Conlan CT2000 Manual de usuario

secure open
Conlan ApS • Speditorvej 2A • DK-9000 Aalborg • Tel: +45 72 40 60 03 • Fax: +45 96 32 00 22
www.conlan.eu • [email protected]
Keypad
CT2000
Art. No.: 460001, 460005 (black)
Art. No.: 460007, 460014 (white)
Installation Manual
CT2000_installation_ENGmay15

2
Table of contents
1. Introduction
2. Programming
2.1 Minimum programming
2.2 Master Code (100)
2.3 Service Code (101)
2.4 ID number (102)
2.5 Output choice (103)
2.6 Blocking time (104)
2.7 LED’s (105)
2.8 Output time for codes (110 - 122)
2.9 Reset
2.10 Positions
2.10.1 Programming positions
2.10.2 Changing positions
2.10.3 Delete positions
3. Mechanical mounting
4. Electrical connection
5. RS485 communication
5.1 Shielded cable
5.2 Wired method
6. Technicalspecications
7. Installation of PC Interface
7.1 PCI2000
7.2 LogBox 3
page 3
page 5
page 5
page 7
page 7
page 7
page 8
page 10
page 11
page 12
page 12
page 13
page 13
page 14
page 15
page 16
page 17
page 21
page 21
page 22
page 24
page 25
page 25
page 25

3
1. Introduction
CT2000 is a advanced keypad manufactured in Denmark. It can be used as stand
alone keypad and as a part of a larger system. The keypad has the following features:
•Easytouse.
•Waterproof.
•Nomechanicalswitches-durable.
•Precautionsagainstcodeguessing:
•Thekeypadblocksafter4invalidcodesforaperiodofupto255seonds.
•100dierentusercodes.
•1MasterCodeand1ServiceCode.
•Allcodescanbeprogrammedwith1to8digits.
•ProgrammableLED’s.
•Severaloutputpossibilities(advancedRS485communication).
•Outoutcanbeprogrammedastimeroron/o(toggle).
•Possibilityofconnectionforlogprinting.
•Standalone,noaccessoriesneeded.
Typical applications:
•Asasimpleaccesscontrolsystemmonitoringtheelectriclockofasingledoor.
•Asaremotekeypadinaintrusionalarmsystem.
•Asanaccesscontrolsystem.
•Asatimeregistrationequipment.
•Toturnsafetyequipmentonando.
•AsaremotesystemmanagedoverWAN/LAN.
•CanbeprogrammedasstandaloneandbythesoftwareConlaneXPress(see
page 26 - 27).
•OptionallytheLED(redandgreen)canbeactivatedbyextrawires(seepage
14) Art. No.: 460070 and 460071.

4
2. Programming
Programming of the keypad is done by changing the value of one or more of the 118
dierentpositions.Eachofthepositionsnumbered00to102cancontainacodecon-
sisting of 1 to 8 digits. The rest of the positions controls how the keypad works.
Notice:Thekeypadisdierentfromotherkeypadsonthemarket.
It has no mechanical keys, but is operated just by touching the keys.
Pay special attention to the yellow LED.TheLEDashesevery
time the keypad has registered that you have touched a key.
To programme the keypad, please do as follows:
1. Connect the supply voltage to the keypad. After the connection you have
one chance to key in the Service Code followed by a touch on the < # >
key.
2. Key in the Service Code < 12347890 > followed by a touch on the < # > key
(notice that the Service Code does not contain the digits 5and 6).
3. If you key in the wrong Service Code, you have to start over again from 1.
Pay special attention to the LED’s after each touch.
•Green LED on, indicates that the keypad is in programming mode.
•Yellow and green LED on at the same time, indicates that there has been
keyed in a position number followed by a touch on the < # > key.
•YellowLEDonalone,indicatesthatthekeypadharrecievedthevalueforthe
rsttime,andthatithasbeenfollowedbyatouchonthe< # > key.
•Afterthevaluehasbeenconrmedbyanothertypingofthesamecode,fol-
lowed by a touch on the < # >key,theyellowLEDwillbeo,andthegreen
LED will be on again.
•Toleavetheprogrammingmode,pushthe< # > key again. Now the yellow
LED will indicate normal operation (default programming).

