Coemar CF 1200 Hard Edge Manual de usuario

CF 1200
2nd edition, november 1999
instruction
manual

CF 1200
numero di serie/serial number
data di acquisto/date of purchase
fornitore/retailer
indirizzo/address
cap/città/suburb
provincia/capital city
stato/state
tel./fax/
Prendete nota, nello spazio apposito, dei dati relativi al modello e al rivenditore del vostro
CF 1200
: in caso di
richiesta di informazioni, pezzi di ricambio, servizi di riparazione o altro ci permetteranno di assistervi con la mas-
sima rapidità e precisione.
Please note in the space provided above the relative service information of the model and the retailer from
whom you purchased your
CF 1200
: This information will assist us in providing spare parts, repairs or in
answering any technical enquiries with the utmost speed and accuracy.
ATTENZIONE: la sicurezza dell’apparecchio è garantita solo con l’uso appropriato delle presenti istruzioni, per-
tanto è necessario conservarle.
WARNING: the security of the fixture is granted only if these instructions are strictly followed; therefore it is
absolutely necessary to keep this manual.
514 mm
692 mm
750 mm
204 mm
306 mm
592 mm 546 mm

Index
1. Packaging
2.Transporting
3.Important safety information
4. Lamp: installation and replacement
5. Operating voltage and frequency
6. Mounting the unit
7. Mains connection
8. Signal connection
9.Powering up
10.DMX addressing
11.Display panel functions
11.1. Powering up the CF 1200 with movement disenabled
12.Control channel functions from a DMX 512 controller
13.Aligning the lamp in the optical system
14.Interchanging dichroic colours on the colour wheel
15.Automatic internal functions
16.Maintenance
17.Electronic alignment of the motors
18.Spare parts

Congratulations on having purchased a new coemar product; you have assured yourself of a fixture of the highest quality,
both in the components used and in the technology. We renew our request to you to complete the service information on the
preceding page, to expedite any request for information, or for service (in case of problems encountered either during, or sub-
sequent to, installation). This information will assist in prompt and accurate advice from your authorised coemar service centre.
1. Packaging Following the instructions contained in this manual will ensure the maximum effi-
ciency of this product for years to come.
Open the packing and ensure that no part of the equipment has suffered damage in
transit. In the case of damage to the equipment, contact the carrier immediately by
telephone or fax, following this with formal notification in writing.
packing list
Ensure that the packaging contains:
1 CF 1200
1 instruction manual
2. Trasporting The CF 1200 should always be transported in its original packaging or in a coe-
mar approved flight case.
In order to manufacture a suitable flight case, we recommend the following simple
procedures be followed which will stop the articulated movement of the CF 1200
during transportation.
Below are illustrated the 2 diverse methods of padding which coemar recommends.
A) Padding around the entire projector, including the base, with suitable padding
materials.
B) Fixing the base to a rigid support, with padding surrounding the articulated head.
Polietilene
espanso/
Foam
Pomoli di
bloccaggio/
Knobs
Polietilene
espanso/
Foam

3.Important safety Fire prevention
information 1. CF 1200 uses a Philips MSR 1200 SA lamp; the use of any alternative lamp i s
not recommended and will null and void the fixture’s warranty.
2. Never locate the fixture on any flammable surface
3. Minimum distance from flammable materials: 0.5 m.
4. Minimum distance from the closest illuminable surface: 2 m.
5. Replace any blown or damaged fuses only with those of identical values. Refer to
the schematic diagram if there is any doubt.
6. Connect the projector to mains power via a thermal magenetic circuit breaker.
Prevention of electric shock:
1. High voltage is present in the internals of the unit. Isolate the projector from
mains supply prior to performing any function which involves touching the inter-
nal of the unit, including lamp replacement.
2. For mains connection, adhere strictly to the guidelines outlined in section 7 of this
manual.
3. The level of technology inherent in the CF 1200 requires the use of specialised
personnel for all service applications; refer all work to your authorised coemar
service centre.
4. A good earth connection is essential for proper functioning of the projector.
The projector should never be operated without proper earth connection.
5. The fixture should never be located in an exposed position, or in areas of extreme
humidity. A steady supply of circulating air is essential.
Protection against ultraviolet radiation:
1. Never turn on the lamp if any of the lenses, filters, or the carbon fibre housing is
damaged; their respective functions will only occur efficiently if they are in perfect
working order.
Never look directly into the lamp when it is operating.
Safety:
1. The projector should always be installed with bolts, clamps, and other fixings
which are suitably rated to support the weight of the unit.
2. Always use a secondary safety chain of a suitable rating to sustain the weight of
the unit in case of the failure of the primary fixing point.
3. The external surface of the unit, at various points, may exceed 150°C. Never
handle the unit until at least 10 minutes after the lamp has been turned off.
4. Always replace the lamp if any physical damage is evident.
5. Never install the fixture in an enclosed area lacking sufficient air flow; the ambient
temperature should not exceed 35°C.
6. The hot lamp may explode, always wait at least 10 minutes after it has been tur-
ned off prior to attempting to replace or handle the lamp.
Always wear suitable hand protection when handling the lamp.

