Clean Logix ALX-ELITE Manual de usuario

USER
MANUAL
English (Original Instrucons)
Updated: 04/03/17
MODEL:
ALX-ELITE
Chemical Allocaon Controller

Page 2 of 28 ALX-ELITE Manual V1.1 Last Update: 04/03/2017
USER MANUAL: ALX-ELITE
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Table of Contents
General
Overview
Terminology
Specicaons
Installaon
Installaon Requirements
Mounng Controller
Connecng Ethernet
Connecng Devices
Conguraon
Administrator Login
Users
Devices
Applicaons
Permissions
Conguraon (connued)
Unit Conguraon
Unit Info
Set Date & Time
USB Opons
Network Setup
Reporng
Operaon
Dispensing An Applicaon
Retrieving Reports on USB
Troubleshoong
Appendices
System Editor
Parts Callout
Device Calibraons
03
03
03
04
05
05
05
08
08
10
14
16
17
17
17
18
19
20
22
23
24
26
28
29
!
WARNING:
1. Avoid contact of chemicals with skin and eyes. If contact
occurs, see MSDS sheet for further rst aid measures.
2. Always wear appropriate PPE
3. Follow safety instrucons of chemical manufacturer
(MSDS).
4. Always follow plant and OSHA guidelines about the use
of equipment.
5. Disconnect power before servicing equipment.

Page 3 of 28 ALX-ELITE Manual V1.1 Last Update: 04/03/2017
USER MANUAL: ALX-ELITE
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
GeneralInstallaonConguraonAppendices Operaon
Troubleshoong General
The ALX-ELITE is a chemical management
controller that can dispense chemicals according
to programmable recipes (Applicaons). Access to
Applicaons can be restricted on a per-user basis over
a rolling me period. Users can be required to use
a 4-digit login passcode or RFID card to login before
dispensing Applicaons. This allows tracking and
recording of chemical usage by User. The ALX-ELITE
will generate and e-mail Reports on demand or on
a daily, weekly or monthly basis. Reports can also
be downloaded to a USB ash drive for immediate
viewing. All conguraon of the ALX-ELITE can be
performed using the built-in keypad and character
display. The ALX-ELITE will also broadcast a local WiFi
network which allows access to the web-browser
based System Editor for conguraon using a laptop.
Overview
Soware
• Maximum number of Users: 999
• Maximum number of Applicaons: 999
• Maximum Dispense Steps per Applicaon: 6
• Dispense Step me range: 00.1s - 99m:99.9s
• Permissions me range: 1-24 hours
• Max Permissions count: 99
Hardware
• Maximum number of Devices: 16*
• Dimensions: 12" x 10" x 7"
*NOTE: A single CAN-SO-4 counts as 4 Devices
Acceptable Chemical Products
• Acids
• Causcs
• Sanizers
• Chlorine
Specicaons
Terminology
• Users - The people who will be using the system
to dispense Applicaons. Up to 999 users can be
stored.
• Permissions - Control the number of mes
each User can access each Applicaon. Can be
disabled.
• Devices - The physical outputs and/or inputs that
connect to the controller to perform a funcon.
The ALX-ELITE is compable CAN-SO-1 and CAN-
SO-4 solenoid valve output devices.
• Applicaons - Recipes which determine the type
and sequence of Dispense Steps. Up to 999
recipes can be stored.
• Dispense Steps - Segments of an Applicaon that
determine which output Device will be energized
and for how long. Each Applicaon can contain up
to 6 Steps.
• Fixed Time Step - Will energize an output Device
for a specied amount of me. Reported Step
volume must be manually entered.
• Calibrated Step - Uses Device Calibraon to
determine how long an output Device should be
energized, based on a specied target volume.

