Clarinet Systems EtherUSB Manual de usuario

User Manual
EtherUSB™
USB Ethernet Access Point for PDA
V 2.0
Clarinet Systems, Inc.
Clarinet Systems, Inc. http://www.clarinetsys.com Page 1

Publication Revision No. Control Table
Rev. No. Date Contents
2.0 05/14/2008
1. Removed Information that no longer apply.
2. Updated copyright information.
3. Updated the EtherUSB AdminTool to reflect latest
changes.
4. Updated EA104 pictures.
1.9 03/18/2008 Support multiple WM 6.0 devices.
1.6 08/22/2007 Support connection of multiple WM5.0 devices
1.5 06/18/2007 Support four Ethernet ports
1.0 01/16/2007
Copyright
Copyright 2006 - 2008 Clarinet Systems, Inc. All rights reserved. Information in this
document is subject to change without notice. No part of this publication may be
transmitted, transcribed, reproduced, stored in any retrieval system or translated into
any language or computer language in any form or by any means, mechanical,
electronic, optical, chemical, manual or otherwise, without the prior written permission of
Clarinet Systems, Inc., 48834 Kato Rd. Suite 101A, Fremont, CA 94538
Clarinet Systems and EtherUSB are trademarks of Clarinet Systems, Inc.
All other company and product names are trademarks or registered trademarks of their
respective owners.
Clarinet Systems, Inc. http://www.clarinetsys.com Page 2

Table of Contents
1PRODUCT OVERVIEW...............................................................................................................................................................4
2HARDWARE INSTALLATION ....................................................................................................................................................6
2.1 STATUS LED, PORT, AND BUTTON OF EA104 MAIN UNIT...................................................................................................................6
2.1.1 External Status LED ...............................................................................................................................................................6
2.1.2 Ports .......................................................................................................................................................................................6
2.2 HARDWARE INSTALLATION...............................................................................................................................................................7
3CONFIGURATION.......................................................................................................................................................................8
3.1 PDA SUPPORT................................................................................................................................................................................8
3.2 ETHERUSB WEB-BASED ADMINISTRATION TOOL (ADMINTOOL).........................................................................................................8
3.3 ACCESS ADMINTOOL AND CHANGE EA104 INITIAL VALUES................................................................................................................8
4SPECIFICATIONS AND PROVISIONS.......................................................................................................................................9
4.1 DIMENSIONS ...................................................................................................................................................................................9
4.2 ENVIRONMENT SPECIFICATIONS.......................................................................................................................................................9
4.3 AC ADAPTER SPECIFICATIONS.........................................................................................................................................................9
4.4 SAFETY AND EMI CERTIFICATE ........................................................................................................................................................9
5FUNCTIONS AND COMPATIBILITY ........................................................................................................................................10
5.1 PROTOCOLS..................................................................................................................................................................................10
5.1.1 Communications protocols ..................................................................................................................................................10
5.1.2 Network protocols................................................................................................................................................................10
5.1.3 Network connection side......................................................................................................................................................10
5.1.4
PDA connection side..........................................................................................................................................................10
5.1.5 PDA Compatibility................................................................................................................................................................10
5.1.6 Communications Procedures................................................................................................................................................10
5.2 EA104 FIRMWARE VERSION .........................................................................................................................................................10
APPENDIX A – QUICK START GUIDE...............................................................................................................................................11
APPENDIX B – CE5.0, CE.NET 4.1/4.2, AND PPC 2003/2003SE PDA.............................................................................................15
B.1 INSTALLATION ON THE PDA...........................................................................................................................................................15
B.2 COMMUNICATIONS WITH THE SERVER............................................................................................................................................15
B.3 ACCESS INTERNET........................................................................................................................................................................15
Clarinet Systems, Inc. http://www.clarinetsys.com Page 3

1 PRODUCT OVERVIEW
The EtherUSB™EA104 is a USB Ethernet Access Point for connecting PDA and PDA
phone using Pocket PC 2003/2003SE operating systems (OS), CE5.0, CE.NET4.1/4.2
and Windows Mobile 5.0 and Windows Mobile 6.0 to an Ethernet network. Connection
is established using a PDA USB cradle or with USB cables via the PDA USB port
to10/100 Base-T Ethernet network. EA104 belongs to EtherUSB™ product line.
EA104 is equipped with 4 USB host ports and four 10/100 Base-T ports, one for uplink
to the Ethernet network and three for optional connection of PC or computing devices.
EA104 provides TCP/IP-based network connectivity for up to 4 PDA devices
simultaneously using a PDA USB cradle or USB cables and the server side 10/100
Base-T network.
To get started immediately, please refer to Appendix A – Quick Start Guide.
Each connected PDA can perform server synchronization, Internet browsing, and file
transfer. This solution provides an alternative network connection other than WiFi, while
offering higher security and reliability standards. It works perfectly for the mobile users,
Clarinet Systems, Inc. http://www.clarinetsys.com Page 4

field application personnel, and any environment that requires a high level of security
and reliability. 500mA power provided to each USB port enables recharging of PDAs
while connected.
Clarinet Systems, Inc. http://www.clarinetsys.com Page 5

2 HARDWARE INSTALLATION
Please confirm the following items have been included in the shipping box with the main
product.
1. EA104 main unit
2. 180cm (6’) Ethernet cable
3. 5VDC/3A power adapter, 2.1x5.5mm plug, center positive polarity
4. A paper notice that indicates the website from which to download the EA104
Users Manual (this manual), Data Sheet and about WM5.0 and WM6.0 device
connection.
2.1 Status LED, port, and button of EA104 main unit
2.1.1 External Status LED
Signal Name Status
Power Solid after power-on which indicates unit ready for operation
Slow blink during operation
Fast blink if power-on self test fails – bad unit
Ethernet Glows green indicates a link has been established with another device
Flashing indicates Ethernet activities from itself or others
USB Glows green if a USB connection has been made
Fast flashing - (Important: don’t unplug USB connector during this
period which lasts 4~40 seconds.)
2.1.2 Ports
1. Four Ethernet RJ45 and four USB female connectors.
2. One DC power connector.
3. One Reset button: press and hold the Reset Button for 8 seconds or longer, to
reset EA104 to factory default and then reboot.
Clarinet Systems, Inc. http://www.clarinetsys.com Page 6

