Nurse call function JNS-70MN
User Manual
www.safemag.ru
www.safemag.ru

2
Contents
1. Nurse call function
Main screen composition ................................................................................................. 4
Conversation with an inpatient ...................................................................................... 5
Receiving a call from an inpatient ................................................................................ 7
Staff Call funtion ................................................................................................................ 10
Emergency situation function ...................................................................................... 11
Simultaneous situation function ................................................................................. 13
Broadcasting function ..................................................................................................... 14
Smart control function .................................................................................................... 16
Searching the bed ............................................................................................................ 17
Designating the bed group .......................................................................................... 19
Deleting the bed ............................................................................................................... 23
Recent calls .......................................................................................................................... 24
Bed designation in charge ............................................................................................ 25
Setting the bed, group number .................................................................................. 38
2. Configuration
Setting the environment ....................................................................................... 41
Users notice
A class equipment
(Broadcasting communication
equipment for business)
Sellers or users should be advised of this
equipment as the equipment suitable for
electromagnetic waves for business use (A class)
and it aims at usage in region except house.
www.safemag.ru
www.safemag.ru

3
Chapter 1. Nurse call function
1. Main screen composition
2. Conversation with an impatient
3. Receiving a call from an impatient
4. Staff call function
5. Emergency situation function
6. Simultaneous situation function
7. Broadcasting function
8. Smart control function
8-1. Searching the bed
8-2. Designating the bed group
8-3. Deleting the bed
8-4. Recent calls
8-5. Bed designation in charge
9. Bed, group number setting
www.safemag.ru
www.safemag.ru

4
I. Main screen composition
Main screen
①, ② Page movement
③ Room number
④ Bed number
⑤ Whole broadcasting
⑥ Group broadcasting
⑦ Smart control
⑧ Remote control
③ ④
①②
⑤ ⑥⑦
⑧
www.safemag.ru
www.safemag.ru

5
II. Conversation with an inpatient
1. Using the speed dial (After setting the bed number)
1. Pick the receiver or press the speaker button in front.
2. After pressing the relevant room number, press the bed
number. Then, you can speak with by calling the relevant
patient. (In case of speaker phone mode, you can speak
with if you pick the handset.)
Screen using the speed dial
* , By pressing (①, ②), you can check the bed
numbers of previous and next rooms. (If 12 rooms, 8 beds are
inputted, max 24 rooms, 16 beds are set.)
①②
www.safemag.ru
www.safemag.ru

6
2. Using dial button
1. Pick the handset or press the speaker button in front.
2. After entering the relevant room number with the button
in front, press the asterisk(*). If you press the pound
button (#) after entering bed number, you can speak
with the relevant patient by calling him or her. (In case
of speaker phone mode, you can speak with if you pick
the handset.)
Screen using number button
www.safemag.ru
www.safemag.ru

7
III. Receiving a call from an inpatient
1. Request of an inpatient call
1. The number of bed and room requesting call are
displayed as green and yellow wall paper is switched.
Call request screen
2. If you pick the handset or press the speaker phone
button, the number of bed and room requesting call
are displayed.
Incoming progress screen
www.safemag.ru
www.safemag.ru

8
2. Seeing the stand-by call list (in case of offering bed
call function)
If there’s call request from another bed during the
conversation with a patient, stand-by call list will be
shown.
If you select the stand-by list while talking, previous
call will be ended and conversation with selected
bed will be started. Stand-by list will disappear when
the conversation has done.
Seeing stand-by call list
www.safemag.ru
www.safemag.ru

9
3. Outside call(IP-Phone) function(Option function)
During the nurses’ absence in the nurse station, call
request is delivered by the information of nurse and
schedule registered in the server(IP-PBX) to the
nurse’s cell phone. Once the nurse get the phone, a
main receiver is displayed the number of bed on a
screen. In a main receiver, outside call should be
ended in order to use call function.
Mark of outside call
* This function is needed additional devices such as IP-PBX,
Media Gateway for its use.
www.safemag.ru
www.safemag.ru

10
IV. STAFF CALL function
In case that the nurse judges the situation as emergency
when the nurse presses the presence switch from
patient’s call and visits the bed of the patient, in a bed if
you try call request on the screen of main receiver in a
nurse station the number of bed and emergency sound
will break out. (Same as call request screen)
Call request screen