3
Introduction.....................................................................................................................................4
RFID sensing area.........................................................................................................................4
Screen: Code entry.......................................................................................................................4
Indications.......................................................................................................................................5
Buzzer...........................................................................................................................................5
Key to indicator LEDs.....................................................................................................................5
Main screen.....................................................................................................................................6
System status..................................................................................................................................6
Alarm or tampering alert screen...................................................................................................7
Quick commands from the home scen........................................................................................7
Arming.............................................................................................................................................7
Disarming........................................................................................................................................7
Arming with zones open................................................................................................................8
Arming with zones excluded.........................................................................................................8
Arming with zones isolated...........................................................................................................9
Arming while faults are present....................................................................................................9
Arming while tampering is present...............................................................................................9
Using the RIFD key.........................................................................................................................9
System options.............................................................................................................................10
Zonestatus.....................................................................................................................................11
Users..............................................................................................................................................11
Event log........................................................................................................................................12
Telephone contacts list................................................................................................................12
Areastatus......................................................................................................................................12
Output commds.............................................................................................................................13
Quick commds..............................................................................................................................14
Quick command selection buttons on the main screen...........................................................14
App launch.....................................................................................................................................15
Alarm options................................................................................................................................16
Enable installer..............................................................................................................................16
Register key..................................................................................................................................16
Delete key......................................................................................................................................17
Timer..............................................................................................................................................18
Auto arming...................................................................................................................................18
Configuration................................................................................................................................18
Configuration menu....................................................................................................................18
Device ID.....................................................................................................................................19
Device Password........................................................................................................................19
User code..................................................................................................................................19
BUS485 speed............................................................................................................................20
Backlighting level........................................................................................................................20
Screen lock.................................................................................................................................20
Reset configuration.....................................................................................................................21
Information..................................................................................................................................21
Manufacturing test......................................................................................................................21
Emulated keypad........................................................................................................................21
Table of contents

4
Introduction
VEDO5TPR is a keypad with 5” touchscreen that is compatible with all sizes of Vedo control panels.
Thanks to its many functions, it can be used to arm and disarm the system, check the status of the system and
its areas and zones, and to view the users associated with the control panel and its telephone contacts list.
The event log section can also be used to view the event and alarm logs.
RFID sensing area
(for alarm arming/disarming using an
authentication key and user ID)
Screen: code entry
To carry out procedures, you must log in with a user code and/or an RFID key. When the code is required, the
following screen will appear:
Enter the code (6 digits) and then press to confirm, to cancel.
OR:
hold the key next to the scanning zone to enter the code and perform authentication.
IMPORTANT: en combinación con un nuevo panel de control aún en fase de programación, solo el usuario 1
está activo con el código "111111".
IMPORTANT: if the screen is not touched for one minute, it will switch off and enter energy saving mode.

5
Alerts
Buzzer
The buzzer integrated into the VEDO5TPR beeps when any valid key is pressed. Furthermore, depending on
the options selected during the programming stage, the buzzer can signal:
Beep* Alerts
• Key pressed
— (1 sec.) Arming confirmed
— (2 sec.) Total disarming confirmed
•••••••• (2 sec.) Failed arming
•••••••••••••••••••• At least one zone is in alarm condition
•••••••••••••••••••• At least one zone is in "pre-alarm" condition (time period between zone viola-
tion and Alarm event generation).
• • • • • • • • • • • • Automatic arming pre-alert time
• • • • • • • • • • • • At least one zone is in "Exit time" condition
• • • • • • • • • • At least one zone is in "Entry time" condition
•·•·•·•·•·•·•·•·•·•·•·•·•· Signals that a zone with the chime attribute (zone opening alert chime) has
been opened. The buzzer is activated only if the violated zone is not armed
• • • • • • • • • • • • • Waiting for key to be presented for acquisition of RFID key
*The symbol "•” represents a short beep, the symbol “—” represents a long beep. The distance between the
“•” symbols represents the time frequency of the beeps. The size of the symbols represents the relative volume
of the beeps “•·”
Key to indicator LEDs
VEDO5TPR has a series of three LEDs in different colours on the front panel, which function as follows:
Colour Signal
Green ON System armed
Flashing green System not ready
Green OFF System ready
Yellow ON Problem detected
Flashing yellow Presence of isolated, excluded or inhibited zones, or of temporarily excluded
anomalies/sabotages
Yellow OFF No fault detected
Red ON System in alarm
Flashing red Alarm log
Red OFF No alarm detected

