VS30W/VS30B THERMOSTAT - FULL USER MANUAL


TABLE OF CONTENTS
1. Introduction...............................................................................................................................................................4
1.1 Product Compliance ......................................................................................................................................................................4
1.2 Safety Informations.......................................................................................................................................................................4
1.3 Product Overview..........................................................................................................................................................................5
2. Montage ....................................................................................................................................................................6
2.1 Package content............................................................................................................................................................................6
2.2 Proper thermostat location ...........................................................................................................................................................6
2.3 Connection description..................................................................................................................................................................7
I A - 4 wire installation with KL08NSB wiring centre.............................................................................................................8
I B - 4 wire installation with KL06 wiring centre.................................................................................................................10
II - 3 wire installation with KL08NSB wiring centre ............................................................................................................12
III A - work with RM-16A relay module - volt-free heating source control..........................................................................14
III B - work with RM-16A relay module - connection to a solid fuel boiler controller..........................................................14
III C - work with RM-16A relay module - connecting an electrical device with a higher power ..........................................15
3. Before you start (rst power up) ................................................................................................................................16
3.1 LCD icon description ....................................................................................................................................................................16
3.2 Button description.......................................................................................................................................................................16
3.3 First power up sequence..............................................................................................................................................................17
4. Work modes..............................................................................................................................................................18
5. User settings (basic settings) .....................................................................................................................................19
5.1 Schedule mode - programming schedule....................................................................................................................................19
5.2 Time/Date ...................................................................................................................................................................................22
5.3 Thermostat calibration ................................................................................................................................................................23
5.4 Heat/cool mode change ..............................................................................................................................................................24
6. Installer parameters .................................................................................................................................................25
7. Factory Reset............................................................................................................................................................27
8. Error codes ...............................................................................................................................................................28
9. Cleaning and Maintenance ........................................................................................................................................28
10. Technical Informations............................................................................................................................................28
11. Warranty................................................................................................................................................................29

4
This product complies with the essential requirements and other relevant provisions of Directives 2014/53/EU and 2011/65/EU. The full text of the EU
Declaration of Conformity is available at the following internet address: www.saluslegal.com.
• Before starting installation work and before using the product, read the entire manual.
• The information contained in the instructions is essential for proper functioning.
• To avoid accidents resulting in personal injury and material damage, please follow all safety precautions, specied in this manual.
• The device should not be used by people with limited mental, sensory or mental abilities, without experience, of insucient knowledge as well as
children.
• Do not use an unassembled device (eg without a cover).
• The device may only be opened by a qualied person.
• Keep electrical devices out of the reach of children and ensure that they do not play with it. Children should not be left unattended. If necessary,
disconnect the control system for the entire room.
• Do not leave the packaging, cabinet, or any loose parts of the device unattended, as they pose a risk to children.
WARNING!
• Installation must be carried out by a qualied person with appropriate electrical qualications in accordance with standards and regulations in force in
the given country and in the EU.
• Never try to connect the device other than as described in the manual.
• Before assembly, repair or maintenance as well as during any connection works it is absolutely necessary disconnect the mains supply and make sure
that the terminals and electric wires are not live.
• The device may not be exposed to extreme temperatures, strong vibrations or subjected to mechanical shock.
• The device should not be used in unfavorable environmental conditions or in rooms where there is a concentration of ammable gases, fumes or dust.
WARNING!
• There may be additional protection requirements for the entire installation that the installer is responsible for maintaining.
1. Introduction
1.1 Product Compliance
1.2 Safety Informations
Care for the natural environment is of paramount importance to us.The awareness that we manufacture electronic devices obliges us
to dispose of used electronic components and devices safely. Therefore the company has received a registration number issued by the
Chief Inspector for Environmental Protection.The crossed out symbol the trash can on the product means that the product must not be
disposed of with ordinary waste containers. Sorting waste for recycling helps to protect the environment. It is the user’s responsibility
to surrender used equipment to a designated collection point for recycling waste from electrical and electronic equipment.

5
TheVS30W/VS30B from SALUS Controls is a stylish and accurate 5/2 or 24h programmable electronic thermostat with a large, easy to read Liquid Crystal
Display (LCD). It is ush-mounted temperature controller dedicated for surface heating / cooling, characterized by high thermal inertia. It is connected
to the wired wiring centre KL08NSB. Thermostat has the function of creating your own schedules. It can control group (SLAVE) thermostats - via wiring
centre it sends them an NSB (nighttime temperature reduction) signal and switches them to economic temperature. The time schedule is common to all
thermostats (according to weekly (MASTER) thermostat), but temperatures are set individually on each thermostat.
The programmable room thermostat VS30W/VS30B is both a programmer and a room thermostat. A programmer allows you to set ‘ON’and ‘OFF’time
periods to suit your own lifestyle. A room thermostat works by sensing the air temperature, switching on the heating when the air temperature falls below
the thermostat setting and switching it o once this set temperature has been reached.
So, a programmable room thermostat lets you choose what times you want the heating to be on, and what temperature it should reach while it is on.
It will allow you to select dierent temperatures in your home at dierent times of the day (and days of the week) to meet your particular needs.
Turning a programmable room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the
design of the heating system, for example, the size of boiler. Neither does the setting aect how quickly the room cools down. Turning a programmable
room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy.
The way to set and use your programmable room thermostat is to nd the lowest temperature settings that you are comfortable with at the dierent
times you have chosen, and then leave it alone to do its job.The best way to do this is to set low temperatures rst, say 18°C, and then turn them up by one
degree each day until you are comfortable with the temperatures.You won’t have to adjust the thermostat further. Any adjustments above these settings
will waste energy and cost you more money.
PRODUCT ADVANTAGES:
• has a PWM control algorithm
• protection against too high or too low temperature using an additional FS300 oor sensor
• valve protection function
• an input for the additional temperature sensor
• has frost protection mode
• working with actuators of both types - NC and NO
• mounting in a φ 60 mm wall box
1.3 Product Overview

6
2. Montage
2.1 Package content
1) VS30W/VS30B thermostat
2) Short instruction
3) Mounting screws
2.2 Proper thermostat location
Please note:
Wall mounting
Mounting: to mount thermostat you can use accesories included with the set (mounting screws). Remove back cover to mount the plate to the wall.
After this just attach thermostat to the plate right into designed holes in the plate. The VS30 thermostat has been designed for ush mounting in a
standard electrical box with a diameter of 60 mm.
The ideal position to thermostat mounting is about 1,5m under oor level far from heating or cooling sources.
Thermostat can’t be exposed to sunlight or any extreme conditions like for example draft.
Because of re and explosion risk there is not allowed to use thermostat in atmosphere of explosive gases and ammable liquids (eg coal dust). In case
if any of listed dangers occur you have to use additional protection measures – anti-dust and explosive gases (tight cover) or prevent their formation.
Furthermore, thermostat can’t be used in condensation of water vapor conditions and be exposed to water action.
12
3
Open the housing with a
screwdriver - as shown in
the pictures above.
Mount the plate to the
wall using mounting
screws, in the correct
direction.
After all, attach the thermostat
to the plate. Use the plastic
hinges and make sure that wires
are in the correct place with the
thermostat.
1 2 3

7
Wejście NSB
w regulatorze SLAVE SL
VS30B
VS30W
L
S1
S2
N
L
AC 230V
N
T30NC
Wyjście NSB
KL08 NSB
L
S1
S2
N
L
SL
NSB
SL
N
VS30B
VS30W
L, N - power supply 230V
- NSB - Night temperature reduction
(230V output)
-SL - 230 V AC output signal
S1, S2 - additional temperature sensor
eg. FS300
2.3 Connection description
NSB input in
SLAVE thermostat
NSB output
Legend:
Thermal actuator
Temperature sensor
Symbols explanation:
T

8
THB23030 PUMP (optional)T30NC230 BOILER
4 wires x 0.75 mm
4 wires x 0.75 mm
Power Supply
230V AC
Actuators wires
2 x 0.75 mm Pump control wires
2 x 1 mm Boiler control wires
2 x 1 mm
KL08NSB KL04NSB (optional)
SLAVEMASTER
VS30W/VS30B VS35W/VS35B VS35W/VS35B
I A - 4 wire installation with KL08NSB wiring centre
When VS30W/VS30B thermostat works as a MASTER (group controller) it means it takes control of SLAVE thermostats e.g. VS35W.
MASTER thermostat controls SLAVE thermostat only when SLAVE thermostat is in AUTO mode. Comfort (SUN) and economy (MOON) setpoint
temperatures are set individually on each thermostat but switching between those temperature is based on time schedule taken from VS30W/VS30B
thermostat which works like a group controller. Functions such as: setpoint temperature change, holiday mode, party mode or frost protection mode are
not managed by MASTER thermostat.

9
SLAVEMASTER
L
AC 230V
L
N
N
1 - 8 Strefy 1 - 8 Strefy 1 - 8 Strefy
KL08NSB
Pump BoilerPower
L N
SL
T30NC
L N
SL
T30NC
L N
SL
T30NC
lu ub
VS30 RT200 RT520
L L L
L
or or
L
1 2 BOILER CONNECTION*
1-8 Zones1-8 Zones1-8 Zones
3 4
N N N
N N
N
L
max 6
per zone max 6
per zone max 6
per zone
VS30W/VS30B VS35W/VS35B VS35W/VS35B
L, N - power supply 230V
- NSB - Night temperature reduction
(230V output - in MASTER thermostat)
(230V input - in SLAVE thermostat)
-SL - 230 V AC actuator control signal
- fuse
Legend:
Symbols explanation:
Thermal actuator
Pump
Boiler - Boiler connection* - Boiler’s
contacts for ON/OFF thermostat
(according to the boiler’s instructions)

10
I B - 4 wire installation with KL06 wiring centre
THB23030T30NC230
Power Supply
230V AC
Actuators wires
2 x 0.75 mm Pump control wires
2 x 1 mm Boiler control wires
2 x 1 mm
KL06 PL07 PL06
PUMP (optional) BOILER
4 wires x 0.75 mm
4 wires x 0.75 mm
SLAVEMASTER
VS30W/VS30B VS35W/VS35B VS35W/VS35B
Este manual sirve para los siguientes modelos
4
Tabla de contenidos
Otros manuales de Termostato de Computime

Computime
Computime SALUS Controls AT10 Manual de usuario

Computime
Computime Salus Controls iT500 Manual de usuario

Computime
Computime GES2181 Manual de usuario

Computime
Computime SALUS Controls HTR230 Manual de usuario

Computime
Computime Salus Controls RT310SR Manual de usuario

Computime
Computime Salus Controls RT310SPE Manual de usuario
Manuales populares de Termostato de otras marcas

EWELLY
EWELLY EW-181 Manual de usuario

Prolon
Prolon T1100 Instrucciones de instalación

Computherm
Computherm Q20 Manual de usuario

Heatmiser
Heatmiser neoStat Manual de usuario

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Manual de usuario

Mars
Mars HEAT CONTROLLER IR Wireless Thermostat Manual de usuario