Cansec CP40 Manual de usuario

CP40 Controller
INSTALLATION MANUAL
October 2015


CP40 Page 3 of 43
Installation Manual October 2015 • Rev. 2.7
Table of Contents
Introduction.............................................................................................................................. 5
Specifications........................................................................................................................... 6
CP40 Controller Layout ........................................................................................................... 8
Important Installation Notes.................................................................................................... 9
New Panel Installation Instructions.......................................................................................10
Power up the Panel.......................................................................................................10
Set the Panel Address...................................................................................................10
Clear the Panel Memory................................................................................................11
Onboard LEDs.........................................................................................................................12
Communication LEDs....................................................................................................12
Firmware Status LEDs...................................................................................................12
Reader Status LEDs......................................................................................................12
Options DIP Switch (S2)................................................................................................13
Baud Rate DIP Switch (S3) ...........................................................................................14
Reader Type DIP Switch (S5)........................................................................................14
Communications Wiring.........................................................................................................15
Using a CLAUSB (RS-485)............................................................................................15
Using a CANLAN (RS-485) ...........................................................................................16
Using AIR-485 (RS-485)................................................................................................17
Lock Output Relay Wiring ......................................................................................................19
Electric Strikes up to 250MA (Internal Power Supply)....................................................20
Electric Strikes > 250MA (External Power Supply) ........................................................20
12 VDC Magnetic Locks UP TO 250MA (Internal Power Supply) ..................................21
12 VDC Magnetic Locks > 250Ma (External Power Supply) ..........................................22
AC Magnetic Locks (External Power Supply) ........................................................................23
Door Contacts ...............................................................................................................24
Exit Buttons...................................................................................................................24
Tamper/Forced, Door-Held-Open and Alarm-Shunt Outputs...............................................25
Tamper/Forced Entry Output (Shared outputs)..............................................................25
Door Held Open Output.................................................................................................26
Alarm Shunt Output.......................................................................................................26
Input Point Wiring (supervised)......................................................................................28

CP40 Page 4 of 43
Installation Manual October 2015 • Rev. 2.7
Input Point Wiring (nonsupervised)................................................................................29
Output Point Wiring .......................................................................................................29
Fire Release and Fire Reset Inputs........................................................................................30
Fire Alarm Release Input...............................................................................................30
Fire Alarm Reset Input...................................................................................................30
Communication Fail Output...................................................................................................31
SIOPT-16 Input/Output Board ................................................................................................32
Layout ...........................................................................................................................32
Installing the SIOPT-16 Input/Output Board...................................................................33
Input and Output Point Wiring........................................................................................34
SIOPT-16 Board Fire-Alarm Release ............................................................................35
Elevator ControL Using the SIOPT-16 Input/Output Board............................................36
Elevator Interface Board.........................................................................................................37
Troubleshooting......................................................................................................................39
Communication Problems..............................................................................................39
Reader Problems ..........................................................................................................40
Input/Output Board Problems........................................................................................41
Other Problems.............................................................................................................41
Appendix I ...............................................................................................................................42
RS-422 CLAUSB Wiring................................................................................................42
Magstripe Reader Connection.......................................................................................43
Copyright 2008 - 2015 Cansec Systems Ltd.
All rights reserved.

CP40 Page 5 of 43
Installation Manual October 2015 • Rev. 2.7
Supports 65,000 users
Supports 2 readers
Supports 26-bit or 37-bit Wiegand
Two onboard inputs and outputs
Up to 16 optional inputs and outputs
Supplies 12VDC power to DC Locks
250mA or less
Provides onboard relays
for external lock power control
Introduction
Maestro's CP40 control panel is the ultimate in reliable, cost-effective, and
comprehensive access management for up to 65,000 users. Each CP40
supports two readers, including the CanProx One Proximity Reader as well
as many other popular readers. CP40 control panels support either industry-
standard 26-bit Wiegand or Cansec's proprietary 37-bit Wiegand. Each board
supports two on-board inputs (supervised or nonsupervised), and two on-
board outputs.
For projects that require additional supervised point monitoring capacity, the
optional SIOPT-16 module can be added onto the CP40 at anytime to
provide 16 points, which can be individually configured as supervised inputs
or as outputs for facility monitoring and elevator control.
Key Features
NOTE: Tech Support will only be provided where product installation guidelines
have been followed.