2.2 Hardware Installation
1. Connect the Ethernet cable to the EA104 Ethernet uplink (WAN) and the other
end to Ethernet switch/hub*.
2. Connect PDA to the EA104 USB port**.
3. Connect the power adapter to rear socket of the EA104, then into the wall outlet.
If power is present, the EA104 will proceed with normal power on sequence - self
test and boot up sequence within 25 seconds; once the Power LED is solid in
color on the front panel, the unit is ready.
• If the unit has a problem, the power LED will flash quickly.
• If the network connection has a Link, the Ethernet LED will blink green.
• If USB devices are connected & recognized by the EA104, the
corresponding LED will illuminate on the front panel.
To shut down the EA104, disconnect the AC power adapter. Do not shut down the
EA104 when there is a PDA performing data communications since this may
cause data to be lost.
Notes:
* In a non-DHCP environment, the system administrator must set up an enclosed
DHCP network by accessing the EA104 configuration using the browser-based
AdminTool.
Clarinet Systems, Inc. http://www.clarinetsys.com Page 7

3 CONFIGURATION
3.1 PDA support
The EA104 currently supports PDAs running PPC 2003, CE/Net 4.1 & 4.2, CE5.0 and
Windows Mobile 5.0 and 6.0.
3.2 EtherUSB web-based Administration Tool (AdminTool)
The EtherUSB web-based AdminTool can be accessed via Internet Explorer browsers.
This tool provides the following functions:
• Use static IP or DHCP for EtherUSB
• Setup IP address, Subnet Mask, Gateway, WINS and DNS information when
using static IP.
• Setup network identification such as device name and domain name for the
EtherUSB
• Change password
• Review reports of critical changes
• Update firmware
3.3 Access AdminTool and change EA104 initial values
Please refer to EtherUSB Admin Tool User Manual for information on access and
modify EA104 configuration.
Factory default can be restored by pushing the Reset Button for 8 seconds or longer.
The Default Factory Setting is as follow:
Device Name: <Serial Number>
Domain Name:
IP Mode: DHCP
User ID: Admin
Password: Password
Clarinet Systems, Inc. http://www.clarinetsys.com Page 8

4 SPECIFICATIONS AND PROVISIONS
4.1 Dimensions
• Dimensions (L x W x H in mm): 152 x 88 x 25; (in inch) 6” x 3.5” x 1”
• Weight: 0.5Kg (Hub and AC adapter); 18 oz
4.2 Environment Specifications
• Operating temperature: 0℃~ 40℃
• Humidity: 10% ~90% RH (Non-condensing)
• Storage temperature: -20℃~ 90℃
4.3 AC Adapter Specifications
• Input voltage & current: 5 VDC & 3 Amp, 2.1x5.5mm plug, center positive polarity
• Plug: 2.1x5.5mm, center positive polarity
• Regulation: UL and <PS>E for Japanese version only
4.4 Safety and EMI certificate
• CE and FCC – B
• VCCI (application in process)
Note: Please check the Data Sheet on www.clarinetsys.com for updated product information.
Clarinet Systems, Inc. http://www.clarinetsys.com Page 9

5 FUNCTIONS AND COMPATIBILITY
5.1 Protocols
5.1.1 Communications protocols
• HTTP
5.1.2 Network protocols
• TCP/IP, DHCP, WINS, DNS
5.1.3 Network connection side
• IP Address: Acquired from DHCP server or manually set
• Applicable Standards: IEEE802.3 (10BASE-T), IEEE802.3u (100BASE-TX),
10/100Mbps (auto negotiation)
5.1.4 PDA connection side
• IP Address: WM5.0 and 6.0 uses DTPT, PPC2003 and earlier uses DHCP provided by
EA104.
• Data transmission speed: Max 12M (USB1.1 is currently enabled although USB2.0
capable)
5.1.5 PDA Compatibility
• CE5.0; Pocket PC 2003/2003SE, Windows CE.NET4.1/4.2, and Windows Mobile 5.0
and 6.0 PDA and PDA phone.
5.1.6 Communications Procedures
• EtherUSB will be recognized as an Access Point on the network
• Once the PDA is connected, the PDA will be recognized as a network terminal
• All configurations are done via HTTP using a browser on PC
5.2 EA104 Firmware version
• For the current Firmware Version, please check http://www.clarinetsys.com
Clarinet Systems, Inc. http://www.clarinetsys.com Page 10
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Punto de acceso inalámbrico de Clarinet Systems

Clarinet Systems
Clarinet Systems SyncHUB ES608 Manual de usuario

Clarinet Systems
Clarinet Systems ESB301 Manual

Clarinet Systems
Clarinet Systems ESB101 Manual de usuario

Clarinet Systems
Clarinet Systems ESB301 Manual de usuario

Clarinet Systems
Clarinet Systems EthIR LAN ESB1000 Manual de usuario

Clarinet Systems
Clarinet Systems ESB208 Manual de usuario

Clarinet Systems
Clarinet Systems ESB301 Manual

Clarinet Systems
Clarinet Systems EtherUSB EA104 Manual de usuario

Clarinet Systems
Clarinet Systems EtherUSB EA104 Manual de usuario

Clarinet Systems
Clarinet Systems ESB301 Manual de usuario