CryptOn CRT1081IRD-S2-MX Manual de usuario

CRT1081IRD-S2-MX
USER’s MANUAL
USER’S MANUAL
CRT1081IRD-S2-MX
Compact size 8-cha el multiplexi g DVB-S2 IRD
Crypton, January 2013

CRT1081IRD-S2-MX
USER’s MANUAL
1 GENERAL INFORMATION.......................................................................................................................................................4
1.1 DESCRIPTION
1.2 PACKAGING CONTENTS
1.3 TECHNICAL SPECIFICATIONS
2 SAFETY GUIDELINES................................................................................................................................................................7
2.1 GENERAL SAFETY GUIDELINES
2.2 DEVICE SAFE OPERATION GUIDELINES
3 INSTALLATION AND SETUP...................................................................................................................................................8
3.1 PHYSICAL DESCRIPTION
3.1.1 Front vie ........................................................................................................................................................................8
3.1.2 Rear vie .........................................................................................................................................................................8
3.2 HARDWARE INSTALLATION
3.3 HARDWARE SETUP
3.3.1 Default net ork settings................................................................................................................................................10
3.3.2 Net ork and authorization settings reset......................................................................................................................10
3.3.3 Reset the device configuration to the factory settings...................................................................................................10
4 CONFIGURING THE DEVICE USING WEB INTERFACE................................................................................................11
4.1 LOGING IN TO THE WEB INTERFACE
4.2 MAIN PAGE.
4.3 INPUT PAGE
4.3.1 Tuners setting up............................................................................................................................................................13
4.3.2 Common Interface setting up for CAM descrambling...................................................................................................14
4.3.3 ASI input state monitor..................................................................................................................................................15
4.4 ASI OUTPUT CONFIGURATION
4.5 DVB-OVER-IP CONFIGURATION
4.5.1 Device control IP configuration....................................................................................................................................16
4.5.2 DVB-over-IP streaming configuration..........................................................................................................................17
4.6 PROGRAM FILTERING
4.6.1 Input PSI/SI acuiring.....................................................................................................................................................19
4.6.2 Program service information previe ...........................................................................................................................20
4.6.3 Program assignment to multiplexes...............................................................................................................................22
4.6.4 PSI/SI edit......................................................................................................................................................................23
4.6.5 CRT1081IRD-S2-MX output configuration...................................................................................................................25
4.7 NIT & EIT INSERTION
4.7.1 EIT program scadule broadcast....................................................................................................................................27
4.7.2 NIT broadcast................................................................................................................................................................28
...........................................................................................................................................................................................................2
4.8 OPTIONS MENU
4.8.1 Net ork configuration...................................................................................................................................................29
4.8.2 Authentication................................................................................................................................................................30
4.8.3 Time and Data setiings..................................................................................................................................................31
4.8.4 Firm are update............................................................................................................................................................32
4.8.5 Fim are recovery..........................................................................................................................................................34
4.8.6 Import and export configuration information................................................................................................................35
Crypton, January 2013 2

CRT1081IRD-S2-MX
USER’s MANUAL
1 Gene al info mation
1.1 Descriptio
CRT1081IRD-S2-MX – is a compact size eight cha el DVB-S2 i tegrated receiver decoder with
embedded four cha el DVB remultiplexer. The device co sists of 8 full featured DVB-S/S2 receivers, 4
DVB-ASI i put i terfaces, flexibly co figurable 8-cha el Commo I terface for descrambli g services
a d 4-cha el DVB remultiplexer with DVB EPG processor, DVB-ASI a d DVB-over-IP outputs, all i
o e 19-i ch, 1U case. Such a compact a d high i tegrated solutio lets you build your etwork ce tral
statio with a exceptio al efficie cy. WEB co trol i terface lets you co trol all the system o matter
where you are at the mome t.
1.2 Packagi g co te ts
CRT1081IRD-S2-MX 1
AC power cord 1
User’s ma ual 1
Crypton, January 2013 3

CRT1081IRD-S2-MX
USER’s MANUAL
1.3 Tech ical specificatio s
DVB-S/S2 eceive s
Number of cha els 8
Receivi g freque cy ra ge 950-2150 MHz
I put sig al level -65…-25 dBm
Nomi al RF i put impeda ce 75 Ohm
Co ector type IEC, F-type
Max. LNB power 13/18 V, 400 mA
Symbol rate 1-45 Mbaud(QPSK, 8PSK)
FEC auto
Common Inte face
Number of cha els 8
Specificatio s EN50221, ETSI TS 101699
DVB-ASI inputs
Number of cha els 4
Specificatio s EN 50083-9
Co ector type IEC 169-8, BNC-type
Operatio modes auto detect
Max. i put bitrate, Mbit/s 213 (packet), 72 (byte)
DVB multiplexe s
Number of i put cha els 12
Number of output cha els 4
Specificatio s ISO IEC 13818-1
Max. output bitrate(all cha els O ) 300 Mbit/s(IP), 400 Mbit/s(ASI)
PID restampi g Yes
SI/PSI processi g Yes
DVB EPG server Yes(embedded)
DVB NIT server Yes(embedded)
PCR jitter < 500 s
DVB-ASI outputs
Number of output cha els 4
Specificatio s EN 50083-9
Co ector type IEC 169-8, BNC-type
Operatio modes Byte/Packet, 188 byte
Max. output bitrate, Mbit/s 213 (packet), 72 (byte)
DVB-over-IP
Specificatio ETSI TS 102034
Streami g protocol UDP
Streami g type Multicast/U icast
Number of DVB-over-IP streams 4 (ASI bou d MPTS)
Network i terface 1 Gbit Ether et
Cont ol softwa e HTTP server (Web)
Cont ol inte face 100 Mbit Ether et, TCP/IP
Supply voltage 100-240 V
Max. powe 60 W
Ope ational conditions
Crypton, January 2013 4

