CUE rfbaseCUE Manual de usuario

CUE, spol. s r.o. Na Dolinách 6 147 00 Praha 4 Czech Republic
phone: +420 241 433 555
fax: +420 241 432 446
www.cuesystem.com
User Manual
rfbaseCUE
Version 02

User Manual rfbaseCUE
UM011_02, 06.11.2002
Copyright © CUE, spol. s r.o. Praha, Czech Republic 1990 - 2002.
All rights reserved. Specifications are subject to change without prior notice.
Caution
Changes or modifications to this unit not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•Consult the dealer or an experienced radio/TV technician for help.

User Manual rfbaseCUE
www.cuesystem.com
Page 3 of 16
Table of Contents
1. Introduction....................................................................................................................................... 4
1.1. Overview.............................................................................................................................................. 4
1.2. Models ................................................................................................................................................. 4
1.3. Features .............................................................................................................................................. 4
2. Mounting the Base Unit ................................................................................................................... 5
3. Front and Rear Panels Description ................................................................................................ 6
3.1. CUEwire Connection ........................................................................................................................... 6
3.2. Host Computer Connection ................................................................................................................. 7
3.3. Indicators ............................................................................................................................................. 8
3.4. Antennas ............................................................................................................................................. 8
3.5. Fuse..................................................................................................................................................... 8
4. Service Mode .................................................................................................................................... 9
4.1. Overview.............................................................................................................................................. 9
4.2. How to Check Firmware Version ......................................................................................................... 9
4.3. Starting Service Mode ......................................................................................................................... 9
4.4. Upgrading the Firmware .....................................................................................................................10
4.5. Modifying Address of Wireless Control Panel.....................................................................................11
5. Troubleshooting ............................................................................................................................. 12
5.1. The POWER Indicator does not Light.................................................................................................12
5.2. The Short Operating Range................................................................................................................12
6. Specifications ................................................................................................................................. 13
7. Mechanical Drawings..................................................................................................................... 14

User Manual rfbaseCUE
www.cuesystem.com
Page 4 of 16
1. Introduction
1.1. Overview....................................................................
The rfbaseCUE is a unit that serves as an interface between wireless RF control panels and the
RS-485 bus.
Main functions
•Receives data from wireless RF control panels and transfers them via CUEwire (RS-485) to the
control units (Assistant or Assistant-S).
•Receives data from CUEwire (RS-485) and transfers them via RF to wireless RF control panels.
•Stores data when the wireless RF control panels are not active or out of range and transfers them
when the connection is newly established.
1.2. Models .......................................................................
Model Product code Description
rfbaseCUE CS0171-4 RF base unit, 433.92 MHz
rfbaseCUE CS0171-8 RF base unit, 869.85 MHz
rfbaseCUE CS0171-9 RF base unit, 914.5 MHz
1.3. Features.....................................................................
The main features of the base unit are
•PC host connector for service and programming
•CUEwire (RS-485) connection for communication with central unit of control system
•Two ¼ wave whip antennas
•Power supply 24 VDC (+/-20%), 2 W
•RF frequency 433.92 MHz or 869.85 MHz or 914.5 MHz
•RF power max. 10 mW (for 433.92 MHz) or max. 1 mW (for 869.85 MHz and 914.5 MHz)

User Manual rfbaseCUE
www.cuesystem.com
Page 5 of 16
2. Mounting the Base Unit
To fix the rfbaseCUE in a 19” rack use rack mount interface kit 19” fastened on to both sides of the
rfbaseCUE using screws.

User Manual rfbaseCUE
www.cuesystem.com
Page 6 of 16
3. Front and Rear Panels Description
3.1. CUEwire Connection ...................................................
The rfbaseCUE needs to be connected to CUEwire (RS-485 and power supply 24 VDC) in the same
way as other control panels.
Important note
There can be only one rfbaseCUE in one control system.
The rear panel is equipped with 4-pin type connector for CUEwire (RS-485 and power supply)
connection.
The unit is supplied via power input and the power requirements are 24 VDC (+/-20%), 2 W.
+ - A B
RS 485 rfbaseCUE
B-
A+
Ground
+ 24 VDC
1 432
The following table describes all CUEwire signals.
Code Pin nr. Meanin
g
Descri
p
tion Note
1 +24 VIN
2 Ground
Power input 24 VDC
3 In
p
ut/out
p
ut A+RS-485
4 In
p
ut/out
p
ut B-
RS-485 RS-485 connection

User Manual rfbaseCUE
www.cuesystem.com
Page 7 of 16
3.2. Host Computer Connection.........................................
The HOST connector on the front side serves for firmware upgrading and service functions. A
standard cable Sub-D, 9-pin, female to male, pin to pin is used for connection to a PC.
AI AO
HOST
POWER DATA
rfbaseCUE

