CyberResearch IPDIO 7000 Series Manual de usuario

Digital I/O
Quick Start Guide
VER. 2.0C• Oct-09
No part of this manual may be reproduced without permission
IPDIO 7000 Series
6, 8,
12& 16 Channel Remote
EthernetDigital I/O Modules
®
CyberResearch®,Inc.
www.cyberresearch.com
25 Business Park Dr., Branford, CT 06405 USA
203-643-5000 (9 A.M. to 5 P.M. EST) FAX: 203-643-5001


CyberResearch® Digital I/O IPDIO 7000 Series
CyberResearch, Inc. iii
25 Business Park Drive P: (203) 643-5000; F: (203) 643-5001
Branford, CT USA www.cyberresearch.com
©Copyright 2009
All Rights Reserved.
October 19, 2009
The information in this document is subject to change without prior notice in order
to improve reliability, design, and function and does not represent a commitment
on the part of CyberResearch, Inc.
In no event will CyberResearch, Inc. be liable for direct, indirect, special,
incidental, or consequential damages arising out of the use of or inability to use
the product or documentation, even if advised of the possibility of such damages.
This document contains proprietary information protected by copyright. All rights
are reserved. No part of this manual may be reproduced by any mechanical,
electronic, or other means in any form without prior written permission of
CyberResearch, Inc.
Trademarks
“CyberResearch,” and “IPDIO 7000 Series,” are trademarks of CyberResearch,
Inc. Other product names mentioned herein are used for identification purposes
only and may be trademarks and/or registered trademarks of their respective
companies.
• NOTICE •
CyberResearch, Inc. does not authorize any CyberResearch product for use in life
support systems, medical equipment, and/or medical devices without the written
approval of the President of CyberResearch, Inc. Life support devices and
systems are devices or systems which are intended for surgical implantation into
the body, or to support or sustain life and whose failure to perform can be
reasonably expected to result in injury. Other medical equipment includes devices
used for monitoring, data acquisition, modification, or notification purposes in
relation to life support, life sustaining, or vital statistic recording. CyberResearch
products are not designed with the components required, are not subject to the
testing required, and are not submitted to the certification required to ensure a
level of reliability appropriate for the treatment and diagnosis of humans.

IPDIO 7000 Series CyberResearch® Digital I/O
iv ©Copyright 2009 CyberResearch, Inc.
Revision History
Revision # Description Date of Issue
1.01 Initial Release September 2009
2.0C Revision October 19, 2009

CyberResearch® Digital I/O IPDIO 7000 Series
CyberResearch, Inc. 1
25 Business Park Drive P: (203) 643-5000; F: (203) 643-5001
Branford, CT USA www.cyberresearch.com
IPDIO 7000 Quick Start Guide
Quick Start Guide for
IPDIO 7000 Series
Congratulations on purchasing IPDIO 7000 - the most popular automation
solution for remote monitoring and control applications, providing all the best
features of Web HMI and PLCs. This Quick Start Guide will provide
information needed to get started with IPDIO 7000. Please also consult the
User Manual for detailed information on the setup and use of IPDIO 7000.
In addition to this guide, the package includes the following items:
IPDIO 7000
Module Software Utility CD Screw Driver
Modules Covered
Module Description
IPDIO 7042 16-channel Sink Type Open Collector Isolated DO Module
IPDIO 7044 8-channel Sink Type Open Collector Isolated DO and
8-channel Isolated DI Module
IPDIO 7050 6-channel Sink Type Open Collector Isolated DO and
12-channel Isolated DI Module
IPDIO 7051 16-channel Isolated DI Module
IPDIO 7052 8-channel Source Type Open Collector Isolated DO and
8-channel Isolated DI Module
IPDIO 7053 16-channel Isolated DI Module
IPDIO 7060 6-channel Power Relay DO and 6-channel Isolated DI Module
IPDIO 7065 6-channel PhotoMos Relay DO and 6-channel Isolated DI Module
IPDIO 7066 8-channel PhotoMos Relay DO Module
IPDIO 7067 8-channel Power Relay DO Module

