CEM LDM-40 Manual de usuario

Please read this manual before switching the unit on.
Important safety information inside.
Please read this manual before switching the unit on.
Important safety information inside.
User Manual
Laser Distance Meter
Model: LDM-40
www.tools.in.th
www.tools.in.th

Laser Distance Meter User Manual
www.tools.in.th
www.tools.in.th

.................................................4
..............................................................6
...................................8
.........................................................10
..........................................................11
....................................................15
......17
..........................................18
............................................................19
Safety Instruction
Start-Up
Initial Operation and Setting
Measuring
Functions
9
The compact and handy base model was specifically designed for indoor applications.
Shortcut and Soft grip keys for addition, subtraction, area and volume calculation make
measuring fast and very reliable.
1.
2.
3.
4.
5.
6.
7.
8.
.
Technical Data
Troubleshooting-Causes and Corrective Measures
Measuring Conditions
Labelling
Content
Laser Distance Meter User Manual
3
www.tools.in.th
www.tools.in.th

• Measuring distances
• Computing functions, e. g. areas and volumes
• Using the instrument without instruction
• Using outside the stated limits
• Deactivation of safety systems and removal of explanatory and hazard labels
• Opening of the equipment by using tools (screwdrivers, etc.), as far as not specifically permitted for certain cases
• Carrying out modification or conversion of the product
• Use of accessories from other manufacturers without the express approval of CEM Technology.
• Deliberate or irresponsible behavior on scaffolding, when using ladders, when measuring near machines which
are running, or near parts of machines or installations which are unprotected
• Aiming directly into the sun
• Inadequate safeguards at the surveying site (e.g. when measuring on roads, construction sites, etc.)
1.Safety Instruction
Permitted Use
Prohibited Use
Laser Distance Meter User Manual
4
www.tools.in.th
www.tools.in.th

Laser Classification
The CEM produced a visible laser beam which emerges from the front of the instrument.
Do not stare into the laser beam or direct it towards other people unnecessarily. Eye protection is normally afforded
by aversion responses including the blink reflex.
Looking directly into the beam with optical aids
(e.g. binoculars, telescopes) can be hazardous.
Do not look directly into the beam with optical aids.
Looking into the laser beam may be hazardous to the eyes.
Do not look into the laser beam. Make sure the laser is aimed above or below eye level.
Laser Class 2 products:
:
Precautions:
Precautions:
‘s
WARNING
CAUTION:
Laser Distance Meter User Manual
5
www.tools.in.th
www.tools.in.th

1) Remove battery compartment lid.
2) Insert batteries, observing correct polarity.
3) Close the battery compartment again.
Replace the batteries when the symbol “ “ flashes permanently
in the display.
• Use alkaline batteries only.
• Remove the batteries before any long period of non-use to avoid
the danger of corrosion
1- button
2- button
3- button
4- button
5- ( ) button
6- ( ) button
7- button
•
ON/MEAS
Area/Volume
Indirect measurement
Single/Continous Distance measurement
Plus
Minus
Storage
2 Start-Up.
•
Inserting/Replacing Batteries
Keypad
(
(See “Figure B”)
See “Figure A”)
Figure A
8- button
9- button
10- button
Reference
Illuminating/UNITS
Clear/Off
Figure B
1
2
4
5
7
8
3
6
9
10
Laser Distance Meter User Manual
6
www.tools.in.th
www.tools.in.th

LCD Display (“ ”)See figure C
1- Laser active
2- Reference level (front)
3- Reference level (rear)
4- Variable measuring functions
Area measurement
Volume measurement
Indirect measurement
Indirect (second) measurement
5- Single distance measurement
6- Battery status
7- Historical memory
8- Instrument error warning
9- Continuous measurement & Max and Min measurement
10- First value display line
11- Second value display line
12- Summary line for last measure or calculation result
Laser Distance Meter User Manual
7
Figure C
1
2
3
4
56 7 8
10
11
12
9
www.tools.in.th
www.tools.in.th

.3 Initial Operation and Setting
Switches on the instrument and laser.
Press this button longer to switch off the instrument.
The instrument switches off automatically after three minutes of inactivity.
The last action is cancelled or the data display is cleared. If in the mode of History storage, press Storage
button and Clear button simultaneously will clear all storage data in the memory.
The default reference setting is from the rear of the instrument.
Press this button to take the selection from the front edge ,
A special beep sounds whenever the reference setting is changed.
After a re-startup the reference returns automatically to the default
setting (rear reference).
Switching On and Off
Clear Button
Reference Level Setting (See “Figure D”)
Figure D
Laser Distance Meter User Manual
8
www.tools.in.th
www.tools.in.th

/UNITS
to
Click illumination button of the display can be switched on or off, user can trigger the function when
he/she is in darkness situation. The value is clear visible on the LCD
Click the button longer to change the next type of unit, then continue click the button for
the next unit selection
m, ft. in, ft+in
Display Illumination
Distance Unit Setting For Instrument
Laser Distance Meter User Manual
9
www.tools.in.th
www.tools.in.th

.4 Measuring
Press again to trigger the distance measurement. The measured value is displayed immediately.
The continuous measurement function (tracking) is used for the
transferring of measurements, e.g., from construction plans. In
continuous measurement mode, the measuring tool can be moved
to the target, whereby the measured value is updated approx. every
0.5 seconds in the third line. The corresponding minimum and
maximum values are displayed in the first and second
line. As an example, the user can move from a wall to the required
distance, while the actual distance can be read continuously. For
continuous measurement, push button until the indicator for
continuous measurement appears in the display. And press MEAS
or Clear button again to stop the function. The function is terminated
automatically after continuous 100 times measurement.
Press to activate the laser.
dynamically
Single Distance Measurement
Continuous Measurement (Tracking) & Max and Min Measurement (See “Figure E”)
Figure E
MIN
MAX
Laser Distance Meter User Manual
10
www.tools.in.th
www.tools.in.th
Tabla de contenidos
Otros manuales de Instrumento analítico de CEM
Manuales populares de Instrumento analítico de otras marcas

EXTOL PREMIUM
EXTOL PREMIUM 8820043 Instrucciones de instalación y funcionamiento

RIDGID
RIDGID SeeSnake Compact Manual de usuario

Teledyne
Teledyne 3000PA Manual de usuario

YDLIDAR
YDLIDAR TIA Manual de usuario

Olympus
Olympus IPLEX FX Series Manual de usuario

Bosch
Bosch GLM 50 C Professional Manual de usuario