Chattanooga Group Hydrocollator SS Manual de usuario

User Manual
120 - Volt Units
Hydrocollator
HEATING UNITS
ISO 13485 CERTIFIED
Moving
Rehabilitation
Forward™
SS
E-2
E-1
M-4
M-2
SS-2
®


1
Foreword. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Precautionary Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Cautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Description of Device Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Nomenclature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-10
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-18
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19-20
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Hydrocollator®is a registered trademark of Chattanooga Group
HotPac™is a trademark of Chattanooga Group
Comet® of Prestige Brands, Inc.
Soft Scrub® of the Dial Corporation
Scotch-Brite™ of 3M
©2008 Encore Medical, L.P., and its affiliates, Austin, Texas, USA. Any use of editorial, pictorial or layout
composition of this publication without express written consent from Chattanooga Group of Encore Medical,
L.P. is strictly prohibited. This publication was written, illustrated and prepared for print by Chattanooga Group
of Encore Medical, L.P.
TABLE OF CONTENTS Hydrocollator®Heating Units

2
This manual contains general instructions for operation, precautionary instructions, and
maintenance recommendations for the owners and operators of the Hydrocollator SS, SS-2,
E-1, E-2, M-2, and M-4 Heating Units. In order to obtain maximum life and efficiency of the
Hydrocollator Heating Units, please read this manual thoroughly and follow all instructions
prior to operating the unit.
Specifications put forth in this manual were in effect at the time of publication. However,
owing to Chattanooga Group's policy of continual improvement, changes to these
specifications may be made at any time without obligation on the part of Chattanooga
Group.
FOREWORD Hydrocollator®Heating Units
SAFETY PRECAUTIONS
The precautionary instructions found in this section and throughout this manual are indicated by specific
symbols. Understand these symbols and their definitions before operating this equipment. The definitions of
these symbols are as follows:
= CAUTIONS - Text with a “CAUTION” indicator explains possible safety infractions that could have the
potential to cause minor to moderate injury or damage to equipment.
= WARNINGS - Text with a “WARNING” indicator explains possible safety infractions that will
potentially cause serious injury and equipment damage.
= DANGERS - Text with a “DANGER” indicator explains possible safety infractions that are imminently
hazardous situations that would result in death or serious injury.
NOTE: Throughout this manual, “NOTE” may be found. These notes are helpful information to aid in the
particular area or function being described.
Precautionary Definitions

3
SAFETY PRECAUTIONS Hydrocollator®Heating Units
Read, understand, and practice the precautionary and operating instructions. Know the limitations associated with the
Hydrocollator SS, SS-2, E-1, E-2, M-2, and M-4 Heating Units. Observe the cautionary and operational decals installed on the
unit.
DO NOT operate this unit in an environment where other devices are being used that intentionally radiates electromagnetic
energy in an unshielded manner. Portable and mobile RF communications equipment can affect Medical Electrical
Equipment.
The Hydrocollator Heating Unit generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to other devices in the vicinity. However, there is no
guarantee that interference will not occur in a particular installation. Harmful interference to other devices can be determined
by turning the Hydrocollator Heating Unit on and off. Try to correct the interference using one or more of the following:
reorient or relocate the receiving device, increase the separation between the equipment, connect the equipment to an
outlet on a different circuit from that which the other device(s) are connected and consult the Chattanooga Group Service
Department for help.
Do not use accessories other than those supplied with the Hydrocollator Heating Unit or recommended by Chattanooga
Group. The safety of other products has not been established, and their use could result in injury to the patient.
Never adjust the thermostat too high. The thermostat is extremely sensitive and the slightest adjustment will alter the
temperature several degrees. The recommended operating temperature is 160° F to 165° F (71° to 74° C). The temperature of
the water should be checked with a thermometer after every adjustment, before using the HotPac. Always allow sufficient
time for the water temperature to stabilize.
The Hydrocollator Heating Unit should not be installed above a surface that is susceptible to casual water damage.
Always keep the water level over the top of the HotPacs to avoid burning or scorching of the packs.
Never allow the HotPac to dry after use.
Check water level daily as it has a natural loss due to evaporation.
Clean the tank as described in the maintenance portion of this manual.
Check unit periodically for signs of leaking and contact service if leaks are noted.
Always replace Hydrocollator HotPacs as soon as they show signs of wear.
If the unit is to be left unattended for a period of time, unplug the unit, remove the packs, empty the water, and clean the
tank.
Do not move the Hydrocollator Heating Unit while filled with heated water. Tipping over could result in burns to the user or
others.
Always unplug the Hydrocollator Heating Unit from the power source before attempting to empty water from unit.
Always use factory authorized replacement parts.
Always destroy and replace HotPacs which are exposed to contamination: hazardous or cleaning materials, bodily fluids,
mold, etc.
This unit should be operated, transported, and stored in temperatures between 0° F and 140° F (-18° C and 60° C) and
atmospheric pressure range between 50 kPa - 160 kPa, with relative humidity ranging from 10% - 100%.
Treatment time should not exceed 30 minutes.
DO NOT retrieve HotPacs from tank or replace HotPacs in tank with unprotected hand.
Avoid direct contact with mounting rack in tank.
Always wrap HotPac with towel or terry cover before handling or applying to patient.
Constantly monitor HotPac application to ensure that the skin is not becoming too hot.
Damage to skin can occur from exposure to extreme heat or cold. Note instructions for proper use.
DO NOT apply over insensitive skin or in the presence of poor circulation.
Never lay or sit on top of the HotPac.
DO NOT use HotPac directly over cuts, abrasions or wounds.
Consult health care professional before using HotPacs on non-communicative individuals.
Exercise extreme caution when using HotPacs on non-communicative individuals.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
CAUTION

