CDVI AIOM Manual de usuario

AIOM
The installer’s choice
cdvigroup.com
ENGLISH
EN
10-Input/10-Output Module

2cdvigroup.com
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
Thank you for buying our products and for
the condence you placed in CDVI.
TABLE OF CONTENTS
1] PRODUCT PRESENTATION.........................................................3
2] NOTES AND RECOMMENDATIONS ...................................................4
FCC & IC Compliance ......................................................... 4
UL/ULC Compliance .......................................................... 4
UL 294 Compliance Notice ..................................................... 4
Free Technical Support ........................................................ 4
Recommended Wiring......................................................... 5
Specications .............................................................. 5
3] PACKAGE CONTENTS .............................................................6
Content of the 10-Input/10-Output Module .......................................... 6
Location and Mounting ........................................................ 7
4] MOUNTING INSTRUCTIONS .......................................................8
Installing the Tamper Switches .................................................. 8
Installing the box lock ........................................................ 9
Fixing the Box to its Location .................................................. 10
Installing the 10-Input/10-Output Module PC board ................................... 11
5] WIRING DIAGRAM .............................................................12
Connecting the Box Tamper Switches ............................................. 12
Connecting Inputs .......................................................... 13
Examples of Input Connection Methods ........................................... 14
Connecting Outputs ......................................................... 16
LED Indicators............................................................. 17
Connecting the 10-Input/10-Output Module to the ATRIUM 2-Door Controller ................. 18
6] WARRANTY - TERMS & CONDITIONS ..............................................19
Copyright (C) 2012 CDVI. All rights reserved. ATRIUM Access Control is protected by copyright law and international treaties.
Unauthorized reproduction or distribution of this product, or any portion of it, may result in severe civil and criminal penalties,
and will be prosecuted to the maximum extent possible under law.
All other brand and product names are trademarks or registered trademarks of their respective companies.
The information contained in this publication is subject to change without notice.

3
cdvigroup.com
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
1] PRODUCT PRESENTATION
The AIOM 10-Input/10-Output Module module supports 10 zone inputs and 10 outputs. It can be connected to
the ATRIUM 2-Door Controller’s, AC22, anywhere on the 1220m (4000ft) 4 conductor RS485 communication
bus. Effortless auto-detect technology identies the AIOM on the communication bus.
• 10 Inputs (20 using zone doubling technology)
• 10 Outputs
• Auto-detect technology
• Up to 100 AIOM module can be
connected to the AC22
• 1220m (4000ft) 4 conductor RS485 expansion bus
(No jumpers or DIP switches)
• Comprehensive LED status indicators

4cdvigroup.com
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
2] NOTES AND RECOMMENDATIONS
FCC & IC Compliance
This device complies with Part 15 of the FCC rules Class A. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received
including interference that may cause undesired operation. This class A digital apparatus meets all requirements
of the Canadian Interference Causing Equipment Regulations. The ATRIUM AIOM 10-Input/10-Output Module is
also compliant with EN55022:1998, amendment 1:1995, Class A.
UL Compliance
To comply with UL listings, the following requirements must be met:
• Use of UL listed readers (Wiegand: 26-bit, 30-bit and 40-bit; mag stripe: up to 32 digits)
• Use of a UL recognized tamper switch on every housing cabinet for the AIOM
• Use only UL listed cables
• Use only UL listed adaptors
Note: All circuits are power limited.
UL 294 Compliance Notice
• Use only UL listed power supply
• Connect CDVI LED status indicator, part number 7020-0001-0000, to the DC Input gray terminals of
the AIOM.
Note: Backup battery provides operation of up to 12 hours but has been tested for 4 hours per
Section 33 of UL 294, fth edition.
The system’s location and wiring methods shall be in accordance with the National Electrical Code,
ANSI/NFPA 70.
Free Technical Support
For technical support in Canada or the U.S., call 1-866-610-0102, Monday to Friday from 8:00 a.m. to 8:00
p.m. EST. For technical support on the International, please see the last page of this document or visit our web-
site: www.cdvigroup.com.

5
cdvigroup.com
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
Recommended Wiring
Specications
Equipment Wire Type Size Maximum
Length
Zone input and output 2 conductors, copper 22AWG (0.64mm) 22AWG (0.64mm) 600m (2000ft.)
RS485 bus, Star or
Daisy Chain (no BIAS/
EOL required)
CAT 5/5e or 4 pairs 24AWG (0.51mm)
1220m (4000ft.)
4 conductors, copper 26AWG (0.40mm) to
18AWG (1.02 mm)
System Resources
Operating Temperature -20°C to +70°C (-4°F to +158°F)
Humidity 0% to 85% (non condensing)
System Autonomy Full Distributed Architecture (100% Off-line Operation)
Firmware Online Upgradeable
PCB Dimensions 19.5cm (7.68”) x 8.9 cm (3.5”)
Cabinet Dimensions 29 cm (11.4”) high, 28 cm (11”) wide, 8 cm (3.15”) deep
Inputs
Multi-Purpose Inputs 10 zone inputs (up to 20 using ZONE DOUBLER) with optional individual WIRE CUT &
WIRE SHORT supervision.
Smoke Detector Future use
Box Tamper Normally Closed (N.C.) contact
Outputs
Multi-Purpose Outputs 10 outputs open collector 100mA
Communication
LOCAL BUS RS485 @ 57600Baud supporting star and/or daisy chain topologies up to 4000ft (1220 meters)

6cdvigroup.com
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
3] PACKAGE CONTENTS
This chapter details how to install and setup the ATRIUM 10-Input/10-Output Module.
Content of the 10-Input/10-Output Module
The 10-Input/10-Output Module contains:
• One 10-Input/10-Output Module module in its cabinet with connection diagram label
• Metal Box kit:
• Installation kit:
If any item is missing, please notify your distributor immediately.
Wall Switch
and a white
wire (115mm)
with a log at
each end
Bolts and Nuts Wall Switch
Spacer
Door Switch
and 2 white
wire (350mm)
with a log at
one end
Door Switch
Support
Metal box
screw
Metal box
lock and key
Metal Box Kit 1211141
1K Resistor 2.2K Resistor Fastener
(PCB Holder)
Installation
Kit 21 10 5

7
cdvigroup.com
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
Location and Mounting
The cabinet is designed to be installed indoors, in a safe and secure location. Suggested locations include
electrical rooms, communication equipment rooms, closets or in the ceiling. To save time, wiring and facilitate
testing, install the cabinets at an equal distance between its controlled doors. Normal temperature and humidity
levels should be maintained.
Cabinet Dimensions:
29 cm (11.4”) high, 28 cm (11”) wide, 8 cm (3.15”) deep
Multiple Conduit Knock-outs:
Two 19.05mm (0.75”) on each side and one 12.7mm (0.5”) on top
Minimum Clearance For Cabinet:
25cm (10”) clear space around all sides
38cm (15”) clear space in front of cabinet
Minimum Clearance From Electrical Interference:
2.4m (8ft.) from high voltage equipment or wiring and from electrical equipment likely to generate
interference
1.2m (4ft.) from telephone equipment or lines and 8m (25ft.) from transmitting equipment
The system’s location and wiring methods shall be in accordance with the National Electrical Code,
ANSI/NFPA 70.

8cdvigroup.com
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
4] MOUNTING INSTRUCTIONS
Cabinet Side View
Cabinet Door
Nut
Spacer
Spacer
Screw
Spacer
Install the wall tamper switch using the supplied bolts and nuts as shown in the following picture.
Install the tamper switch
plastic spacer on the
back at bottom left side of
the box as show in
the following picture.

9
cdvigroup.com
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
Fix the tamper switch to
the bracket then mount
the bracket on the
mounting flange
Door
Tamper Switch
Bracket
Door Tamper Switch
Mounting Flange
Install the door tamper switch by aligning the switch holes to the pre-installed plastic bracket pins. Press rmly
to secure the tamper switch in position, then x the bracket to is mounting ange.
Refer to page <?> for wiring diagram.

10 cdvigroup.com
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
EN
AIOM
10-Input/10-Output Module
INSTALLATION MANUAL
Installing the box lock
Installing the box lock allows to secure the box from non
authorized access. If needed install the box lock as shown
in the following picture.
1. Remove the box door knock-out.
2. Insert the lock in the hole.
3. Slide the “U” metal part into the lock groove.
Alternatively or complementary to the box lock,
the box may be secured by xing the cover to
its base using screws.
However this should be done only once the
installation of the 10-Input/10-Output Module
system is completed.
1. Use the 4 screws supplied to secure
the box cover to its base as shown
in the following picture.
Tabla de contenidos
Manuales populares de Sistema de E/S de otras marcas

WAGO
WAGO 750-344 Manual de usuario

Teknim
Teknim TWM-1887 Manual de instrucciones

Intelligent Appliance
Intelligent Appliance IA-2662-E Manual de usuario

BERGHOF
BERGHOF ECC DIO 16/16 Manual de instrucciones

Advantech
Advantech PCM-27J3AU Manual de instalación y operación

Festo
Festo CP-E08-M12-CL Manual de usuario