7. Connection Diagram ....................................38
8. Specications ................................................39
8.1 Technical Specications ........................ 39
9. Acronyms .......................................................40

1
1. INTRODUCTION
This IP Master Controller is a powerful and exible solution for
controlling multiple SDVoE (Software Dened Video over Ethernet)
based extenders within same network. The user only needs to install
this unit into the same local network as the extenders (Transmitter and
Receiver) to easily dene and congure channel routing selections
(including video, audio, and a variety of control interface types) using
the WebGUI. Without the use of this centralized control unit, each
Transmitter and Receiver pair would only be able to function in a
point-to-point capacity.
Additionally, this unit supports controlling and conguring the matrix,
video wall, and multiviewer modes of connected SDVoE units. The
settings of all connected Transmitter/Receiver units, including IP
address, netmask and extender status are clearly displayed within
the WebGUI. A trigger input interface is also provided to allow the
easy addition of a remote control keypad, or other trigger-supporting
products, which can be installed within a podium or within a table in
a conference room or classroom. This interface can allow the user to
activate stored presets with the simple press of a button. Standard
control is available via WebGUI (remote or local), RS-232, Telnet and IR
Remote.
2. APPLICATIONS
• Video/TV wall display and control
• Security surveillance and control
• Commercial advertising, display and control
• Home Theaters with Smart Home Controls
• Retail sales and demonstration

2
3. PACKAGE CONTENTS
• 1× IP Master Controller (SDVoE)
• 1× 5V/2.5A DC Power Adapter
• 1× Terminal Block (3-pin)
• 3× Terminal Block (5-pin)
• 1× IR Extender Cable
• 1× Remote Control (CR-183)
• 1× Shockproof Feet (Set of 4)
• 1× Operation Manual
4. SYSTEM REQUIREMENTS
• An active network connection from a switch or router for control of
compatible Video over IP devices.
5. FEATURES
• Enables the management and conguration of multiple compatible
SDVoE (Software Dened Video over Ethernet) extenders through a
single WebGUI
• Provides control over the independent routing of video, audio
and control signals between all local compatible transmitters and
receivers
• Control over matrix, video wall, and multiviewer modes using
WebGUI presets
• WebGUI clearly displays the status of all connected Transmitters and
Receivers, including IP address, channel selection, etc.
• Can generate serial commands to directly control an external serial-
controllable device
• Can be powered by Ethernet switches supporting the IEEE 802.3af
2003 PoE standard (Optional)
• Trigger Control Keypad support for easy, single-button, preset
activation (Optional, coming in the “Phase 2” update)
• Standard control is available via WebGUI (remote or local), RS-232,
Telnet, and IR Remote

3
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Front Panel
POWER IR
IP Master Control
1 2
1POWER LED: This LED will illuminate to indicate the unit is on and
receiving power.
2IR Window: Accepts IR signals from the included IR remote for
control of this unit only.
6.2 Rear Panel
LAN 1(POE)LAN 2USBHDMI OUTRS-232CONTROLIR EXT DC 5V
TRIGGER IN
TX RX
1 2 3 4 5 6 7 8 109
1IR EXT Port: Connect to the provided IR Extender to extend the
IR control range of the unit. Ensure that the remote being used is
within direct line-of-sight of the IR Extender.
2CONTROL Terminal Block: Connect to a serial controllable device
for the transmission of RS-232 signals.
3RS-232 Terminal Block: Connect to a PC, laptop or other serial
control device with a 3-pin adapter cable to control the unit via
RS-232.
4TRIGGER IN Terminal Block: This functionality is not currently
available and will be added in the “Phase 2” update.
5HDMI OUT Port: This functionality is not currently available and will
be added in the “Phase 2” update.
6USB Port: This functionality is not currently available and will be
added in the “Phase 2” update.

4
7LAN 2 Port: Connect directly, or through a network switch, to your
PC/ laptop to control the unit via WebGUI/Telnet.
8LAN 1(POE) Port: This port is used to connect to the SDVoE devices
to be controlled. Connect to the SDVoE units’ private network
through their dedicated network switch, to enable detection and
control over those units.
Note: If the connected network switch supports the IEEE 802.3af
2003 PoE (Power over Ethernet) standard, this unit can optionally
be powered directly via this Ethernet port.
9FACTORY RESET Pinhole: Press and hold for 3 seconds to reset the
unit to its factory defaults, including Ethernet settings.
Note: While the reset is in process, the LEDs on the front of the unit
will ash. Once the reset is complete, the unit will return to normal
operation.
10 DC 5V Port: Plug the 5V DC power adapter into the unit and
connect it to an AC wall outlet for power. (Optional, not required if
the unit is powered via PoE).
6.3 Remote Control
1PRESET 1~8 Buttons: This functionality is not currently
available and will be added in the “Phase 2”
update. 1

5
6.4 IR Cable Pinout
IR Extender
Cabl
e
1
2
3
Infr
ared
Power
Ground
6.5 RS-232 Pinout and Defaults
Serial Port Default Settings
Baud Rate 19200
Data Bits 8
Parity Bits None
Stop Bits 1
Flow Control None
1
2
3
RxD
GND
TxD
3-pin
Terminal Block
1
2
3
4
5RxD
TxD
GN
D
CTS
RTS
5-pin
Terminal Block
Unit Control Serial Output
Tabla de contenidos
Otros manuales de Controladores de CYP

CYP
CYP CDPS-IRL Manual de usuario

CYP
CYP DS-MSC14-4K Manual de usuario

CYP
CYP SDV-CS8 Manual de usuario

CYP
CYP CR-CS2 Manual de instalación

CYP
CYP IP-CS7 Manual de usuario

CYP
CYP IP-CS7 Manual de usuario

CYP
CYP CR-CS4 Manual de usuario

CYP
CYP DS-MSC Manual de usuario

CYP
CYP CDPS-IRL Manual de usuario

CYP
CYP DS-MSC14 Manual de usuario