Page 4 of 28 ALX-ELITE Manual V1.1 Last Update: 04/03/2017
USER MANUAL: ALX-ELITE
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Electrical
• 110 VAC, 5A, Single Phase, 50-60 Hz
• NEMA 5-15 GFCI Protected Outlet
• Surge suppression recommended
Network
• Cat 5e or higher Ethernet cable connecon (eld-
wired sealed plug included with unit)
-OR-
• WiFi (802.11n or 802.11b/g), WPA security
Compressed Air (typical installaon)
• Clean, dry air
• 10 CFM (283 L/min) @ 80 psi (5.5 bar) minimum
• 100 psi (6.9 bar) maximum supply pressure
• Recommended regulator seng: 80 PSI (5.5 bar).
Water Supply (typical installaon)
• Cold Portable Water
• 7 GPM (26.5 Lpm) @ 35 psi (2.5 bar) minimum
• 100 psi (6.9 bar) maximum supply pressure
• Recommended regulator seng: 50 PSI (3.4 bar).
NOTE: A back ow preventer must be installed in the
water supply to this unit, per local codes.
Installaon Requirements

Page 5 of 28 ALX-ELITE Manual V1.1 Last Update: 04/03/2017
USER MANUAL: ALX-ELITE
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
GeneralInstallaonConguraonAppendices Operaon
Troubleshoong Installaon
AIR OUTPUTS
(3/8" PUSH-FIT)
AIR INLET 2
(3/8" PUSH-FIT)
AIR INLET 1
(3/8" PUSH-FIT)
CONNECT TO
OTHER CAN
DEVICE
CAN-SO-4
AIR OUTPUT
(3/8" PUSH-FIT)
CONNECT TO
OTHER CAN DEVICE
CONNECT TO ALX
CONTROLLER OR
OTHER CAN DEVICE
AIR INLET (3/8"
PUSH-FIT)
CAN-SO-1
1. Determine mounng locaon, with consideraon
of the following:
• User accessibility
• Distance to electrical outlet
• Distance to Devices/pumps
• Accessibility to Ethernet or WiFi
2. Aach the included mounng feet to the
controller.
3. Securely mount unit to wall using appropriate
hardware (not included).
Mounng
Hole
Dimensions
4. Plug power cord into a 115 VAC, GFCI protected
receptacle.
Mounng Controller
1. Connect ethernet using supplied plug. Following
instrucons included with plug.
NOTE: This plug must be used to ensure
environmental sealing of the ethernet port!
Connecng Ethernet (if not using WiFi)
The following types of Devices are compable with
the ALX-ELITE:
• CAN-SO-4: A four output, 3-way solenoid valve
pack for controlling 1/2" or smaller AODD pumps
and/or air operated valves
• CAN-SO-1: A single output, 2-way solenoid valve
for controlling up to a 1" Air Operated Double
Diaphragm (AODD) pumps
Connued on next page
Connecng Devices

Page 6 of 28 ALX-ELITE Manual V1.1 Last Update: 04/03/2017
USER MANUAL: ALX-ELITE
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
1. Mount and connect Devices in a daisy-chain fashion using the orange M12 cables. They can be installed in
any order. (NOTE: If purchased as a -KIT, the Devices will be supplied pre-mounted and connected)
2. Hand ghten M12 cable connecons, then ghten two more clicks using wrenches.
3. Plumb compressed air lines and uid lines for pumps and valves as necessary [see below]
Connecng Devices (connued)
Installaon Example

Page 7 of 28 ALX-ELITE Manual V1.1 Last Update: 04/03/2017
USER MANUAL: ALX-ELITE
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
GeneralInstallaonConguraonAppendices Operaon
Troubleshoong Installaon
Notes:

Page 8 of 28 ALX-ELITE Manual V1.1 Last Update: 04/03/2017
USER MANUAL: ALX-ELITE
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
ELITE Admin Menu
1-Users
2-Devices
3-Applications
4-Permissions
5-Unit Cong
6-Unit Info
7-Set Date & Time
8-USB Options
9-Network Setup
10-Reporting
Edit Users
>00-Add New User
01-administrator
Editing User #02
Name:Jason
Password: 1234
Admin: >NO< YES
RFID: 0000000000
Edit Permissions
(DELETE Entry)
Save changes?
Are you SURE?
Press <= for Yes
Press => for No
1. Press the ADMIN key.
2. Type in a 4-digit administrator passcode.
NOTE: The default Administrator user
passcode is 1234. This passcode can be
changed under the “Users” secon.
NOTE: Users will be automacally logged out
aer 1 minute of inacvity for security.
Administrator Login
Users
Adding a User
1. Log in as an administrator.
2. Use ↑and ↓keys to select Users and press
ENTER.
3. Select 00-Add New User and press ENTER.
4. Enter a Name and a 4-digit Passcode.
NOTE: Each user must have a unique 4-digit
passcode.
5. Use →and ← keys to grant or deny Administrator
privileges.
6. If desired, an RFID card can be scanned to
populate the RFID eld.
NOTE: Only one RFID card can be assigned per
user, cards cannot be shared between other
users.
7. Press the ESC key to exit.
8. When prompted to save changes, press ←for Yes
or →for No.
!
This secon explains how to setup the ALX-ELITE using the built-in keypad and screen. Alternavely, a
laptop or tablet can be used. For more informaon, refer to Appendix A - System Editor.

Page 9 of 28 ALX-ELITE Manual V1.1 Last Update: 04/03/2017
USER MANUAL: ALX-ELITE
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
GeneralInstallaonConguraonAppendices Operaon
Troubleshoong Conguraon
Edit Users
00-Add New User
01-administrator
>02-Jason
Delete this User?
Are you SURE?
Press <= for Yes
Press => for No
Editing User #02
Name:Jason
Password: 1234
Admin: >NO< YES
RFID: 0000000000
Edit Permissions
(DELETE Entry)
!
CAUTION:
The unit will always require at least one user to be
an administrator. Be careful not to delete all of the
administrators!
Eding a User
1. Select a user in the list and press ENTER.
2. Edit the user sengs as necessary
3. Press the ESC key to exit.
4. When prompted to save changes, press ←for Yes
or →for No.
Deleng a User
1. Select a user in the list and press ENTER.
2. Use the ↓ key to scroll to the boom of the
screen.
3. Select (DELETE Entry) and press ENTER.
4. When asked to conrm, press ←for Yes or →for
No.
Users (connued)

Page 10 of 28 ALX-ELITE Manual V1.1 Last Update: 04/03/2017
USER MANUAL: ALX-ELITE
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Edit Devices
>0555-CONFIG PUMP
0875-CONFIG PUMP
0689-Water (Red)
Editing Device #0555
Demo Chemical
Type: AODD Pump
Prime (Start/Stop)
Edit Calibration
Replace Controller
(DELETE Entry)
Editing Device #0555
Demo Chemical
Type: Piston Pump
Prime (Start/Stop)
Volume: 000.00oz
ON Time: 00.0s
OFF Time: 00.0s
Replace Controller
(DELETE Entry)
Save changes?
Are you SURE?
Press <= for Yes
Press => for No
Adding a Device
1. Make sure devices are connected and green lights
are illuminated.
2. Log in as an administrator.
3. Use ↑and ↓keys to select Devices and press
ENTER.
4. Select a device from the list and press ENTER.
NOTE: When new Devices are rst connected,
they will appear in the Device list with the
name "CONFIG PUMP"
TIP: A red indicang light will blink on the
currently selected device
5. Type in a name for the device
6. Select the Device Type:
• AODD Pump - Constant output
• Valve - Constant output
• Piston Pump - Pulsed output with user
dened stroke Volume and ON/OFF cycle
Time.
7. If Piston Pump is selected, enter stroke volume
and ON/OFF Time
8. If you wish to prime, press the START key to turn
the Device output on and press STOP when to
turn o.
!
WARNING:
Pressing the START key on this screen will cause
the output to turn on and the pump to run!
Wear PPE and be ready to contain the ow of
chemical in an appropriate vessel!
9. Press the ESC key to exit.
10. When prompted to save changes, press ←for Yes
or →for No.
Devices
Tabla de contenidos
Otros manuales de Controladores de Clean Logix