User Manual rfbaseCUE
www.cuesystem.com
Page 8 of 16
3.3. Indicators ..................................................................
LED indicators are located on the front panel of the rfbaseCUE.
AI AO
HOST
POWER DATA
rfbaseCUE
DATA _________________________This indicator blinks when rfbaseCUE receives or sends valid
RF signals.
POWER _______________________When the POWER diode lights – it indicates the presence of
feeding voltage for an unit.
3.4. Antennas....................................................................
The integral antennas AO and AI are situated on the front panel of rfbaseCUE interface. The whip
antennas are ¼ wave, rotary, non-detachable.
The antennas are to be directed to open air and placed not close to metal pieces.
3.5. Fuse ...........................................................................
The unit is equipped with one resettable fuse rated 0.3 A. There are no serviceable parts inside the
metal case. If the unit is connected to the power, the POWER LED on the front panel lights on.

User Manual rfbaseCUE
www.cuesystem.com
Page 9 of 16
4. Service Mode
4.1. Overview....................................................................
The rfbaseCUE interface is provided with special service mode for servicing, testing and upgrading
firmware functions. To operate it, connect the rfbaseCUE to a PC and run proper communication
program - Windows Terminal or other similar general terminal program.
4.2. How to Check Firmware Version ................................
Before starting, please check first if you have all the following items
1. Windows PC with one free serial port.
2. Windows 95/98/NT/2000 with installed Terminal program or HyperTerminal in Windows
95/98/NT/2000.
3. Communication cable between rfbaseCUE HOST connector and PC.
Connect your PC to the rfbaseCUE HOST connector. Start the terminal program on your PC and then
set communication parameters to
Baud Rate....................................................19200
Data Bits ......................................................8
Stop Bits ......................................................1
Parity............................................................None
Flow Control ................................................Xon/Xoff
Connector ....................................................COM1 or COM2 (depending on which channel is used).
Switch off and on the power for the rfbaseCUE.
On your PC monitor you will see the type of version and the revision code. The message format is as
follows.
RfbaseCUE V0.01 7.3.00
4.3. Starting Service Mode ................................................
Before starting, please check first if you have all the following items
1. Windows PC with one free serial port.
2. Windows 95/98/NT/2000 with installed Terminal program or HyperTerminal in Windows
95/98/NT/2000.
3. Communication cable between rfbaseCUE HOST connector and PC.
Disconnect RS-485 signals A and B on the rear panel of rfbaseCUE.

User Manual rfbaseCUE
www.cuesystem.com
Page 10 of 16
There are two ways how to start the rfbaseCUE to operate in service mode.
1. Standard entry of service mode
Connect your PC to the rfbaseCUE HOST connector and run program SRVRFB.EXE. It switches
the rfbaseCUE into service mode.
2. Low level entry of service mode
If the rfbaseCUE does not respond to you or you do not have program SRVRFB.EXE, you must
remove upper cover of the rfbaseCUE. This way you get the access to buttons RESET an TEST
on the printed board. The TEST button is situated near receiving RF module while RESET button
is situated near microprocessor.
Then do the following
•Press both buttons on rfbaseCUE interface: RESET and TEST.
•Release RESET button still holding TEST for several more sec. (approx. 5 sec. is enough).
This will cause the rfbaseCUE to start in service mode.
When the unit is in service mode, the DATA LED indicator starts to blink regularly.
Start the terminal program on your PC and then set communication parameters to
Baud Rate....................................................19200
Data Bits ......................................................8
Stop Bits ......................................................1
Parity............................................................None
Flow Control ................................................Xon/Xoff
Connector ....................................................COM1 or COM2 (depending on which channel is used).
By pressing Nbutton in terminal program the following message appears.
CRAM not installed
rfbaseCUE V0.8 SERVICE mode: H,L,G,J,X,C,R,N,F,Z,P,S,M
>
Now the rfbaseCUE is waiting for commands from PC keyboard. Selecting H you will see a brief
description of each service mode commands on your monitor.
4.4. Upgrading the Firmware ............................................
Before starting, please check first if you have all the following items
1. File RFBxxx.ASX for the rfbaseCUE containing desired firmware version on your hard disc or
floppy disc. The latest firmware version is published regularly on the Cue’s web site www.cue.cz.
2. Windows PC with one free serial port.
3. Windows 95/98/NT/2000 with installed Terminal program or HyperTerminal in Windows
95/98/NT/2000.
4. Communication cable between rfbaseCUE HOST connector and PC.
Steps are
1. Enter the rfbaseCUE service mode as described above.
2. For upgrading the rfbaseCUE firmware select D.
Tabla de contenidos
Otros manuales de Unidad de control de CUE
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario