CMX VS-C200 Manual de usuario

1/13
VS-C200
VS-C200
User
User Manual
Manual
INSTALLATION
INSTALLATION AND
AND OPERATION
OPERATION MANUAL
MANUAL

2/13
Important note
Warning
In order to ensure the reliable performance of the equipment and the safety of the user, please
observe the following matters during the process of installation, use and maintenance:
◆Please do not use this product in the following places: the place of dust, soot and electric
conductivity dust, corrosive gas, combustible gas; the place exposed to high temperature,
condensation, wind and rain; the occasion of vibration and impact . Electric shock, fire, wrong
operation can lead to damage and deterioration to the product, either;
◆In processing the screw holes and wiring, make sure that metal scraps and wire head will not
fall into the shaft of controller, as it could cause a fire, fault, or incorrect operation;
◆When the installation work is over, it should be assured there is nothing on the ventilated face,
including packaging items like dust paper. Otherwise this may cause a fire, fault, incorrect
operation for the cooling is not free;
◆Should avoid wiring and inserting cable plug in charged state, otherwise it is easy to cause the
shock, or electrical damage;
◆The installation and wiring should be strong and reliable, contact undesirable may lead to false
action;
◆For a serious interference in applications, should choose shield cable as the high frequency
signal input or output cable, so as to improve the anti-jamming ability of the system.
Attention in the wiring:
◆Only after cutting down all external power source, can install, wiring operation begin, or it may
cause electric shock or equipment damage;
◆This product grounds by the grounding wires .To avoid electric shocks, grounding wires and the
earth must be linked together. Before the connection of input or output terminal, please make
sure this product is correctly grounded;
◆Immediately remove all other things after the wiring installation. Please cover the terminals of
the products cover before electrification so as to avoid cause electric shock.
Matters needing attention during operation and maintenance:
◆Please do not touch terminals in a current state, or it may cause a shock, incorrect

3/13
operation;
◆Please do cleaning and terminal tighten work after turning off the power supply. These
operations can lead to electric shock in a current
state;
◆Please do the connection or dismantle work of the communication signal cable , the expansion
module cable or control unit cable after turning
off the power supply, or it may cause damage to the equipment, incorrect operation;
◆Please do not dismantle the equipment, avoid damaging the internal electrical component;
◆Should be sure to read the manual, fully confirm the safety, only after that can do program
changes, commissioning, start and stop operation.
Matters needing attention in discarding product:
◆Electrolytic explosion: the burning of electrolytic capacitor on circuit boards may lead to
explosion;
◆Please collect and process according to the classification, do not put into life garbage;
◆Please process it as industrial waste, or according to the local environmental protection
regulations.

4/13
Table of Contents
1 Product Description....................................................................................................................... 5
2 Features........................................................................................................................................... 5
3 Typical Application.........................................................................................................................6
4 Specifications.................................................................................................................................. 7
5 Hardware Description....................................................................................................................8
5.1 Front panel...........................................................................................................................8
5.2 Back panel............................................................................................................................ 8
6 Hardware Interface Description................................................................................................. 10
6.1 RS232 Control Interface................................................................................................... 10
6.2 Ethernet Interface............................................................................................................. 10
6.3 COM1-COM8(RS-232/422/485).................................................................................12
6.4 RS- 485 Bus........................................................................................................................ 12
6.5 Relay Ports......................................................................................................................... 12
6.6 IO input/output Ports....................................................................................................... 13
6.7 Infrared Output Port......................................................................................................... 13

5/13
1 Product Description
This professional distributed network programmable controller supports abundant control
interfaces and uses international standard communication interfaces to meet the control
requirements of various audio and video and peripheral equipment. The host adopts
industrial-level processing chips to ensure the high efficiency of all kinds of control and the
stability of the system.
2 Features
■Support Android and iOS Mobile phones or tablets
■8 independent programmable infrared transmission interfaces, support controlling many sets
of the same or different infrared equipments.
■8 independent programmable RS-232/422/485 control interfaces, user programmable
Multiple control protocols and codes.
■2 independent programmable RS-232 control interfaces, user programmable Multiple control
protocols and codes.
■8 weak relay interfaces.
■8 digital input / output IO interfaces which supports ADC/DAC conversion
■1 independent programmable CAN interface supports bidirectional communication.
■1 independent programmable RS-485 interface supports bidirectional communication.
■Embedded infrared learning device, convenient debugging and maintenance.
■Support local and remote control.
■The built-in WEB configuration interface of the central control host can facilitate the
configuration of basic parameters and improve the application efficiency of field engineers.
■The international general wide voltage (AC100 - 240V), can be wildly applied in any countries
and regions.

6/13
3 Typical Application

7/13
4 Specifications
Model
VS-C200
RAM
32M DDR-RAM,512M FLASH
FLASH
EEPROM: 4K, SPI FLASH: 4M
ETHERNET(TCP/IP)
1
Infrared emission
8
Digital I/O
8
Relay
8
RS-232/422/485 BUS
8
RS-485 BUS
1
CAN BUS
1
RS-232 BUS
2
Ground
YES
Maximum power dissipation
15W
Power supply
AC 110~240V
Dimensions(WxDxH)
1U(440mmx263mmx44mm)
Weight
About 4.6KG

8/13
5 Hardware Description
5.1 Front panel
(1) LCD:display real-time control status。
(2) Power—Power Indicator:this light is on when power supply normally。
Status—Status Indicator:this light is flashing when processing instructions。
IR—IR Receiving Window:Programmable Ethernet Controller provided built-in IR Learning
Module, and SENSOR can receiving the IR Signal to be learned for controlling。
(3) Digital key 0 ~ 9。
(4) Functional key。See brief description below:
AV
Switch button, separate input and output
channel for switch control
All
Switch to all output channel
Save
Save current scene,used along with digital
button
Load
Load scene saved before,used along with
digital button
Cancel
Cancel current operation
Enter
Confirm current operation
5.2 Back panel
(1) Eight COM ports, each port supports RS-232/422/485 bus standard
(2) One CAN bus control interface
(3) Eight programmable Low-current Relay Ports with NO (normal open) and NC (normal close)
(4) Eight programmable I/O ports: 5V/10mA output or 0~5V/10mA input

9/13
(5) Two RS-232 ports
(6) One RS-485 with 4-pin phoenix connector
(7) Eight Infrared Output Ports
(8) Hardware reset button
(9) Ethernet Interface
(10) Power supply: AC 110~240V

10 /13
6 Hardware Interface Description
6.1 RS232 Control Interface
One RS-232 input interface, which can be used to control the VS-C200 by using computer or
other control devices. It also has another RS-232 output port, designed to retransfer command
order to other peripherals. The Pin description is as follows:
■RS232 IN PIN description:■RS232 OUT PIN description:
■RS232 Connection
Link the VS-C200 to host control computer by using RS-232 cable, when connection is finished,
you can control the VS-C200 with the instructions we provided.
6.2 Ethernet Interface
■Cross-wire connection
Directly connect the VS-C200 to host computer by using Cat5/5e cross-wire.
Pin
Signal
Description
1
-
-
2
-
-
3
RXD
RS-232 protocol,receive data
4
TXD
RS-232 protocol,send data
5
GND
Signal ground
6
-
-
7
-
-
8
-
-
9
-
-
Pin
Signal
Description
1
-
-
2
TXD
RS-232 protocol,send data
3
RXD
RS-232 protocol,receive data
4
-
-
5
GND
Signal ground
6
-
-
7
-
-
8
-
-
9
-
-
Tabla de contenidos