Continal 39003-tsrf Manual de usuario

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
Quantum digital
thermostat-RF
The Quantum digital thermostat-RF is stylish, modern, wireless and packed full of app-
controlled features. Recharging is simple via the micro USB port.
Easy to set up and control, this self-learning thermostat can be operated remotely via your
smart device or manually through its intuitive interface.
Contents
1. Before you start
2. LCD icon description
3. Button description
4. Compatibility with other Continal devices
5. First power-up sequence
6. Linking
7. Full menu structure
8. Operating in oine mode
9. Short description of admin settings
10. Error codes
11. Product compliance and safety

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
1. Before you start
Symbols explanation:
S – Volt-free contact
T – Temperature sensor
S1, S2 Terminals:
- Air or oor temperature sensor
- External volt-free contact to connect any
ON/OFF switch or occupancy sensor
S1
S2
T
S
Wall mounting
The ideal position to mount the thermostat is 1.5m above oor level and away from heat sources.
The Quantum digital thermostat-RF should not be exposed to sunlight or any extreme conditions
(including draughts).
123
Mounting: To wall mount the thermostat, use the accessories supplied. (1) The wall plate can be
mounted by using either the supplied (2) self-adhesive mounting tape or (3) the mounting screws.
Once in place, just attach the thermostat (both thermostat and plate have built-in-magnets).
Wiring diagram

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
2. LCD icon description
1. Menu / Settings description + clock
2. AM / PM
3. Temperature unit
4. Heating indicator (animated when demand)
5. Cooling indicator (animated when demand)
6. RF connection indicator
7. Internet connection indicator
8. Occupancy sensor
9. Key lock function
10. Standby mode icon
2
8
9
10111214
15
20
19
18
17
16
1
3
4
5
6
7
13
11. Current temperature / setpoint temperature
12. Holiday mode
13. Temporary override mode
14. Settings icon
15. Status indicator
16. External / oor temperature sensor indicator
17. Schedule programme number
18. Schedule mode icon
19. Day indicator / SET information
20. Current humidity value

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
3. Button description
4. Compatibility with other Continal devices:
Button Function
1) Menu button / return button.
2) In the main screen: press and hold for 3 seconds to change the thermostat
operating mode (schedule mode / permanent mode / temporary override mode).
3) In the settings screen: press and hold for 3 seconds to go back without saving the
changes.
4) In the pairing screen (in system type menu): press and hold for 3 seconds to see
other pairing options.
“Down” button (decrease value / move the menu in the ‘down’ direction).
“Up” button (increase value / move the menu in the ‘up’ direction).
1) Press and hold for 3 seconds to power up.
2) “Ok / tick” button (conrm parameter value / go to the next menu / save settings).
3) Main screen: press and hold for 3 seconds to enter standby mode.
4) Settings screen: press and hold for 3 seconds to go back to the main screen & save all
your changes.
5) During pairing process – hold button for 3 seconds to power o or reboot the
thermostat.
+
In the main screen - press and hold these buttons together for 3 seconds to lock /
unlock the thermostat keypad).
The Quantum digital thermostat-RF can work in online or oine mode.
*Mode selection is available on rst use.
Download the Salus Smart Home app on your iOS or Android device.
Salus Smart
Home app
Online mode
Offline mode
Quantum hub connected.
You can congure and use all
your devices in the Salus Smart
Home app.
Quantum hub not connected.
You can use your devices locally.
This works using the ZigBee
network.