CRT1081IRD-S2-MX
USER’s MANUAL
Temperature 10…30 ºC
Relative Humidity Up to 95 %, without co de satio
Dimensions
Width, mm 440
Depth, mm 356
Height, mm 44
Crypton, January 2013 5

CRT1081IRD-S2-MX
USER’s MANUAL
2Safety guidelines
2.1 Ge eral safety guideli es
Use
the following guidelines
when unsafe
onditions
exist or when potentially hazardous
voltages are
present:
• Always use aution and ommon sense.
• To redu e the
risk of ele tri al sho k, do not
operate equipment with
the over
removed.
• Repairs must be performed by qualified servi e personnel only.
• Remember that voltages higher then 60 V DC or 30 V AC rms are dangerous.
2.2 Device Safe Operatio Guideli es
• Use only spe ified power supply and signals.
• Have devi e power off when doing onne tions.
• Proper able types must be used.
• Use the devi e under the spe ified environmental onditions.
• Do not obstru t the ventilation system.
Crypton, January 2013 6

CRT1081IRD-S2-MX
USER’s MANUAL
3 Installation and setup
3.1 Physical Descriptio
3.1.1 Fro t view
Fig. 1 Fro t view
1. Fro t pa el with mou ti g holes;
2. 1Gbit Ether et port for IP streami g of DVB services;
3. Device etwork/factory setti gs RESET butto ;
4. LEDs for tu ers lock a d CAM modules i sertio i dicatio ;
5. 100Mbit Ether et port for device co trol;
6. Commo I terface slots for CAM modules.
3.1.2 Rear view
Fig. 2 Rear view
1. 8 DVB-S/S2 receiver LNB i puts;
2. 8 DVB-S/S2 receiver Loop outputs;
3. 4 DVB-ASI outputs from multiplexers;
4. 4 DVB-ASI multiplexers i puts;
5. Power socket;
6. Power switch.
Crypton, January 2013 7

CRT1081IRD-S2-MX
USER’s MANUAL
3.2 Hardware I stallatio
The followi g seque ce of operatio s is recomme ded.
1. U pack the device a d check that all compo e ts are safe. If the device was take to the i stallatio
room from a colder place wait at least o e hour u til co de sed damp is dry.
2. Put the device at the place of operatio a d fix it properly. Special telecom rack is the best choice
for multiple devices i stallatio .
3. Provide ecessary co ectio s of LNB i puts, ASI i puts a d outputs.
4. Co ect the device Ether et port to the same type port of the host PC with cross cord or use patch
cord whe Ether et switch is used.
5.
Co ect the power supply cord
to a AC
outlet
. O ly specified voltage should be used. Pay a special
atte tio to use power cords a d plugs with a grou d wire.
The
chassis is grou ded through the three
pro g AC receptacle.
6. I sert CAM Modules i to Commo I terface slots. To preve t damage of the i terface o ly use
EN50221 specified CAM Modules, push them ge tly o exceedi g effort is required.
7. Switch the device power o . Short period LED lights sig al the device is ready to operate.
Crypton, January 2013 8

CRT1081IRD-S2-MX
USER’s MANUAL
3.3 Hardware setup
3.3.1 Default etwork setti gs
The followi g default etwork setti gs are usually appear whe fist time device power o . Please
check that your Host PC etwork setti gs match to those default setti gs to make the the device
co ectio .
MAC address 00:01:00:15:xx:xx
IP address 192.168.0.100
Sub et Mask 255.255.255.0
Gateway IP address 0.0.0.0
Logi admi
Password admi
Note. Please see your device MAC address i formatio attached to the accompa yi g
docume tatio .
3.3.2 Network a d authorizatio setti gs reset
You ca reset the device etwork setti g a d access rights to the default a y time you
eed. Whe the device is operati g please carefully press IP RESET butto o the fro t pa el a d hold for
1-2 seco ds. The device will automatically start reboot for ew setti gs to take effect. Use the default
etwork a d authorizatui setti gs to access the device.
3.3.3 Reset the device co figuratio to the factory setti gs
You ca reset the device co figuratio to the factory setti gs. Whe the device is operati g please
carefully press IP RESET butto o the fro t pa el a d hold at least 20 seco ds a til LEDs start bli ki g.
The device will automatically start reboot for ew setti gs to take effect. Factory co figuratio appears
after reboot.
Crypton, January 2013 9

CRT1081IRD-S2-MX
USER’s MANUAL
4 Configu ing the device using WEB inte face
4.1 Logi g i to the WEB i terface
Before you start please he k the following.
•
An
IP address that
identifies the CRT1081IRD-S2-MX Ethernet interfa e
on
the
LAN, and the
Subnet Mask for the
LAN
segment.
•
A 10BaseT or 100BaseT network onne tion.
•
A grounded AC
power outlet.
•
A PC
or other workstation with
a web
browser
onne ted to the
network to a ess the
Web
Interfa e to onfigure
the unit for operation. It is re ommended to use
the following list
of urrent or later Browser versions:
Google Chrome 3.0
Firefox 3.5
Opera 10
Internet Explorer 8.0
Note. 192.168.0.100 – is the default IP address
Enter urrent Login and Password to a ess the devi e settings.
Fig. 3 Authorization page
Note. Default password is admin.
Note. See 4.8.4 for authorization rights hange.
Note. After 15 minutes of ina tivity the devi e will dis onne t automati ally.
Crypton, January 2013 10
Tabla de contenidos