ClearSound CL2L Manual de usuario

CL2L
Telephone rin
g
er amplifier with flasher and
door bell
Indicateur d’appel téléphonique avec flash
et sonnette
Telefonklingelverstärker mit
Blitz und Türklingel
English Page 2
Français Page 15
Deutsch Page 28

CAUTION: The switch for Ringer ALARM
selection must never be set during ringing/
flashing mode but always when CL2 is silent
mode ( No incoming call ringing).
ATTENTION: Le commutateur de configuration
du mode Alarme ne doit jamais être changé
lorsque le CL2 envoie sa sonnerie (ou flash
lumineux ) mais uniquement durant le mode
repos.
WARNUNG: Bitte die Taste für die Auswahl
des Klingeltons niemals während des Läutens
bzw. Blitz-Signals betätigen, sondern nur im
Ruhe-Modus ( kein eingehender Anruf ).
1

DESCRIPTION
1. DESCRIPTION
The CL2 will alert you to both doorbell and telephone. It
has adjustable volume and different tone settings for
doorbell and telephone.
2
(*) Classified TNV-3 according to EN60950 standard.
Door bell
LED
4 ringer
settings
Volume
control
Doorbell Tone
control
Phone ringer
amplifier tone
control
Strobe flasher Loud sound
alarm
FRONT VIEW
REAR VIEW
BELL PUSH
Bell push
button
Wall mountin
Pairin
g
/Test Button
g
holes
Telephone line
cord socket
(
*
)
Modular jack for
tele
p
hone line cord
(
*
)
Mains power lead socket (*)
Shaker socket (*)

INSTALLATION
2. INSTALLATION
3
230V
AC/DC
dt
Double plug
Wall socket
Telephone
Option :
to link
two CL2s
Screw wall mount
Door Bell
Button
Door Bell
Special cable
Option : Shaker
(ref.: SHAKCL_BLK only)
1 - Connect the CL2 line cord in CL2 “Line IN”.
2 - Connect your Telephone in the double plug of the line
cord.
3 - Connect the double plug in the Telephone wall socket.
4 - If necessary connect the required shaker
(SHAKCL_BLK only) to the shaker plug input.
5 - Connect the mains adaptor line cord in CL2 12V DC
input.
6 - Connect the mains adaptor in the 230V wall socket.
(*)

INSTALLATION
(*) Classified "hazardous voltage" according to EN60950
standard.
Electrical connection: The apparatus is designed to
operate from a 230V 50Hz supply only. (Classified as
'hazardous voltage" according to EN60950 standard).
The apparatus does not incorporate an integral power
on/off switch. To disconnect the power, either switch off
supply at the mains power socket or unplug the AC
adaptor. When installing the apparatus, ensure that the
mains power socket is readily accessible.
Telephone connection: Voltages present on the
telecommunication network are classified TNV-3
(Telecommunication Network Voltage) according to the
EN60950 standard.
4

BELL PUSH WALLMOUNTING
3.1. BELL PUSH – WALL MOUNTING
5
The wire free bell push is mounted by the front door. It
has a range of 20-60 metres depending on the structure
of the building (see note).
Test the system before mounting
on the wall – plug in the CL2 and
press the bell push button to
check that the CL2 rings.
To mount the bell push, open
the access cover in the middle of
the bell push with a needle or
small screwdriver.
Decide where to position the bell
push and use the wall mount
template, shown below, to mark
the holes on the wall or door
surround and drill holes if
necessary.
Align with prepared marks or screwholes, insert and
tighten screws and replace access cover.
Bell push is now ready for use.
Note: Do not place the bell push onto a metallic base or
near electric equipment (such as TV, Radio, computer,
washing machine...). The CL2 will work within a range of
60m in an environment where there are no obstacles
and 20m in an environment which contains a wall or
metallic structure.

WALL MOUNTING BELL PUSH
WALL MOUNTING TEMPLATES
To wall mount the bell push or the CL2, use these
templates to mark the screw hole centres. We
recommend the use of a spirit level to ensure the holes
are level.
CL2 template
Bell push template
6

BELL PUSH CHANGE THE BATTERY
3.2. CHANGE THE BATTERY
The door bell is supplied with a 23A 12V battery. The
CL2 is supplied ready to use, it is not necessary to open
the bell push when you first install the CL2.
To replace the battery, open the access cover and
unscrew the door bell from the wall, unscrew the three
screws located on the base and open the box to get
access to the battery compartment. Replace the battery,
replace back and remount.
Back of Bell Push Inside Bell Push
Unscrew to
open
Battery
Switches for
LED colour
Note: Do not use a rechargeable battery. Do not put the
used battery into the household rubbish, pay attention to
battery regulations regarding battery disposal.
7

CL2 SETTINGS
4.1. CL2 SETTINGS
ALARM MODE SETTING
For incoming calls – choose
which alarm mode you want by
moving the alarm mode switch
to one of the following positions:
No alarm selected
Doorbell/ringer
amplifier and strobe
flasher Flasher:
Bell push – 3-4 flashes
Telephone – flashes as
long as phone rings
Doorbell, strobe
flasher and shaker
(if connected)
Doorbell/ringer amplifier and shaker
(if connected)
VOLUME CONTROL
For doorbell and ringer amplifier:
Use the slider control to adjust
the volume of the sound alarm
of the CL2.
8
Tabla de contenidos