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
5. First power-up sequence
6. Linking
Please note: For easy installation, please make sure you have already added your other devices to
the ZigBee network, such as wiring centres etc.
To power on, hold
the button for 3
seconds. The display
will show all icons.
The thermostat will
display the software
version.
Now, choose your
language by using the
or buttons. Conrm
your language using the
button.
123
Refer to the Quantum digital thermostat-RF linking quick guide for instructions on how to link the
Quantum digital thermostat-RF. This can be found at www.continal.eu/quantum
7. Full menu structure
Admin settings:
• Temperature scale
• Display temperature resolution
• Heat control algorithm
• Cool control algorithm
• S1 / S2 input
• Minimum setpoint
• Maximum setpoint
• Valve protection
• Minimum turn-o time
• Optimisation feature
• Comfort warm oor
• Pin code
• Device information
• Factory reset
Schedule settings:
• Disable
• MO-FR+SA-SU
• MO-SU
• Single days
User settings:
• Time / date
• Holiday mode
• Thermostat calibration
• Show / hide display humidity
• Show / hide display floor
• Standby temperature setpoint
• Heat / cool
• Reset user settings

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
8. Operating in oine mode
Conrm by pressing
the button.
Use the or
buttons to set the
temperature.
123
Setting temperature change (manual mode)
The thermostat will
go back to the main
screen.
Setting time / date
Setting the time / date manually can only be done in oine mode. In online mode the Quantum
digital thermostat-RF will automatically synchronise the current time and date.
Go to the user
settings.
Press the button to
enter the main menu.
123
Select the time / date
option.
Use the or
buttons to set the
time.
Select the clock
settings.
45
Use the or
buttons to set the
date.
6

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
Enter the schedule
settings.
12
3
Programming mode
Separate schedules
for weekdays and
weekends.
There are 3 possible schedules to choose from.
456
The next programme
will appear, this will
be the lower comfort
temperature. Repeat
steps 4 and 5 for the
next schedules required.
There can be 3 time
periods set within the
schedule. To skip set
periods use --:--. Once
the nal schedule has
been added hold for 3
seconds to save and exit.
Press the button to
enter the main menu.
Seven separate
schedules for single
days.
One schedule for the
whole week.
Programming example shown is for the whole week.
Use the or
buttons to set the
time. Press the
button to conrm.
Use the or
buttons to set
the temperature
setpoint. Press the
button to conrm.
After setting the program, the calendar icon will show on the display.

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
4
Holiday mode
Select yes to activate
holiday mode.
Holiday mode will maintain a temperature setpoint for a specic amount of time.
8
Press any button
while in holiday
mode.
To disable holiday
mode, select yes and
press the button
to conrm.
Go to the user
settings.
Press the button to
enter the main menu.
123
Choose the holiday
mode option.
Use the or
buttons to set the
duration (in days).
Press the button
to conrm.
Use the or
buttons to set
the temperature
setpoint. Press the
button to conrm.
7
When holiday mode
is active, this is
shown by the plane.
The thermostat will
show how long is
left on the top of the
display.
To turn o holiday
mode.
45 56

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
3
Display humidity
Select the display
humidity option.
The Quantum digital thermostat-RF has a built-in hygrometer (humidity sensor).
The humidity value can be displayed or hidden.
Go to the user
settings.
Press the button to
enter the main menu.
12
Use the or
buttons to show or
hide the humidity
indication. Press the
button to conrm.
44

Rev:03/21
© 2021 Continal Group Ltd. All rights reserved. E & OE.
UNDERFLOOR HEATING
4
Display oor temperature
The oor
temperature is
displayed with one
degree of accuracy.
Display oor temperature is a function available when using the Quantum oor sensor.
Go to the user
settings.
Press the button to
enter the main menu.
123
Choose the display
oor temperature
option.
Use the or
buttons to show
or hide the oor
temperature. Press
the button to
conrm.
45
Otros manuales para 39003-tsrf
1
Tabla de contenidos
Otros manuales de Termostato de Continal
Manuales populares de Termostato de otras marcas

EWELLY
EWELLY EW-181 Manual de usuario

Prolon
Prolon T1100 Instrucciones de instalación

Computherm
Computherm Q20 Manual de usuario

Heatmiser
Heatmiser neoStat Manual de usuario

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Manual de usuario

Mars
Mars HEAT CONTROLLER IR Wireless Thermostat Manual de usuario