3
USER MANUAL – ENG
Important
For your own safety please read and remember the following instructions be-
fore use. If you have any questions, please contact the manufacturer or your
distributor. Keep the manual for future reference.
1. Introduction
CleanAIR®is a personal respiratory protection system based on the principle
with long-term use. Breathing remains easy because the user does not have to
Pressure Flow Master system, which operates on the principle of supplying air
from locations with clean air.
All the light hoods presented in this user manual provide respiratory protection
and face protection against particles with high speed and low energy impact.
the manufacturer or your supplier!
2. Limitations on use
1. Never use the hood in the following environments and under the following
conditions:
• If oxygen concentration in the environment is lower than 17 %.
• In oxygen-enriched environments.
• -
gerous substances and their concentration.
• In environments that represent an immediate danger to life and health.
2. If the protection foil is damaged, replace it immediately.
3.
substances.
4.
following problems occur while using the hood:
• -
lems with breathing.
• If you experience stench, irritation or an unpleasant taste while breathing.
• If you feel unwell or experience nausea.
5. -
-
plied air from the respirator.
6.
protect the user against any gases. Filters designed for capturing gases do
7.
8.
system is damaged.
9.
10.
3. Cleaning and maintenance
daily basis of possible damage of its inside or outside the structure. Careful use
and correct maintenance of the protective hood enhances operating life and
improves your safety!
Checking before use:
Inspect that every part of the hood is undamaged and installed correctly.
Cleaning:
•
replace damaged parts.
•
of harmful contaminants settled on individual parts!
• -
gent, and a soft brush (It is not recommended to use other cleaning agents
• After cleaning individual parts with a damp cloth, it is necessary to rub them
dry or let them dry at room temperature.
• For care about the visors and plastic parts is recommended to use the Clea-
nAIR®®
It is necessary to pay more attention to the protection of the product
when using a washing machine or a dishwasher!
When cleaning with acetone or other solvents the product may get
damaged and may lose protection.
Visor protective foils
Hoods are supplied with a foil protecting the visor against damage during han-
provided with self-adhesive tapes on the sides.
Protective foil replacement:
•
impurities from it.
•
on the shield.
Headband adjustments
1.
position of the headgear is where the sweatband sits slightly above the level
of the eyebrows.
2.
• VariGEAR: by turning the rear wheel.
• Basic headgear: resetting the front headband.
3. Set the optimal distance between the nose and visor to 2 cm. Reset the
position of the rails on both sides of the headgear (see the pictorial annex
4. Materials
Part Product Material
Hood CA-1 lite, CA-2 lite Microporous polypropylene
CA-1, CA-2 Nylon
CA-10, CA-10G Polyethylene laminated
Visor CA-1 lite, CA-2 lite
CA-1, CA-2, CA-10,
CA-10G
Cellulose propionate
5. Storage and shelf life
Store the hood in a dry and clean place at room temperature, avoid direct sun-
6. Warranty
-
ufacturing or material defects that appear within 12 months of the date of purchase.
made.
7. List of products and spare parts
Product code Product description
720101 Short protective hood CA-1 lite
720201 Long protective hood CA-2 lite
720102B Short protective hood CA-1, blue
720102 Short protective hood CA-1, orange
720112 Short protective hood CA-1+, orange
720112B Short protective hood CA-1+, blue
720202B Long protective hood CA-2, blue
720202 Long protective hood CA-2, orange
721002 Chem-proof protective hood CA-10
721002G Chem-proof protective hood CA-10G