Centrometal EKO-CKS P UNIT controller Manual del propietario

EKO-CKS P UNIT
HEATING TECHNIQUE
Centrometal d.o.o. - Glavna 12, 40306 Macinec, Croatia, tel: +385 40 372 600, fax: +385 40 372 611
TU-R-CKSP-3-2022-v1.12v-ENG
TECHNICAL INSTRUCTIONS
Description and using of EKO-CKS P UNIT
controller
- USER
THE FIRST START-UP MUST BE DONE BY AUTHORIZED PERSON,
OTHERWISE PRODUCT WARRANTY IS NOT VALID.
ENG

If the language selection is "disabled" (display > language selection > OFF), initial message wil appear
in the screen as long as the set in the menu "Welcome time" (display > Init. message time).
Button’’OK’’
Initial message duration
(countdown)
Boiler power
(140, 180, 230, 280, 320
430, 499, 560 kW)
Software version
Software version
Language selection
Boiler power
(140, 180, 230, 280, 320
430, 499, 560 kW)
When turning the main switch the screen should not be pressed (by finger...). If
the screen when you turn the main switch is pressed (on the screen labeled
"Firmware update") regulation is in ”software update“ that can be used by
authorized personnel only. If this happens, it is necessary to turn off the main
switch and restarted without any pressure on the display.
After turning on the main switch, screen will display language selection menu and software version. To
select the language, press the flag of language you want.
SWITCHING ON
DESCRIPTION
Technical instructions REGULATION EKO-CKS P UNIT
2

RIGHT SIDE TOOLBAR
1
2
3
4
5
LEGEND:
1 - Time & Date
2 - Display selection - Main menu / Main screen
3 - Dropdown menu
4 - State of the current boiler status (working phase)
5 - Boiler Start / Stop
1
2
3
4
5
Technical instructions REGULATION EKO-CKS P UNIT 3

Button ’’START’’/’’STOP’’
Button ’’ON / OFF’’
options: on / off boiler operation’’
Button ’’DISPLAY SELECTION’’
options: main menu / main screen
Button ’’BOILER OPERATION DISPLAY’’
Options: graphic / numeric display /
additional equipment
Button ’’ENTER’’
Button ’’BACK’’
Button’’PREVIOUS SCREEN’’
Button ’’NEXT SCREEN’’
Button ’’OK’’
Navigation buttons:
’’LEFT’’, ’’RIGHT’’, ’’UP’’, ’’DOWN’’
Button ’’DELETE’’
Button ’’FACTORY SETTINGS’’
Button ’’INFORMATION’’
Button ’’COPY’’ Button ’’PASTE’’
MAIN MENU
The main menu is used to select the desired submenu. To select a specific menu you must press the
appropriate icon on the screen. To switch between the ’’Main menu’’ and ’’Main screen’’ press the
button ’’Display selection’’.
BUTTONS
Technical instructions REGULATION EKO-CKS P UNIT
4

SYMBOLS
The pump has a request for work (next to the pump symbol bright yellow square when
the consumer given the demand for work the pump, the pump does not work if you have
not met all the conditions for work, for example. low temp. in the boiler, otherwise the
pump normally works)
Pump (when pump is working symbol is rotating, otherwise idle)
70°C
50°C
Accumulation tank with current
temperature at top of the tank and
at the bottom of the tank.
60°C
Hydraulic crossover with the current
temperature
55°C
Domestic hot water tank
with current temperature
Heating circuit
Room thermostat
Next to the room thermostat
symbol bright blue circle (the
room thermostat has requested
for operating the pump, the pump
does not work if you have not met
all the conditions for its operation,
for example. low temp. in the
boiler, otherwise normally works)
60°C
Hydraulic crossover
External start enabled
External start disabled
External start disabled;
enabled start of the boiler
via schedule
External control:
enabled work
(button ON)
External control request
boiler to work
External control doesn’t
request boiler to work
Display / Drop-down menu button
(all existing elements of automatic /
remote boiler start are included)
Technical instructions REGULATION EKO-CKS P UNIT 5