4. Lamp: Installation CF 1200 utilises a 1200 W Philips MSR 1200 SA lamp.
and replacement with a GY 22.lamp base
The lamp is available from your authorised coemar sales agents:
coemar cod. 105090/1
wattage 1200 w
luminous flux 96.000 lm
colour temperature 6500° K
base GY 22
approximate life 500 hours
The fixture’s internal temperature can reach 250° C after 5 minutes, with a maximum
peak of 350° C; ensure that the bulb is cold before attempting removal. The fixture
should be allowed to stand and cool for 10 minutes prior to its removal.
MSR/SA lamps are part of the mercury vapour family of discharge lamps and must be
handled with great care. The lamp operates at high pressure, and the slight risk of
explosion of the lamp exists if operated over its recommended life of 500 hours.
We recommend, therefore, that the lamp be replaced within the manufacturer’s spe-
cified lamp life.
lamp installation
1) With the use of a 3mm Allen Key, loosen the two bolts (A) which fix the lamp
assembly to the body of the projector.
2) Remove the lamp assembly (B).
3) Locate the lampholder (C)
Attention
Disconnect mains power prior to inspecting the unit internally.

4) Insert the lamp (D). The lamp used is manufactured from quartz glass and should
be handled with care; always adhere to the instructions supplied in the lamp’s
packaging. Do not touch the glass directly, the the tissue provided in the lamp
packaging. The GY 22 lampholder is assymetrical in construction. One lamp pin is
larger than the other; therefore make sure that the lamp’s pins are correctly ali-
gned in the lampbase. If you encounter difficulty during this operation, DO NO
USE UNDUE FORCE. Re-read the instructions and repeat the procedure.
5) Replace the lamp assembly (B) in its original position and replace the two bolts
(A) which were previously removed.
Attention: we recommend that the lamp be realigned in the optical train of the
unit to avoid overheating the dichroic filters within the unit; refer to section 13 for
instructions about this procedure.

5. Operating voltage coemar factory presets (barring specific requests), a voltage of 230v to 240v
and frequency selectable via a switch on the base of the CF 1200.
Remember to set the selector (230 or 240V) to the selection which most closely matches
the operating voltage at your venue.
If your operating voltage is 208V, this may be selected internally by shifting the cable
labelled 21 (connected to the 240V position of the switch) or cable 22 (connected to
the 230V switch), thereby, however, eliminating the ability to select either 230V or
240V.
Incorrect voltage selection will detrimentally affect the operation of
the projector. Under no circumstances should cable 23 be moved.
CF 1200 is fitted with an electronic ballast which automatically adjusts the output
voltage to the projector when the input voltage is in the range of 180 to 260V; it is
therefore not necessary to make any modifications when moving to venues with
power supplies in this range.
115V
208V
230V
240V
23
Bianco/White
Nero/black 230V
Rosso/red 115 V
Blu/blue 240V
Giallo/yellow 208 V
22
21
c
oemar set
main at:
115V
208V
230V
240V
230V
coemar set
main at:
115V
208V
230V
240V
240V

6. Mounting the unit mounting
CF 1200 may be floor or ceiling mounted. The structure from which the unit is
hung should be of sufficient rating to hold the weight of the unit, as should any
clamps used to hang the unit.
The structure should also be sufficiently rigid so as not to move or shake whilst the
CF 1200 moves during its operation.
The mouting holes in the base of the unit allow it to be mounted at various angles to
the mounting truss, and to trusses of various dimensions.
The following is a diagram of the base of the CF 1200 Spot.
165mm
165mm
455mm
n°6 asole 72x12 mm r= 6 mm

In order to obtain maximum efficiency of movement, the unit should be mounted
with the ” Front” label facing the main illumination point.
protection against liquids
The projector contains electric and electronic components that must not come into
contact with water, oil, or any other liquid.
moviment
The projector has a movement of 370° in the base and 270° in the yoke; DO NOT
place any obstructions in the path of the projector’s movements.
safety chain
The use of a safety chain (cod. 069) - fixed to the CF 1200 and to the primary
suspension point, is highly recommended to protect against accidental failure,
however unlikely, of the primary suspension point.
If using an after-market safety chain, not manufactured by coemar, ensure that it is
of sufficient strength to hold the weight of this fixture.
risk of fire
Each fixture produces heat and must be installed in a well-ventilated position. The
minimum recommended distance from flammable material is: 0.5m. Minimum
distance from the object being illuminated is: 2m.