5. Network Connection
The CitySync 30 camera must be connected to a 10/100/1000 Base-T(X) network that routes through
to the computer running the CitySync ANPR software.
The default IP address of the CitySync 30 camera is:
192.168.127.10
The address of every CitySync 30 camera on a given network must be unique and appropriate for
communication with the ANPR computer. Installed as part of the ANPR software suite is an application
called CitySyncFinder.exe. This can be found at:
C:\ANPR\Utilities\CitySyncFinder
The application can be used without the CitySync license dongle and can, for example, be copied over
to a laptop to aid on site installations. In addition to the application, “MDNS.dll” and “CsChilkat.dll”
must also be copied.
With the CitySync 30 connected to the network and powered up, start the CitySyncFinder application.
The application will automatically start scanning for cameras connected to the network and as they
are found they will be displayed as shown:
The cameras IP address can only be changed if its network matches the subnet of the computer
running the CitySyncFinder application. It is therefore recommended that the laptop/PC being used
has its IP address configured to:
192.168.127.xxx
Where xxx can be in the range of 1 to 255 (accept 10, which is used by the camera itself.)
The camera’s address can be programmed to any legitimate address. If the IP address of the camera
to be programmed does not match the computers subnet it will appear greyed out, as camera number