Preview boilers
in cascade
Heating + DHW mode
Cyclone with fan
Pellet tank
with screw
feeder
Compressor symbol with
work indicator (on / off).
Dispenser
Alternative boiler: Manual OFF
Alternative boiler: Manual ON
Alternative boiler: AUTO START
Alternative boiler: ON
Alternative boiler: OFF
Alternative boiler: FREEZE ON
Auxiliary boiler
CM-GSM module network status
Regulation is connected with
web portal (internet supervision
is possible)
Regulation is not connected with
web portal (internet supervision
is not possible)
AUTO
PTV < > Grij. + PTV
mode
DHW mode
Refilling the pellet tank from the large pellet tank:
Screw feeder + three-phase motor
2x screw feeder + three-phase motor
2x screw feeder + three-phase motor + sensor
Technical instructions REGULATION EKO-CKS P UNIT
6

MAIN SCREEN
1 - Boiler temperature
2 - Working hours counters
3 - Cyclone ((140-430 kW) if is installed and configured) (Additional equipment for
EKO-CKS P UNIT 140-430, standard equipment for EKO-CKS P UNIT 499-560)
4 - Pellet tank with feeder screw
5 - Pellet burner
6 - Automatic cleaning system of the heat exchanger's flue gas tubes (passages) by air (pneumatic)
(Additional equipment)
7 - Automatic ash removal system out of the boiler combustion chamber (spiral)
(Additional equipment)
8 - Ash box (if is installed)
9 - Automatic ash removal system out of the flue gas chamber (spiral) (Additional equipment)
10 - Compressor
11 - Flue gas temperature
12 - Alternative boiler / Auxiliary boiler
13 - Depend about configuration
14 - Network status (CM-GSM/WiFi) (if is installed - additional equipment)
15 - Work mode
16 - Errors / Warnings
17 - Outdoor temperature
18 - Dispenser (Additional equipment)
19 - Refilling
1
2
4
6
7
5
8
10
13
18
15
12
14
3
916
11
17
19
Technical instructions REGULATION EKO-CKS P UNIT 7

DROPDOWN MENU
Dropdown menu
By pressing button for boiler
operation on display will be
displayed dropdown menu for
acces to configurated equipment.
Additional equipment can be managed through dropdown menu on main screen of boiler control unit.
Additional equipment managment by dropdown menu
3
By pressing button for boiler operation (1) on display will be displayed dropdown menu. By pressing
button for additional equipment managment (2) on display will be displayed menu for additional
equipment managment where is possible to turn on / off additional equipment. Additional equipment
menu depend about installed and configured additional equipment.
2
1
Technical instructions REGULATION EKO-CKS P UNIT
8

Domestic hot water managment by dropdown menu (if is installed and configured)
3
By pressing button for boiler operation (1) on display will be displayed dropdown menu. By pressing
button for domestic hot water managment (2) on display will be displayed menu for DHW managment
where is possible to turn on / off domestic hot water.
Regulator (if is installed and configured)
By pressing button for boiler operation (1) on display will be displayed dropdown menu. By pressing
button for regulator (2) on display will be displayed heating circuit preview.
2
1
2
1
Cascade managment by dropdown menu (if is installed and configured)
By pressing button for boiler operation (1) on display will be displayed dropdown menu. By pressing
button for cascade managment (2) on display will be displayed menu for cascade managment. By
pressing button (3) is possile to start / stop boiler in cascade. On toolbar (4) are showned which of
SUMMER / WINTER mode is active.
3
4
2
1
Technical instructions REGULATION EKO-CKS P UNIT 9

BOILER OPERATION PHASES
"OFF" - burner OFF
"S0" - initial fan blowing
"S1" - filling without fan
"S2" - filling with fan
"C0" - waiting for flame to appear
"C1" - stabilisation stage 1
"C2" - stabilisation stage 2
"C3" - stabilisation stage 3
"P1" - power 1
"P2" - power 2
"P3" - power 3
"P4" - power 4
"P5" - power 5
"A0" - extinguishing, waits for flame disappearing
"A1" - fan blowing
"A2" - pause, the boiler is waiting for the conditions to start
"PF0" - operation after el. power failure
"PF1A" - operation after el. power failure
"PF1B" - operation after el. power failure
"PF2" - operation after el. power failure
"PF3" - operation after el. power failure
Phase of burner operation
Technical instructions REGULATION EKO-CKS P UNIT
10
Tabla de contenidos