6
Main screen
To access the main screen, simply touch the screen if it is off, or use the relevant icons if you are already
accessing the menus.
The main screen appears as shown in the figure,
where the areas present in the control panel are
indicated. You can click on the description of
each area, or tap the centre of the circle to arm or
disarm the system (after entering the user code).
The key to colours (shown in the table below)
indicates the status of each zone.
You can also use the arrow pointing right to
navigate to the second page listing the quick
commands.
IMPORTANT: the screen will switch off after 30 seconds of inactivity (1 minute for the password entry screen)
and energy saving mode will be activated.
System status
The “System status” icon changes colour depending on the status of the system.
System armed
System part armed
System ready for arming
System NOT ready for arming (zones open...)
System NOT ready for arming (system faults...) Flashing padlock icon
System armed and in alarm condition
System in alarm condition due to tamper sabotage or panic alarm when unarmed
Alarm memory (system armed). Flashing padlock icon
Alarm memory (system unarmed). Flashing padlock icon
Moreover, in the event of faults and/or anomalies on the screen, the cause will also be shown. The image
below is an example of a device fault:

7
Alarm or tampering alert screen
In the event of alarms or sabotage, when the system is armed, a screen with a red background will appear
indicating the event. In this example, with the system armed, a “Burglary” type alarm is occurring.
The information will then remain available for reference within the “Event log” in the menu.
Quick commands from the home screen
The quick commands screen is easy to reach by pressing the arrow in the bottom right-hand corner of the
home screen.
The list of possible scenarios is shown on the left. On the right, the following quick commands appear by
default (*):
-Stop alarm
-Reset alarm
-Enable installer
*Refer to the “Quick Commands” section for further information regarding the customisation of icons available
on the home screen
Arming
If the system is unarmed, a full arming of all areas can be carried out by tapping the centre of the circle on the
main screen.
Conversely, if a specific area needs to be armed, you can click on its description or the corresponding part of
the circle.
If activated, the system can still be armed by means of a specific scenario.
Disarming
If the system is armed, a full disarming of all areas can be carried out by tapping the centre of the circle on the
main screen.
Conversely, if a specific area needs to be disarmed, you can click on its description or the corresponding part
of the circle.
If activated, the system can still be disarmed by means of a specific scenario.

8
Arming with zones open
If a zone is open during arming, and is not delayed and not available for exclusion, after the system analysis
screen, the following screen will appear:
If you press “Forcing” the system will be armed but the presence of an inhibited zone will be indicated by
the LED flashing (inhibited status will remain until the next system disarming). Press “Cancel” to cancel the
operation.
On the other hand, if the open zone has previously been set as not available for exclusion (action performed
using Safe Manager software), the following screen will appear:
Arming with zones excluded
If a zone is excluded during arming (and set as not available for exclusion), after the system analysis screen,
the following screen will appear, indicating how the system can be armed:

9
Arming with zones isolated
If a zone is isolated during arming, after the system analysis screen has been shown the following screen will
appear. It can be used to activate the zone, cancel the procedure, or continue to maintain isolation status
(forcing), as shown below:
Arming while faults are present
If a fault is present during arming, after the system analysis screen has been shown the following screen will
appear, indicating the fault and the option of forcing it (inhibiting it) to arm the system.
On the other hand, you do not possess the necessary authorisation for system arming (forced arming level 2),
the following screen will appear.
IMPORTANT: for information regarding these authorisations please contact your installer.
Arming while tampering is present
If a tampering event is present during arming, the system will behave in the same way as when a fault is
present (alarm alert or tampering present screen on page 6). If you attempt to confirm the arming without
permission, the “Act. locked” screen will appear.
Using the RFID key
With the RFID key you can:
Carry out a full system Arming / Disarming procedure by passing the key near the RFID sensor or additional
actions such as reset alarms, access the settings menu...
Full arming/disarming using the key is not possible during the device update procedure, the key
programming procedure or within the password entry screens.

10
»Scanning the key will be followed by the “System analysis” screen, then an “Arming executed” or
“Disarming executed” screen depending on the system status.
»If faults, open zones or tampering events are present during arming, the procedures described in the
paragraphs above will apply.
»If the key is not memorised in the system, the following screen will appear:
System options
The system options can be accessed from the homepage screen by clicking the icon in the top left corner.
Once the user code has been entered, the menu with its various options will be shown:
The system options menu includes the following entries:
• Zone status
• Users
• Event log
• Telephone contacts list
• Area status
• Output commands
• Quick commands
• App launch
• Alarm options
• Emulated keypad
The icon allowing access to the VEDO5TPR user manual through the scanning of a QR code is also
present.
Otros manuales para VEDO5TPR
1
Tabla de contenidos
Otros manuales de Pantalla táctil de Comelit
Manuales populares de Pantalla táctil de otras marcas

Elecro Engineering
Elecro Engineering Poolsmart Plus Instrucciones de instalación

Johnson Controls
Johnson Controls IQ4 HUB Manual de usuario

Elo TouchSystems
Elo TouchSystems ET2270L Manual de usuario

Elo TouchSystems
Elo TouchSystems ET1002L Manual de usuario

Elo TouchSystems
Elo TouchSystems 3201L Manual de usuario

Duratec
Duratec S15 Manual de usuario