CenRF ICS Manual de usuario

ICS Smart Indoor Repeater
for
WCDMA Mobile
User Manual
V1.0
CenRF Communications Limited

ICS Smart Indoor Repeater
CenRF Communications Limited www.cenrf.com Page 1 of 13
Contents
Introduction.......................................................................................................................................... 2
1Installation...................................................................................................................................... 3
1.1 The Setting of application..................................................................................................... 3
1.2 Schematic Diagram of Installation...................................................................................... 4
1.3 Description on the Indicated Info of the Overall Unit’s LCD ........................................... 6
2Device Debugging........................................................................................................................ 8
2.1 Preparation............................................................................................................................. 8
2.2 Device Debugging................................................................................................................. 8
3Specifications.............................................................................................................................. 11
4Precautions.................................................................................................................................. 12

ICS Smart Indoor Repeater
CenRF Communications Limited www.cenrf.com Page 2 of 13
Following instruct application and configuration of Smart Indoor Repeater.
Introduction
These Application Instructions have provided a description, installation guide and
recommendations on the hardware of facilities in miniature ICS repeater system as well as their
software opening and debugging, including system overview, safety precautions on the installation
work, the requirements on installation site and installation preparations. You are kindly requested
to read theseApplication Instructions before installing and setting up the miniature ICS device and
then follow the steps and procedures described hereunder.

ICS Smart Indoor Repeater
CenRF Communications Limited www.cenrf.com Page 3 of 13
1 Installation
1.1 The Setting of application
House
basement
Office building
The signal power
beside the windows≥
-85dBm will be best!
When the cover area signal
power is≤-85dBm,the effect
will be the best!

ICS Smart Indoor Repeater
CenRF Communications Limited www.cenrf.com Page 4 of 13
1.2 Schematic Diagram of Installation
1.2.1 The Profile of Smart Indoor Repeater Module:
1.2.2 The setting of application for reference is shown below (with WCDMA2100MHz
application as an example)
ICS Repeater

ICS Smart Indoor Repeater
CenRF Communications Limited www.cenrf.com Page 5 of 13

ICS Smart Indoor Repeater
CenRF Communications Limited www.cenrf.com Page 6 of 13
Descriptions on the Setting:
a. The ICS micropower unit is placed indoors, facing any zone to be covered; receiving and
transmitting antenna inside.
b. the uplink isolation between the receiving and transmitting antenna is 42dB and the downlink
isolation is 58dB, so the module’s gain can be generally set to be approx. 68dB.
1.3 Description on the Indicated Info of the Overall Unit’s LCD
1.3.1 The Whole Profile of the LCD
1.3.2 Description on Each Indication on the LCD
LCD Indication
Description
Remarks
The Progress Bar in the left has 6
bars in total:
1. Once the module is powered on,
the Progress Bar will roll
circularly, indicating that the
module is starting;
2. Once the module is normally
started, the Progress Bar will
show the downlink received signal
level strength;
3. In case of failure in startup, all 6
progress bars would be lit,
flashing for alarm.
The indication range of downlink
signal strength:
0: no signal input or no signal
detected;
1 bar: -110~-101dBm ;
2 bars: -100~-91dBm;
3 bars: -90~-81dBm;
4 bars: -80~-66dBm;
5 bars: -65~-51dBm m;
6 bars: ≥-50dBm;

ICS Smart Indoor Repeater
CenRF Communications Limited www.cenrf.com Page 7 of 13
The uplink and downlink indications:
The UP Arrow represents uplink and
the data on the same row is
uplink-related data;
The DOWN Arrow represents
downlink and the data on the same
row is downlink-related data;
The input power value:
The data on the previous row
represents the electric level of input
power in uplink channel;
The data on the next row represents
the electric level of input power in
downlink channel.
The gain value:
The data on the previous row
represents the set gain of uplink
channel;
The data on the next row represents
the set gain of downlink channel.
Isolation:
The data on the previous row
represents the environmental
isolation of uplink channel;
The data on the next row represents
the environmental isolation of
downlink channel.
The Progress Bar in the right has 6
bars in total:
1. For the GSM system, upon
startup of module, in the process
of frequency search, the Progress
Bar will roll circularly.
2. For the GSM system, if the
frequency search failed, flashing
for alarm would occur.
3. During the normal operation, the
number of bars indicates the
condition of current working
environment.
The condition of current working
environment:
1 bar: 19~25 dB;
2 bars: 16~20dB;
3 bars: 11~15dB;
4 bars: 6~10dB;
5 bars: 0~5dB
6 bars: <0dB

ICS Smart Indoor Repeater
CenRF Communications Limited www.cenrf.com Page 8 of 13
2 Device Debugging
2.1 Preparation
Detail of Preparation
Description
Data cable
USB data cable
Computer
Computer
Configuration interface of
overall unit
ICS debugging software
(PICO_ICS_TOOL_EN.exe)
2.2 Device Debugging
Connect the module to the power adapter, approx. 20 seconds later start up the module, then
connect USB data cable to the USB port of the computer and the overall unit and open the
ICS debugging interface.
Open the ICS debugging software (PICO_ICS_TOOL_EN.exe) interface. In case of
connection failure due to incorrect setting of serial ports, the software would pop up a dialog
box indicating connection failure. Then select the current computer’s serial port in the options
of serial port configuration. You may view the computer port in the operating sequence
(computer —— attribute —— hardware —— device manager —— port). The serial port’s
baud rate is 460800 and serial port’s configuration is shown in Figure 2.2.1. once selected
properly, you may view the monitoring interface and in case of connection failure, the basic
data of monitoring interface would be read out. Only after the serial port was properly
configured could sequent operation proceed.
Figure 2.2.1
The settings of module’s monitoring interface for reference are detailed as follows:
The following screenshot is data reading in the setting of application for reference. Please
refer to the instruction concerning the use of this interface behind each screen shot in the
configuration.

ICS Smart Indoor Repeater
CenRF Communications Limited www.cenrf.com Page 9 of 13
Screenshot of Downlink and Uplink Setting
Description of Basic Setting Parameters:
CH NUM: See the Specifications for the maximum number of channels supported by the overall
unit based on the practical environmental setting; Up and down the line frequency point linkage
(just Settings horizontal frequency point, ascending will automatically associated the
corresponding frequency point)
Gain: According to external isolation degree automatic Settings, the biggest gain 75 db
Output power: Module of the total output power, the default Settings for downlink 13 DBM, every
15 DBM, each channel power divide (total power divide to open each channel)
Attenuation: To set the overall unit’s gain attenuation
EN: Open and close the channel based on the number of channels used; Electromagnetic linkage
(will open channel after the uplink channel corresponding also open)
Description of Work Control Parameters:
Downlink: ON means that it is under normal operating condition;
OFF means that downlink is closed and there is no output signal from the module;
Uplink: ON means that it is under normal operating condition;
OFF means that downlink is closed and there is no output signal from the module;
ICS: ON means that the feedback inhibition function is enabled (the uplink and downlink of this
switch must be under the same condition, i.e. switch on or off simultaneously);
OFF means that the feedback inhibition function is disabled;
Up link Noise Suppression: Select Not Working;
ICS protect: Select Working.
Threshold(dB): Gain binding isolation degree value (suggest setting for 17)