4
•Grounding the Hydrocollator SS, SS-2, E-1, E-2, M-2, and M-4 Heating Units: Make certain the unit is electrically grounded by plugging
into a hospital grade electrical outlet with a ground terminal receptacle (U-ground outlet). Follow the National Electrical Code.
•The water temperature in the Hydrocollator Heating Unit is approximately 60° F (71° C), and the water scalding temperature is
approximately 120° F (49° C).
•Care must be taken when operating the Hydrocollator Heating Unit adjacent to or stacked with other equipment. Potential
electromagnetic or other interference could occur to this or other equipment. Try to minimize this interference by not using other
equipment in conjunction with it.
The Hydrocollator Heating Unit should be placed on a smooth, level surface. The surface should support up to the Filled Weight (weight
of heating unit filled with water) found in the Technical Specifications pages 8-10 of this manual.
•Use only accessories that are specially designed for the Hydrocollator Heating Unit. Do not use accessories manufactured by other
companies on the Hydrocollator Heating Unit. Chattanooga Group is not responsible for any consequence resulting from using
products manufactured by other companies. The use of other accessories or cables may result in increased emissions or decreased
immunity of the Hydrocollator Heating Unit.
•Periodically inspect unit for signs of damage and pitting during regular cleaning intervals, as described in maintenance portion of this
manual. Contact service if any signs of damage are discovered.
•DO NOT apply HotPac directly to skin.
•Individuals with circulatory problems should consult with a physician before using this product.
•DO NOT sit or lie on the HotPac.
•DO NOT add chlorine additive to water.
•DO NOT allow HotPac to come in contact with hydrocarbons (e.g., Comet®, Soft Scrub®, etc.).
WARNING
Risk of explosion if used in the presence of flammable anesthetics.
ATTENTION: Refer to Instruction Manual/Booklet
Type B equipment
Description of Device Markings
Thermostat Intensity Control
SAFETY PRECAUTIONS Hydrocollator®Heating Units

5
NOMENCLATURE Hydrocollator®Heating Units
WHITE LAMP, when illuminated, indicates that main power is connected, the switch is on and
unit is operating.
RED LAMP (M-4 units), when illuminated, warns of an overheat/low water condition. Action is
necessary to correct the condition.
IMPORTANT: Some models (M-4 units) are fitted with a thermal cut-out thermostat which
acts as a “non self-resetting” thermal cut-out. In the unlikely event of a fault condition, this
device is designed to open the power circuit between 190° F ± 14° F (88° C ± 8° C). It is not
possible to alter its operating range. The operation of the unit may be restored by depressing
the red button after the water/element temperatures have been allowed to cool. If the fault
condition persists, please contact Chattanooga Group or an authorized agent.
White Lamp