IPDIO 7000 Series CyberResearch® Digital I/O
2 ©Copyright 2009 CyberResearch, Inc.
1 ----------------------------------------------------------------------------------
Mounting the Hardware
The IPDIO 7000 can be mounted with the bottom of the chassis on the DIN
rail, the wall or piggyback. .
DIN Rail mounting
The IPDIO 7000 has simple rail clips for mounting reliably on
a standard 35 mm DIN rail.
Piggyback Mounting
The IPDIO 7000 has one hole on both sides for piggyback
mounting.
--------------------------------------------------------------------------
--------
Configuring Boot Mode
Make sure the switch placed in
the “Init” position.

CyberResearch® Digital I/O IPDIO 7000 Series
CyberResearch, Inc. 3
25 Business Park Drive P: (203) 643-5000; F: (203) 643-5001
Branford, CT USA www.cyberresearch.com
IPDIO 7000 Quick Start Guide
3 ----------------------------------------------------------------------------------
Connecting to Network, PC and Power
The IPDIO 7000 is equipped with an RJ-45 Ethernet port for connection to
an Ethernet hub/switch and PC
The IPDIO 7000 has
an input voltage
range of +10 ~ +30
VDC.
Connect the positive
terminal (+) of the power supply to the VS+ terminal J8 and the negative
terminal (-) of the power supply to the GND terminal J9.
4--------------------------------------------------------------------------
--------
Wiring Hardware
Connect the Analog/Digital devices to the IPDIO 7000.
Voltage Input Voltage Output
Current Input Current Output
Digital Input Digital Output

IPDIO 7000 Series CyberResearch® Digital I/O
4 ©Copyright 2009 CyberResearch, Inc.
5--------------------------------------------------------------------------------
--
Installing the MiniOS7 Utility
Step 1: Get the MiniOS7 Utility tool
The MiniSO7 Utility can be obtained from the software utility CD or
our website.
Step 2: Follow the prompts to complete the installation
After the installation has been completed, there
will be a new short-cut for MiniSO7 Utility on the
desktop.
6--------------------------------------------------------------------------
--------
Using MiniOS7 Utility to Assign a New IP
The IPDIO 7000 are web-based devices, which comes with a default IP
address, therefore, you must first assign a new IP address to the IPDIO
7000.
The factory default IP settings are as follows:

CyberResearch® Digital I/O IPDIO 7000 Series
CyberResearch, Inc. 5
25 Business Park Drive P: (203) 643-5000; F: (203) 643-5001
Branford, CT USA www.cyberresearch.com
IPDIO 7000 Quick Start Guide
Item Default
IPAddress 192.168.255.1
Subnet Mask 255.255.0.0
Gateway 192.168.0.1
Step 1: Run the MiniOS7 Utility
Double-click the MiniOS7 Utility
shortcut on your desktop.
Step 2: Press “F12” or choose “Search” from the “Connection”
menu
After pressing F12 or choosing Search from Connection menu, that will
search all of the MiniOS7
modules on your
network.
See the status tip, waiting
for the search to be done.

IPDIO 7000 Series CyberResearch® Digital I/O
6 ©Copyright 2009 CyberResearch, Inc.
Step 3: Choose the field “192.168.255.1” and then choose “IP
setting” from the toolbar
Choose default value “192.168.255.1” for fields in the list, and then choose
IP setting from the toolbar.
Step 4: Assign a new IP address and then choose “Set” button
You can manually assign an IP address or use DHCP to dynamically assign
IP addresses
Step 5: Choose “Yes” button
After completing the settings, the
Confirm dialog box will appear, and
then choose the Yes button to exit the
procedure.
Este manual sirve para los siguientes modelos
10
Tabla de contenidos
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario