Como Open Therm Manual de usuario

Como OT
Open Therm Room
Temperature Controller
Installation and
Operating Manual
Please observe the safety instructions and
read through this manual carefully before
commissioning the equipment.
12:47

Safety information General information
2
General infor mation
Safety information
Power connection regulations
Please note the connection conditions specified by your
local electrical power supply company and the VDE
regulations.
Your heating control system may be installed and serviced
only by appropriately authorized specialists.
EIf the system is not installed properly, there is a risk of
fatal or severe personal injury.
Warranty conditions
If the system is not installed, commissioned, serviced and
repaired properly, it will render the manufacturer's warranty
null and void.
Important text
!Important information is highlighted with an
exclamation mark.
EThis attention symbol indicates dangerous situations.
Installation
Information on installation and starting the equipment up
as well as a connection diagram are provided in Part 3 of
this manual.
Description
Declaration of conformity
This device corresponds to the requirements of the
relevant guidelines and standards, if the corresponding
installation regulations and the manufacturer’s instructions
are complied with
Function
The controller enables setting and measuring values to be
entered and displayed for the heating system in the user's
living room. This means that the heating system can be
monitored and optimized constantly. Use of this controller
also enables the room temperature to be regulated and
displayed directly.
!The following information only applies when the
boiler type connected can send and receive the
necessary data on the BUS. Dotted lines, for
example, appear in the display for data which is not
available.

General information Description
3
General information 2
Safety information 2
Power connection regulations 2
Warranty conditions 2
Important text 2
Installation 2
Description 2
Declaration of conformity 2
Function 2
Part 1: Operation 4
Operation in normal mode 4
Mode selector switch 4
ECO key (heating time interruption) 5
Party key (heating time extension) 5
Modifying the set room temperature 6
Display in normal mode 6
Changing the settings 7
Overview of set value levels 8
Overview of user values 9
Overview of display messages 10
Enter time and weekday 11
Enter heating programs 12
Timer/heating program adjustment 12
Enter holiday program 14
Overview of expert values 15
Overview of code-protected valued 16
TSP - Transparent Slave Parameters 17
FHB - Fault History Buffer 17
Part 2: Explanations / Functions 18
Explanation of the set values 18
In the event of problems 20
Reset 20
Error display 20
General error list 21
Error 81 21
Other error numbers 21
Communication with the boiler " " 21
Unlocking the boiler 21
Pump runs / runs not => automatic
Pump switching 21
Part 3: Installation and Starting Up 22
Installation 22
Starting up 23
Communication OK? 23
Set language 23
Set time and weekday 23
Switching on the heating via telephone 24
Technical data 24

Operation in normal mode Part 1: Operation
4
Part 1: Operation
Operation in normal mode
(Hinged control panel cover closed)
Operating mode selector switch
ECO key (interruption of heating time)
Party key (heating time extension)
Modification of set room temperature
Mode selector switch
Press the key as often as necessary to set the operating
mode required. The selected operating mode is
represented by a symbol in the display. It takes effect
when the selected setting remains unchanged for 5 sec.
The following operating modes are available for selection:
iStandby / OFF
(heating and hot water preparation OFF,
only frost protection function active)
F1 Automatic mode
(heating according to time program 1)
F2 Automatic mode
(heating according to time program 2)
hDay mode
(24 hour heating at comfort temperature 1)
CNight mode
(24 h heating at economy temperature)
FSummer mode
(heating OFF, only hot water preparation active)

Part 1: Operation Operation in normal mode
5
ECO key (heating time interruption)
B
Displays (for approx. 3 sec.) the set interruption of the
heating time => Heating at economy temperature [ B]
Party key (heating time extension)
B
Displays (for approx. 3 sec.) the set extension of the
heating time => Heating at comfort temperature [ B]
Use to start setting/display / set duration of
heating time interruption
press => + 1 hour for each actuation
press => - 1 hour for each actuation
press 3 seconds:
Heating circuit switches to economy mode for the
rest of the day.
Display switches briefly to "ECO"
Use to start setting/display / set extension of
heating time
press => + 1 hour for each actuation
press => - 1 hour for each actuation
press 3 seconds:
Heating circuit heats until the next day.
Display switches briefly to "PARTY"
End the set Party or ECO function by pressing the Mode selector switch

Operation in normal mode Part 1: Operation
6
Modifying the set room temperature
In Normal mode, the heating system operates according to
the set room temperature (default, 20°C / 68°F).
Display in normal mode
!Due to inertia of the room temperature, deviations of
+/- 1°C / 2°F to the required room temperature are
normal. During transition from reduced operation
and heating operation, greater deviations are
possible at times.
Use the rotary knob to adjust the set room temperature by
±5°C / 9 °F. The nighttime temperature (economy
temperature) set on the controller is not affected.
Turn clockwise => Warmer (~1°C / 2°F per dot)
Turn counterclockwise => Colder (~1°C / 2°F per dot)
A Current time
B Set room temperature
(represented in degrees Celsius / Fahrenheit)
C Day (1=Monday, 2=Tuesday, ..., 7=Sunday)
(here, 3 = Wednesday)
D Bus symbol (if this symbol does not appear, check
the data cable to the boiler)
E Indicates the active heating program
(here: 6:00 to 9:00 and 14:00 to 23:00)
F Status indicator: Hburner ON; ZDheating
operation; ZFhot water preparation; frost pro-
tection active
G Mode selector switch
(here F1 => Heating according to time program 1)
H Mode indicator and current status
(here: BII => Heating with set room temperature 2)
I Display of the current room temperature