6
NOMENCLATURE Hydrocollator®Heating Units
Rear view E2
3
1. Lid
2. Lid Rod
3. Pilot Lamp, Clear
4. Power Cord
5. On/Off Switch
6. Thermostat Intensity Control
7. Drain Valve
8. Heating Element
9. Drain
10. Hydraulic Thermostat
11. Bracket (Bracket & Bulb Thermostat A/B
Assembly)
12. Internal Wiring Harness
13. Drain, Copper Tube
NOTE: E-2 and E-1 models shown above; models will vary. Nomenclature also applies to SS, SS-2, M-2 and M-4 models.
5
8910
E-1 Rear View
12
Rear View
Underneath View
(J-Box Cover Removed)
Inside View
1
4
6
7
11
2
13
E-2 Model
Diagram

7
14. Lid Knob/Handle
15. Lid Rod Nuts
16. Side Handle
17. Casters, 3-inch
18. Neck Pak Insert
19. HotPac
20. Overtemp Thermostat*
21. Overtemp Reset Button*
22. Overtemp Light Cover*
23. Pilot Lamp, Red*
24. Junction Box (J-Box) Cover
NOMENCLATURE Hydrocollator®Heating Units
18
Not illustrated:
25. Stainless Steel Wire Rack
26. Drain, Hose, Bib
27. Replacement Tank
28. Outer Jacket
29. Water Thief
30. Plastic Feet
31. Hose, Drain
32. Drain, Copper, Part B (SS only)
33. Bracket, Element Support
15
19
Rear View
Inside View
* M-4 units only
14
24
17
M-4 Model
20
22
21 23
Diagram (CONTINUED)
NOTE: M-4 model shown above; models will vary. Nomenclature also applies to E-1, E-2, SS, SS-2, and M-2 models.
16

8
TECHNICAL SPECIFICATIONS Hydrocollator®Heating Units
Power Supply 110-120 V~
Rated Frequency 50 Hz
Power Consumption 1000 W
Tank Capacity 31.64 Liters
Filled Weight 56 kg (120 lbs)
Temperature Range 160° F - 165° F (71° C - 74° C)
Thermal Cut-out Temp 190° F ± 14° F (88° C ± 8° C)
Heating Up Time Time to 160° F (70° C) - 3 Hours
Cool Down Time Time from 160° F (70° C) - 2 Hours
Safety Class Type B
Safety Tests UL 544
Dimensions 20 in H x 18 in L x 16 in W (51 cm H x 46 cm L x 41 cm W)
Product Weight 51 lbs (23.1 kg)
Shipping Weight 54 lbs (24.5 kg)
Standard Accessories: Includes eight Standard size HotPacs.
SS-2 Model
Power Supply 110-120 V
Rated Frequency 60 Hz
Power Consumption 1000 W
Tank Capacity 49.32 Liters
Filled Weight 85 kg (140 lbs)
Temperature Range 160° F - 165° F (71° C - 74° C)
Thermal Cut-out Temp 190° F ± 14° F (88° C ± 8° C)
Heating Up Time Time to 160° F (70° C) - 4 Hours
Cool Down Time Time from 160° F (70° C) - 2 Hours
Safety Class Type B
Safety Tests UL 544
Dimensions 33 in H x 21 in L x 16 in W (85 cm H x 52 cm L x 39 cm W)
Product Weight 68 lbs (30.8 kg)
Shipping Weight 74 lbs (33.6 kg)
Standard Accessories: Includes eight Standard size HotPacs.
SS Model
Este manual sirve para los siguientes modelos
5
Tabla de contenidos
Manuales populares de Calentador de otras marcas

Empire Heating Systems
Empire Heating Systems WCC65 Manual de usuario

Wetekom
Wetekom 92 86 43 Manual de usuario

Desa
Desa SPC170-F Manual de usuario

Watlow
Watlow Watrod Electric Tubular Heaters Manual de usuario

Haverland
Haverland ECO-DRY GPS Series Manual de lista de piezas

Stelpro
Stelpro ASILVC2060 Series Manual de usuario