CP40 Page 6 of 43
Installation Manual October 2015 • Rev. 2.7
Specifications
Power Requirements
CP40 Controller: ............................................ 16 VAC, 40 VA, 60 Hz
..............................................................or a 12 VDC/2A power supply
Current Draw
CP40
no readers/electric strikes .............................................................580 mA
with SIOPT-16 board or elevator interface board ............................900 mA
Locking Devices (electric strikes)/per 1 lock ...................250-300 maA
Temperature Range
Operating .......................................................................... 0˚C to 70˚C
Storage........................................................................... - 40˚C to 70˚C
Relative Humidity
Operating .......................................................................... 20% to 80%
Fuses
Main AC ........................................................................................... 3 A
Locks ................................................................................................ 1 A
Readers.........................................................................................0.75 A
Aux. 5 Volt.....................................................................................0.5 A
Battery .............................................................................................. 3 A
Output Relays
Lock (2 per panel) ...............................................SPDT 8 A @ 30 VDC
Communication Fail ..........................................SPDT 2 A @ 30 VDC
Alarm Shunt .......................................................SPDT 2 A @ 30 VDC
Door Held Open ................................................SPDT 2 A @ 30 VDC
Forced Entry (2 each per panel) ........................SPDT 2 A @ 30 VDC
I/O Board (outputs) ...........................................SPDT 2 A @ 30 VDC

CP40 Page 7 of 43
Installation Manual October 2015 • Rev. 2.7
Inputs
Door Contact (2 per panel) ...............requires normally closed contact
Exit Button (2 per panel)………………..requires normally open contact
...............................................................................................................
Communications and Reader Cable
RS-485 Cable ......................22 AWG, stranded/shielded, twisted pair
............................................................609 m [2000 ft] max total length
................................................................... Belden 88761 or equivalent
NOTE: Up to 16 controllers may be connected on an RS-485 bus.
Wiegand Readers ....................6 conductor (twisted pair not required)
.......................................................................... 22 AWG, overall shield
..................................................................... 152 m [500 ft]max. length
NOTE: consult reader specifications as 12-gauge wire may be required
for power.
Dimensions & Weight
CP40 Enclosure: .................... [33.3 cm (w) x 49.2 cm (h) x 9.2 cm (d)]
..................................................[13 1/8”(w) x 19 3/8”(h) x 3 5/8”(d)]
Weight..........................................................................8.4 kg [18.5 lbs]
*Specifications subject to change without notice.
IMPORTANT: In some jurisdictions, the use of a UL approved power
supply and connection to the fire alarm system for emergency release may
be required. Installers should contact the local authority having
jurisdiction to verify the specific requirements. Also, a building permit
may be required in some jurisdictions for the installation of magnetic
locks.

CP40 Page 8 of 43
Installation Manual October 2015 • Rev. 2.7
CP40 Controller Layout

CP40 Page 9 of 43
Installation Manual October 2015 • Rev. 2.7
Important Installation Notes
1. Any changes made to the settings (addressing, dip switches, etc.)
will take place only after the panel is RESET or power off and on.
2. Each controller must have a unique address.
3. Before connecting ANY wires (readers, communication, locks)
the lithium battery has to be Enabled and the panel has to be cleared.
See instructions below.
CA-PS123A Specifications Notice:
When using a pluggable 16 VAC standard 40 VA transformer:
Maximum Continuous Current (no battery attached): 2 amps for 12 VDC on
the Output.
Maximum Continuous Current (battery attached): 1.5 amps for 12 VDC on
the Output (battery will be charging when needed).
Using a wire in 16 VAC standard 75 VA transformer:
Maximum Continuous Current (no battery attached): 2.5 amps for 12 VDC
on the Output.
Maximum Continuous Current (battery attached): 2.0 amps for 12 VDC on
the Output (battery will be charging when needed).
Surge currents need to be taken into account. High current devices like
electric strikes and magnetic locks have surge currents which are usually
double the running current.
The CA-PS123A’s DC output is fused at 2.5 amps.
An electrician is not required for installation of this supply.

CP40 Page 10 of 43
Installation Manual October 2015 • Rev. 2.7
New Panel Installation Instructions
POWER UP THE PANEL
OR
NOTE: If battery is attached to on board charger (battery wires), the 16V
AC input will charge it, the 13.8V DC will not.
SET THE PANEL ADDRESS
Set the panel address by rotating the address
dial clockwise to the desired address from 1 to 16.
(A=10, B=11, C=12, D=13, E=14, F=15, 0=16)
DC Input
AC Input
Controller
Address = 1
16 V. Max
13.8 V. Max
Tabla de contenidos
Otros manuales de Controladores de Cansec

Cansec
Cansec SMARTLOCK Series Manual de usuario

Cansec
Cansec MAP2 Manual de usuario

Cansec
Cansec MAP1 Instrucciones de funcionamiento y mantenimiento

Cansec
Cansec H1000 Manual de usuario

Cansec
Cansec Canlan M200 Manual de usuario

Cansec
Cansec H1000 Manual de usuario

Cansec
Cansec MAPMINI Controller Manual de usuario

Cansec
Cansec Webster 64 Manual de usuario