Part 1: Operation Changing the settings
7
Changing the settings
Changing the settings
ÄProgramming key
a) Select a value level
b) Select a value to be changed
c) Saving the new value
Plus key
(Search for or change value)
Minus key
(Search for or change value)
Operating and changing modes are accessed
directly by opening the control panel cover. =>
USER in the display
/Use the Plus/Minus keys to select the level in
which the value to be changed is located
=> Overview on the following pages
ÄPress the Prog key => Open / Select the level
/Use the Plus/Minus keys to locate the value
=> Overview on the following pages
ÄPress the Prog key => Select the value
Warning triangle appears in the display
=> Value can be changed
/Use the Plus/Minus keys to change the value
either => Do not save the value
òClose the control panel cover =>
ECaution! The changed value is not saved.
or => Save the value
ÄPress the Prog key => Value is saved
Warning triangle disappears from the display and
then
òClose the control panel cover
~

Part 1: Operation
8
~OPEN cover search for level using /
Overview of set value levels
•USER
Values are set by the user
•DISPLAY
Display temperatures in the system
•TIME-DATE
Set the time and weekday
•HTG-PROG 1
Set the 1st heating program (e.g. for working day)
•HTG-PROG 2
Set the 2nd heating program (e.g. for holiday)
•HOTW-PROG
Set the hot water program
•HOLIDAY
Set the start and duration of the holiday period
•EXPERT
Values should be set by a trained fitter
USER => See Page 9
DISPLAY => See Page 10
TIME-DATE => See Page 11
HTG-PROG 1 => See Page 13
HTG-PROG 2 => See Page 13
HOTW-PROG => See Page 13
HOLIDAY => See Page 14
EXPERT => See Page 15

Part 1: Operation
9
Overview of user values
USER
T-ROOM DES 1 5°C - 40°C => 20°C /
41°F -104°F => 68°F Value:
T-ROOM DES 2 5°C - 40°C => 20°C /
41°F -104°F => 68°F Value:
T-ROOM DES 3 5°C - 40°C => 20°C /
41°F -104°F => 68°F Value:
T-REDUCED 5°C -40°C => 10°C /
41°F -104°F => 34°F Value
T-ABSENCE 5°C -40°C => 15°C /
41°F -104°F => 59°F Value
T-DHW 1 10°C - 70°C => 50°C /
50°F -158°F => 122°F Value:
T-DHW 2/3
(
onl
y
with tank
)
10°C - 70°C => 50°C /
50°F -158°F => 122°F Value:
MAX T-HS 30°C-110°C => 85°C /
86°F -230°F => 185°F Value:
MAX T-FLOW
(
onl
y
with 2nd HC
)
30°C-110°C => 85°C /
86°F -230°F => 185°F Value:
MAX MODULATI 0-100 => 100% Value:
°C / °F °C - °F => °C Value:
RETURN
T-ROOM DES 1-3
Set room temperature for the 1.,2. or 3. heating period
T-REDUCED
Set room temperature for the night
T-ABSENCE
Set room temperature for the holiday period
T-DHW 1
Set hot water temperature for the first hot water period
T-DHW 2/3
Only for use in operation with an external hot water tank:
Set hot water temperature for the second hot water period
MAX T-HS
Maximum temperature of the boiler in heating operation:
Limitation for saving energy possible
MAX T-FLOW
Only with 2nd heating circuit: maximum flow temperature
of the mixing circuit (heating circuit 2 => protection)
MAX MODULATI
Maximum modulation factor of the boiler in heating
operation: Output limitation of the boiler for saving energy
°C / °F
Unit of the temperature

Part 1: Operation
10
T-OUTSIDE
(only with outdoor sensor connected [Terminals 5+6]) Display of the current outside
temperature [°C / °F] Ä=> Max. value with time; => Min value with time;
=> Max. value with time; Ä=> RETURN
T-ROOM DES
Display of the current room temperature [°C / °F]
Ä=> Current set temperature; => Min value with time; => Max value with time;
Ä=> RETURN
T-DHW
Display of the current hot water temperature [°C / °F] (only in hot water tank mode)
Ä=> Current set temperature; Ä=> RETURN
T-HS
Display of the current boiler temperature [°C / °F] Ä=> Current set temperature; Ä=>
RETURN
T-FLOW
Only with 2nd heating circuit: Displays the current flow temperature of the 2nd heating cir-
cuit [°C / °F] Ä=> calculated value; Ä=> RETURN
MODULATION
Display of the current boiler output [%]; 00 = OF or value is not being sent
BURNER TIME
Display of the current burner operating hours [h] Ä=> Set value to ZERO; Ä=> RETURN
BURNER START
Display of the current burner start of the boiler [x] Ä=> Set value to ZERO; Ä=>
RETURN
WATER PRESS
Display of the current water pressure in the boiler (0.0 => value is not being sent)
RETURN Ä=>RETURN to main menu
Overview of display messages
DISPLAY
T-OUTSIDE
T-ROOM DES
T-DHW
T-HS
T-FLOW
MODULATION
BURNER TIME
BURNER START
WATER PRESS
RETURN