5
2.1 Minimum programming
CT2000canbeprogrammedforavarietyofdierentthings.Ifyousimplymusthave
the keypad to function with factory programming - its the programming options that
suits most applications - do as follows:
Changing Service Code
The Service Code, which is factory set to 12347890 should be changed so that unau-
thorized persons can not gain access to change the keypads setup. The Service Code is
on position 101- see page 13 Programming positions to change the Service Code.
Program Master Code
Thisisonlyrequirediftheusershouldbeabletoprogram,changeordeletecodes.
The Master Code has no value at the factory, but must be in position 100 - see page
13 Programming positions to program the Master Code.
Switching output function and/or time
CT2000’s open collector output is factory set to provide a 0V DC from it on the po-
sitions 110 - 122 programmed time (e.g. in 5 seconds). The open collector outputs
functions is programmed in position 103 and is factory set to the value 1, which cor-
responds to the above 0V DC whenever you enter the correct code on the keypad.
Change this value to 2 reversed the the open collector output, providing 12/24V DC
when properly entered code.
Switching LED settings
CT2000’s LED settings change on position 105. See table on page 11 for choice of set-
ting. See page 13 Programming positions to program the position.
Performes the minimum programming above, Can the CT2000 keypad immedially be
used.

6
Positions:
Position: Controls:
00 - 99 User codes (1 - 8 digits)
100 Master Code (1 - 8 digits)
101 Service Code (1 - 8 digits (factory default 12347890))
102 ID number
103 Output selection (slave, timer function, reversed timer function).
104 Blocking time in case of code guessing (0 - 255 seconds)
105 LED’s functions and indications.
106 Master programming level.
110 Output time for user code 00 - 07
111 Output time for user code 08 - 15
112 Output time for user code 16 - 23
113 Output time for user code 24 - 31
114 Output time for user code 32 - 39
115 Output time for user code 40 - 47
116 Output time for user code 48 - 55
117 Output time for user code 56 - 63
118 Output time for user code 64 - 71
119 Output time for user code 72 - 79
120 Output time for user code 80 - 87
121 Output time for user code 88 - 95
122 Output time for user code 96 - 99
Default programming = factory set:
Position Code Group
00 1234 0
101 12347890
Position Value Means:
102 1 ID number 1
103 1 Stand alone and timer function on transistor output.
104 5 5 seconds.
105 0 YellowLEDonstandbyandgreenLEDonwhenkey-
pad is activated.
106 100 Master can change user codes on positions 00 to 99.
110 - 122 5 Open collector output activated in 5 seconds
All other positions are “empty” when the keypad leaves the factory.

7
2.2 Master Code (100)
The Master Code is a limited version of the Service Code. It is only authorized to
change the values on positions 00 - 99. That means change user codes. The code can
be used by the person that is taking care of the daily operation of the system.
The Master Code has position 100, but it is empty when the keypad leaves the factory.
The Master Code can only program, change or delete user codes. It can not acti-
vate the open collector output.
2.3 Service Code (101)
The Service Code is used to put the keypad into programming mode. The code gives
access to change user codes and Master Code and to change the function on the key-
pad.
The Service Code has position 101, and the values is, when the keypad leaves the fac-
tory set to 12347890 (notice that the Service Code does not contain the digits 5 and 6).
The Service Code can only change the function of the keypad, but can not acti-
vate the open collector output.
This code is only valid immediatly after, the supply voltage has been connected!
This is done to optain a maximum safety against sabotage to the keypad.
2.4 ID number (102)
This position can contain a value between 1 and 255. The value indicates which ID
numberthekeypadhas(ifitisapartofalargersystem).Youhavetheopportunityto
control up to 255 keypads on the same data-bus.
The value on position number 102 is 1 when the keypad leaves the factory (ID number
1).

