Cleveland Convotherm PC-Control Manual de usuario

260AZV REV. B 7-06
Operating Instructions
CONVOTHERM PC-Control
CONVOTHERM PC-HACCP
1333 East 179th Street
Cleveland, Ohio 44110
Phone: (216) 481-4900
1-800-338-2204
Fax: (216) 481-3782
www.clevelandrange.com

Operator's Manual
CONVOTHERM PC-HACCP TABLE OF CONTENTS
10 July 2006
Table of Contents
CONVOTHERM PC-HACCP and PC-Control
1. Introduction
1.1 General Information for CONVOTHERM PC-HACCP AND PC-CONTROL
1.2 System Requirements
2. CONVOTHERM PC-HACCP
2.1 Installing, Setting Up and Starting the software
2.1.1 Installing the CONVOTHERM HACCP Software on a PC
2.1.2 Setting Up the CONVOTHERM PC-HACCP Software
2.1.3 Setting the Network Address on the Combi Ovens
2.1.4 Log On and Off Combis in CONVOTHERM PC-HACCP
2.2 Automatic Storage of the Combi’s HACCP Data
2.2.1 Starting Automatic HACCP Documentation
2.2.2 Backing Up HACCP Data
2.3 Assigning HACCP Criteria to Programs (Recipes)
2.4 Making HACCP Criteria Is Fulfilled
2.4.1 Online Check
2.4.2 Checking HACCP Criteria
3. CONVOTHERM PC-Control
3.1 Software Installation, Setup, and Startup
3.2 Create a Cookbook on the PC
3.2.1 Multi-Step Programming
3.2.2 Modify an Existing Program
3.2.3 Additional Functions
3.2.4 Delta-T Cooking, Cook&Hold
3.3 Managing Recipes
3.3.1 Saving the Cookbook
3.3.2 Saving the Cookbook Under a Different Name
3.3.3 Displaying Different Program Lists
3.3.4 Print Lists
3.3.5 Sort Lists
3.3.6 Copy, Cut, Paste, or Delete a Program
3.4 Using the Cookbook
3.4.1 Sending Programs to a Combi
3.5 Other Functions
3.5.1 Changing the Pre-programmed Values in the PC-Control program
3.5.2 Disable or Enable Controls on a Combi
3.5.3 Send a Cookbook by e-Mail

Operator's Manual Page 1
1. INTRODUCTION
10 July 2006 Introduction
1.1 General Information for CONVOTHERM PC-HACCP and
CONVOTHERM PC-CONTROL
CONVOTHERM PC-HACCP and CONVOTHERM PC-CONTROL
•The PC uses the PC-HACCP software to communicate with the Combi or Combis.
•The PC-HACCP software must be started on the PC before the PC-Control software
can work.
CONVOTHERM PC-HACCP
•The Convotherm PC-HACCP software automatically records all processes run on
Convotherm Combis and stores them for HACCP monitoring.
•After cooking, the HACCP data is stored and can be graphed for review.
CONVOTHERM PC-CONTROL
•The Convotherm PC-Control software can store up to 250 recipes. The recipes can be
transferred to all your networked Combis in seconds.
•Recipes can be deleted, copied, or changed as needed.
•Stored recipes and functions including Cook & Hold, Delta-T Cooking, reduced fan
speed, reduced power, Crisp ‘n’ Tasty, and security can be programmed with HACCP
criteria and monitored with the Convotherm PC-HACCP software.
1.2 System Requirements
Hardware
Convotherm oven single installation:
All Combi models require ST 5000 V2.20 software.
Convotherm oven network installation:
All Combi models require ST 5000 V2.20 software.
All Combi models require a Communication Module Kit.
Computer Hardware:
•IBM compatible PC with a 486 MHz or faster processor.
•RS232/V24 serial port.
•Windows 95 or higher.
•CD-ROM drive.
•10 MB free storage on the hard drive.

Operating Instructions
2. CONVOTHERM PC-HACCP
page 1
10 July 2006 CONVOTHERM PC-HACCP
2.1 Installing, Setting Up and Starting the Software
1. Install the CONVOTHERM PC-HACCP software and set it up to suit your hardware.
2. This software can manage two "networks" of one Combi each as a stand-alone system
or up to 31 Combis each as a network installation.
3. For each of the networks used, the interface (COM) port must be selected.
4. In the selected (see below) network, each Combi used for recording HACCP data or for
transferring Programs must be logged in.
2.1.1 Installing CONVOTHERM HACCP Software on a PC
1. Start Windows 95 or Windows NT on the PC.
2. End all other programs before installing the Convotherm software.
3. Insert the installation CD-ROM into the CD-ROM drive.
4. Use Windows Explorer to navigate to the CD-ROM drive.
5. Open the SETUP.EXE installation program.
6. Follow the instructions in the installation program.
•The required directories are created automatically.
7. When installation is complete, start the program in Explorer by clicking on
CONVOTHERM-HACCP.EXE in the selected directory.
•If there is an error beep when the program starts, correct the network interface,
and see 2.1.2.
8. In the window Responsible chef, in the field new, enter the name of the person
responsible for the HACCP documentation.
9. Click add.
10. Click OK to save or Cancel to quit without saving.

