Item Item Description
150% 1 minute; 180% 1 second;200% transient protection
Optimal space voltage vector PWM modulation
Speed sensorless vector control(SVC)
digital setting:Max.frequency 0.01%
Analog setting:Max.Frequency 0.2%
Overload capacity
Modulation method
Control method
Frequency accuracy
Control function
Digital setting:0.01Hz
Analog setting:Max.Frequency 0.1%
Frequency
resolution
0.00 10.00Hz
Starting frequency
Automatic torque lifting:Tolift the torque a
utomatically according to the output current.
Hand-operated torque lifting:Range:0.1 30.0%
Torque lifting
Setting range:0 150%.The inverter output
frequency can be auto-regulated within thisrange
acdording to the motor load soas to reducethe speed
variation of the motor due toload fluctuation.
Slip compensation
0.1 3600.0 sec/min,which can be set insequence.
Acceleration/
deceleration time
1.0 15.0 KHz
Carrier frequency
Jog frequency range:0.01 400.0Hz Jog
acceleration/deceleration time, 0.1~3600.0 can be set.
Jog function
1.linear curve; 2.quadratic curve(conic);
3.User defined V/F curve
V/F curve
Three-phase 0 input voltage VAC
0.00 400.00Hz
Rated voltage
Frequency
Ouput
Rated voltage,frequency Single/three-phase 220VAC,three-phase 380VAC,50Hz/60Hz
Input
Allowable voltage
range
Voltagefluctuation range:-20% +20%
Voltage unbalance rate 3%; frequency fluctuation 5%
Auto optimize V/F curve according toload
fluctuation to realize energy-saving operation.
Automatic
energy-saving
operation
Control function
-10--10-
Chapter 2 Introduction to the Product
Item Item Description
When the network voltage changes,it canregulate
PWM output automatically to maintain constant
voltage.
Auto voltage
regulation(AVR)
This can form a convenient closed-loopcontrol
system(CLCS),and is applicable to pressure control,
flow control and other process control.
Built-in PID
Control function
operator panel control,external terminal control
and COM control
Operating command
Panel potentiometer setting,operator panel
setting,external terminal up/down setting,analog
voltage signal or external potentiometer setting,
analog current signal setting,analog assembly
setting,485 COM setting and etc.
DC braking
Forward/Reverse signal,multiple speed signal,
failure signal,reset signal and etc.
Input Signal
Programmable relay,open-collector output,failure
signal output and etc.
Output signal
This can realize the output offrequency,current and
other physical quantity by outputting 0 10V or
0 20mA DC signal and0 10KHz digital signal.
Multi-function
analog and digital
ouput terminal
Operating function
With an external braking resistor,the maximum
braking torque may reach 100%.
Dynamic braking
This can be selected when themotor starts or stops
with the action frequency of 0 20Hz,action current
level of 0 100% and actuation time of 0 30 sec.,
which can be set in sequence.
DC braking
Braking function
-11--11-
Chapter 2 Introduction to the Product
2.5 Technical Indications
Table 2-2 DscriptionSummary for Technical Indications