8
2.5 Output choice (103)
The value on this position decides how the keypad reacts when typing a user code.
Value: Function:
0 (Not used)
1 Output active timer time
2 Inverted output
3 (Not used)
4 Rolling code, 4 digits
5 Rolling kode, 4 digits, inverted output
6 Rolling code, 6 digits
7 Rolling code, 6 digits, inverted output
8 (Not used)
9 Ask for output status
Function 0 Not used.
Function 1 Output active in timer time.
Function 1 activates the keypad open collector output with a 0 VDC
in accordance with the programmed time (position 110 -
122, for example for 5 seconds).
Function 2 Inverted output.
Function 2, removes 0 VDC from the keypads open collector
output in accordance with the programmed time (position 110 -
122 in for example 5 seconds).
Funktion 3 Not used.
0
0V
V
Approved code Approved code
Timer function (1, 4, 6) Inverted timer function (2, 5, 7)

9
Function 4 Rolling code, 4 digits.
Function 4, select a option where the keypad accepts a 4 digit
codewithoutsubsequentuseofthe< # >. The code is ap-
proved, so even though it is in the middle in a longer entry se-
quence.Isthecorrectcodeexamplein1234andenteredthe
347123487, approves the code.
Is the correct code not entered within 16 entries, will the
keypad automatically reset after 10 seconds - indicated by a
ashfromtheredLED.Bythe16thentrywillthekeypad
beblockedforattimeequaltothecurfewintheposition104.
Upon entering the 4 digit code with pending reset (10 seconds)
the keypad will block after entering 4 wrong 4-digit codes.
To get in the master programming must ther be entered 4
timesonthe<#>key.Therst3times,theredLEDashing.
Bythe4thentrywilltheLEDstopashing,indicatingthat
the Master Code is ready for input. After the 5th key of < # > is
it no longer possible to record the Master Code.
If the Master Code is not entered within 65 seconds turns func-
tion 4. Completes the Master Code not with < # > turns function
4 after 10 seconds. Then can the keypad again be set to master
programming, as described above.
Function 5 Rolling code, 4 digits, inverted output.
Like function 4, but with inverted output.
Function 6 Rolling code, 6 digits.
Function 6, select a option where the keypad accepts a 6-digits
code without using < # >. There is still blocking after code
guessing. The keypad is locked after 24 incorrect entries (digits).
The blockade may be previousle set from 1 second to 9 min-
utes. See description under function 4.
Function 7 Rolling code, 6 digits, inverted output.
Like function 6, but with inverted output.
Function 8 Not used.

10
Function 9 Ask for output status.
Function 9 will by entering a code followed by < # > show sta-
tus at the output of a number of seconds, after which indication
isturnedo.Thenumberofsecondscanbesetfrom1-30
from position 122. During the status display, it is possible to
change the status by typing the < %> key. The change of status
is indicated by green respectively red LED in 9 seconds (green =
active, red = inactive). Status can only change once per. code
approved. The factory setting is 1.
2.6 Blocking time (105)
If someone is trying to guess a code, the keypad wil, after 4 invalid codes, be
blockedforaperiodoftime.DuringthisperiodoftmietheredLEDwillashto
indicate that the keypad is blocked and no typing is possible. The value of this
position decides how long the keypad will be blocked if someone tries to guess
a code.
The value is 5 (5 seconds) when the keypad leaves the factory.
Otros manuales para CT2000
1
Tabla de contenidos
Otros manuales de Teclado de Conlan

Conlan
Conlan CT2000 Manual de usuario

Conlan
Conlan CT 1000 Manual de usuario

Conlan
Conlan CT1000 Manual de usuario

Conlan
Conlan CM1000 Manual de usuario

Conlan
Conlan Mykey CP1000 Manual de usuario

Conlan
Conlan CB 1200 Manual de usuario

Conlan
Conlan C1000LP Manual de usuario

Conlan
Conlan CB1200 490030 Manual de usuario

Conlan
Conlan C1000 Manual de usuario