Operating Instructions
2. CONVOTHERM PC-HACCP
page 2
10 July 2006 CONVOTHERM PC-HACCP
2.1.2 Setting Up the CONVOTHERM PC-HACCP Software
Network Settings
1. Start the CONVOTHERM PC-HACCP software.
2. In the Setup menu, go to Options.
3. In Network 1, choose a COM port.
•Most computers use COM1 for RS232.
•The USB network COM selection will depend on the software included with the
USB/Network adapter.
4. In Network 2, choose a second COM port even if the second network will not be used.
5. Click the connection type:
•RS232/V24 for a stand-alone system.
•RS485-Network for a network system.
6. Click OK to save or Cancel to quit without saving.
7. Close the program and restart it.

Operating Instructions
2. CONVOTHERM PC-HACCP
page 3
10 July 2006 CONVOTHERM PC-HACCP
Select Temperature in ºC or ºF
1. In the CONVOTHERM-HACCP window, click Options.
2. Click Measurement unit.
3. Click °C or °F.
4. Click OK to confirm or Cancel to quit without making changes.
2.1.3 Setting the Network Address on the Combi Ovens
•Address 1 is factory set on all Combis.
•To connect more Combis to the PC, the Addresses must be changed to 2, 3, 4, etc.
•No change is needed to work with only one Combi.
On the Combi Control Panel:
1. Press the Smart Key.
2. Scroll to the Setup icon (it looks like an oven).
3. Press the Smart Key for YES.
4. Scroll to the Network Address icon (it looks like three computers tied together).
5. Enter the address of the Combi.
•The first Combi is 1, the second Combi is 2, etc.
6. Press the Stop key to end the program.
7. Switch the Combi OFF and then back ON.
2.1.4 Log On and Off Combis in CONVOTHERM PC-HACCP
•All Combis connected to the PC must be logged on to the CONVOTHERM PC-HACCP
software.
•Each Combi needs an individual network address (number) and a name.
•When the Combis are logged on, they are displayed on the screen with a symbol and a
name and change to a light color.
•The network address assigned during log on must match the address set on the Combi.
(Continued on next page.)

Operating Instructions
2. CONVOTHERM PC-HACCP
page 4
10 July 2006 CONVOTHERM PC-HACCP
1. Click on the Options menu.
2. Click on Combi Steamer.
3. Click on Connect.
4. Select the Network Address (N1:, N2:, etc.) of the Combi in the Address scroll window.
5. Enter a Unit name:, (“First oven” shown).
6. In connected with:, click Network 1, or Network 2.
7. Click the connect button. An “x” appears next to theAddress of the Combi.
8. Click OK to confirm or Cancel to quit without making any changes.
(Continued on next page.)

Operating Instructions
2. CONVOTHERM PC-HACCP
page 5
10 July 2006 CONVOTHERM PC-HACCP
9. The Combi icon is displayed with its unit name. (“First o…” shown.)
10. When a Combi is connected with the software, its icon changes from dark grey to a light
color to confirm the connection.

Operating Instructions
2. CONVOTHERM PC-HACCP
page 6
10 July 2006 CONVOTHERM PC-HACCP
2.2 Automatic Storage of the Combi’s HACCP Data
2.2.1 Starting Automatic HACCP Documentation
Automatic HACCP Documentation:
1. Start the CONVOTHERM PC-HACCP software.
2. Name the Responsible Chef.
3. Every cooking process is recorded for each Combi logged on, and stored in a Daily File
titled (day_month_year.HCP). (“18_10_05.HCP” shown.)
4. As soon as a Program is finished, it is automatically stored.
•Brief cooking periods can be excluded from storage by using a Time Filter.
Time Filter:
Note: Any cooking processes that are shorter than the value entered in the Time Filter is
not stored. This information is lost!
1. Click on Options.
2. Click on Time filter.
3. Enter a value or change the value with the arrow keys.
•Enter 0 min to record every cooking process.
4. Choose OK to confirm or Cancel to quit without making any changes.
2.2.2 Backing Up HACCP Data
Make a backup of your HACCP data.

Operating Instructions
2. CONVOTHERM PC-HACCP
page 7
10 July 2006 CONVOTHERM PC-HACCP
2.3 Assigning HACCP Criteria to Programs (Recipes)
•Each Combi can store up to 250 Programs (recipes).
•CONVOTHERM PC-HACCP software can manage only 250 Programs with up to
9 steps in each.
•The same recipes must match the same number in all the networked Combis. (For
example, "grill chicken" is Program number 5 in all the networked Combis).
•Different Programs can be stored in networked Combis.
•Do not use the same number for different Programs. Instead, use the same number for the
same Program in ALL the networked Combis for a maximum of 250 Program numbers.
•In the CONVOTHERM PC-HACCP software, HACCP criteria can be allocated using
these Program numbers.
•These criteria are used to check every Program when it is started on a Combi.
1. Start the CONVOTHERM PC-HACCP software.
2. Click Program.
3. Click Program list.
NOTE: Steps 4 and 5 are not necessary if the Program was created using PC-Control
and a name is already allocated. If so, go to Step 6.
4. Select the Program number (Prog. No.) in the list on the left.
5. Enter the Program name.
6. Enter the HACCP criteria:
•CTC ÆTemp and time
•cooking temp ÆTemp and time
7. Click OK to save or Cancel to quit without saving.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Controladores de Cleveland