General Descripon
Thank you for purchasing the PAP Clean Portable CPAP Cleaning System
The enre portable, care-free and dry process requires no water, soap
or detergents to clean. You can clean and deodorize all your CPAP
related accessories including your mask, tubing and water humidier
chamber through a stream of controlled ozone.
• Do not stand over ozone generator while it is operang.
• Do not ingest or breathe in the ozone release. Always use in a well
venlated area.
• Do not aempt to deodorize your CPAP in the cleaning bag.
• Do not reassemble your CPAP accessories for at least one hour
aer cleaning, or anyme the ozone generator has stopped.
The screen will display and when the cycle is nished.
• If you experience shortness of breath or respiratory issues, consult
your physician immediately.
• Keep out of reach of children.
• Do not let children play with the product.
• Use only as intended to clean CPAP accessories. The ozone concen-
traon is regulated by the ozone device, bag and the run me. Use
only as directed.
Environmental Noce
This product contains a rechargeable baery. To support a greener
environment, please do not dispose of this product with household
waste. Please follow appropriate local regulaons regarding the
disposal of baeries in your area.
2
WARNING

Ozone Generator
The PAP Clean Portable CPAP Cleaner includes a rechargeable
baery. To charge it, connect the device as shown below. Connect
the USB cable to the charging block and plug into a power outlet.
A charging symbol will come on when it is charging correctly.
The full baery icon will display when it is fully charged.
The white poron in the baery icon shows the remaining power
capacity of the baery. When the baery has less than 5% baery life this
empty baery icon is displayed and the unit starts to ush.
For the best baery performance and baery life, power o while
charging. Charging me averages 2-3 hours and may vary depending
on the baery’s remaining capacity. If the unit stops working during
use aer a full charge, the baery may have reached the end of its
service life and the enre unit will need to be replaced.
3
Tubing Port
Charging the Baery
Status Screen
Type C-Inlet Air Inlet
On/O Buon
Mode Buon

Before you begin...
1) Do not aempt to clean CPAP device, only
Humidier Tub, Tubing and CPAP Mask
WARNING: Never breathe in or ingest ozone
2) Disconnect CPAP Tubing from PAP Therapy Device
3) Remove Humidier
Chamber/Tub from
PAP Device.
Separate Tubing & Humidier Chamber/Tub
4

Empty Humidier Chamber/Tub
4) Thoroughly remove all water from
the Humidier Chamber/Tub.
5) Hold the Cleaning Bag as shown, with open zipper on the le
and the Velcro strap on the right. Place the empty Humidier
Chamber/Tub in Cleaning Bag, towards the le side.
5

Place PAP Mask & Tube in Cleaning Bag
6) Place CPAP Mask and connected tube inside the bag.
You only need a few inches of CPAP Tube inside the bag.
7) Zip the bag closed from le to right.
6

Wrap Tubing in Cleaning Bag
8) Make sure the zipper “pull tab” is lied upward against the
tube. Then pull the Velcro strap downward behind the tube.
9) Once the strap is wrapped around the tube, pull it
back towards the closed zipper “pull tab” and secure
it in place.
7

Connect Tube to the Ozone Generator
10) Connect tube adapter onto the Ozone Generator
11) Connect CPAP Tube to Ozone Generator
12) Lay the bag on a at surface,
in a well venlated area
with the Ozone Generator
connected in the following
manner:
8

Turning on the Ozone Cleaner
On/O Buon
Do not aempt to clean CPAP Device in cleaning bag.
Once you have placed the PAP accessories in the cleaning bag,
properly zip the bag closed, secure the CPAP tube in place and con-
nect the tube to the ozone generator, then turn the device “On”.
Press and hold the On/O buon for 5 seconds. You will hear a
long “beep” and the unit will start streaming ozone. The unit has
two modes: Standard “STD” (default mode) and Quick “QIK”.
“STD” MODE: “QIK” MODE:
30 Min Cleaning 25 Min Cleaning
5 Min Air Flush 10 Min Air Flush
60 Min Reverng 30 Min Reverng
When completed When completed
Hold the Mode Buon for 3 seconds to shi between STD and QIK.
The unit will beep when shiing modes.
At any me, hold the on/o buon for 3 seconds to shut it o.
9
Mode Buon

Heated Tubing & Travel Tubing
If you have a CPAP with a heated tube or a Travel CPAP using a
specialized tube, simply use the included short CPAP tube as a
conduit between the ozone generator and the cleaning bag.
1) Place CPAP Mask and enre specialized tube inside the bag.
2) Place the short tube parally in the bag, zip the bag closed,
wrap the Velcro around the tube.
10
3) Connect the short tube to the ozone generator and turn it on.