Campbell CS451 Manual de usuario

CS451/CS456 Submersible
Pressure Transducer
Revision: 1/13
Copyright © 2009-2013
Campbell Scientific, Inc.


Warranty
“PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are
warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in
materials and workmanship under normal use and service for twelve (12)
months from date of shipment unless otherwise specified in the corresponding
Campbell pricelist or product manual. Products not manufactured, but that are
re-sold by Campbell, are warranted only to the limits extended by the original
manufacturer. Batteries, fine-wire thermocouples, desiccant, and other
consumables have no warranty. Campbell’s obligation under this warranty is
limited to repairing or replacing (at Campbell’s option) defective products,
which shall be the sole and exclusive remedy under this warranty. The
customer shall assume all costs of removing, reinstalling, and shipping
defective products to Campbell. Campbell will return such products by surface
carrier prepaid within the continental United States of America. To all other
locations, Campbell will return such products best way CIP (Port of Entry)
INCOTERM® 2010, prepaid. This warranty shall not apply to any products
which have been subjected to modification, misuse, neglect, improper service,
accidents of nature, or shipping damage. This warranty is in lieu of all other
warranties, expressed or implied. The warranty for installation services
performed by Campbell such as programming to customer specifications,
electrical connections to products manufactured by Campbell, and product
specific training, is part of Campbell’s product warranty. CAMPBELL
EXPRESSLY DISCLAIMS AND EXCLUDES ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. Campbell is not liable for any special, indirect,
incidental, and/or consequential damages.”

Assistance
Products may not be returned without prior authorization. The following
contact information is for US and international customers residing in countries
served by Campbell Scientific, Inc. directly. Affiliate companies handle
repairs for customers within their territories. Please visit
www.campbellsci.com to determine which Campbell Scientific company serves
your country.
To obtain a Returned Materials Authorization (RMA), contact CAMPBELL
SCIENTIFIC, INC., phone (435) 227-9000. After an applications engineer
determines the nature of the problem, an RMA number will be issued. Please
write this number clearly on the outside of the shipping container. Campbell
Scientific’s shipping address is:
CAMPBELL SCIENTIFIC, INC.
RMA#_____
815 West 1800 North
Logan, Utah 84321-1784
For all returns, the customer must fill out a “Statement of Product Cleanliness
and Decontamination” form and comply with the requirements specified in it.
The form is available from our web site at www.campbellsci.com/repair. A
completed form must be either emailed to repair@campbellsci.com or faxed to
(435) 227-9106. Campbell Scientific is unable to process any returns until we
receive this form. If the form is not received within three days of product
receipt or is incomplete, the product will be returned to the customer at the
customer’s expense. Campbell Scientific reserves the right to refuse service on
products that were exposed to contaminants that may cause health or safety
concerns for our employees.

Table of Contents
PDF viewers: These page numbers refer to the printed version of this document. Use the
PDF reader bookmarks tab for links to specific sections.
1. Introduction.................................................................1
2. Cautionary Statements...............................................1
3. Initial Inspection .........................................................1
4. Quickstart ....................................................................2
4.1 Step 1 — Desiccant Check...................................................................2
4.2 Step 2 — Choose Appropriate Depth...................................................2
4.3 Step 3 — Dislodge Bubbles .................................................................3
4.4 Step 4 — Install Transducer.................................................................3
4.5 Step 5 — Measure Initial Water Elevation...........................................3
4.6 Step 6 — Use SCWin to Program Datalogger and Generate
Wiring Diagram................................................................................4
5. Overview......................................................................6
6. Specifications .............................................................8
7. Operation...................................................................10
7.1 Configuration .....................................................................................10
7.1.1 PC Connection Using the A200 ..................................................10
7.1.1.1 Driver Installation ............................................................10
7.1.1.2 Wiring ..............................................................................10
7.1.1.3 Powering the Sensor.........................................................11
7.1.1.4 Determining which COM Port the A200 has been
Assigned .......................................................................11
7.1.2 Device Configuration Utility (version 2.03 or higher)................12
7.1.3 SDI-12 Transparent Mode ..........................................................12
7.1.4 RS-232 Connection via PC Terminal Software ..........................14
7.1.5 SDI-12 Commands......................................................................15
7.1.5.1 SDI-12 Addresses.............................................................16
7.1.5.2 Extended SDI-12 Commands...........................................17
7.2 Installation Considerations.................................................................18
7.2.1 Non-Vertical Installations ...........................................................18
7.2.2 Offset Calculation .......................................................................18
7.2.3 Split Mesh Cable Grip (pn 25431) ..............................................19
7.3 Wiring ................................................................................................19
7.3.1 SDI-12.........................................................................................20
7.3.2 RS-232 ........................................................................................20
i

Table of Contents
ii
7.4 Programming ..................................................................................... 20
7.4.1 CRBasic Programming............................................................... 21
7.4.1.1 Example Program for CR200(X)-Series Datalogger ....... 21
7.4.1.2 Example Program for CR1000 Datalogger..................... 22
7.4.2 Edlog Programming ................................................................... 22
7.4.2.1 Example Program for CR10(X) Dataloggers................... 23
8. Maintenance ..............................................................23
8.1 Every Visit......................................................................................... 24
8.2 Every Two to Three Years or on a Rotating Schedule ...................... 24
9. Troubleshooting........................................................24
Appendix
A. Calibration Certificate.............................................A-1
Figures
5-1. CS451 nose cone options..................................................................... 7
7-1. A200 Sensor-to-PC Interface............................................................. 11
7-2. Connect screen .................................................................................. 12
7-3. Terminal Emulator ............................................................................ 13
7-4. Terminal Emulator ............................................................................ 15
7-5. Transducer suspended with split mesh cable grip ............................. 19
Tables
7-1. Factory Settings................................................................................. 10
7-2. A200 Wiring...................................................................................... 11
7-3. RS-232 Settings................................................................................. 14
7-4. RS-232 Terminal Commands ............................................................ 15
7-5. SDI-12 Commands ............................................................................ 16
7-6. SDI-12 Wiring................................................................................... 20
7-7. RS-232 Wiring .................................................................................. 20

CS451/CS456 Submersible Pressure
Transducer
1. Introduction
The CS451/CS456 Submersible Pressure Transducer provides pressure and
temperature measurements. It uses the SDI-12 or RS-232 communications
protocols to communicate with an SDI-12 or RS-232 recorder simplifying
installation and programming. The -L in the transducer’s model name
indicates user-specified cable length.
Before using the CS451/CS456 please study
•Section 2, Cautionary Statements
•Section 3, Initial Inspection
•Section 4, Quickstart
2. Cautionary Statements
•Sensor will be damaged if it is encased in frozen liquid.
•Although the CS451/CS456 is rugged, it is also a highly precise scientific
instrument and should be handled as such. There are no user-serviceable
parts and any attempt to disassemble the device will void the warranty.
•Care should be taken when opening the package not to damage or cut the
cable jacket.
•Dropping the instrument or allowing it to “free fall” down a well may
damage the transducer.
•Never suspend the CS451/CS456 from the connections at the top end of
the cable. Sharp bends or excessive pinching of the cable can cause
damage and may pinch off the vent tube causing measurement errors.
•Confirm the compatibility of the sensor and cable to non-water
environments before installation.
•The CS456 should be used in harsh water applications, including salt
water.
3. Initial Inspection
•Upon receipt of the CS451/CS456, inspect the packaging for any signs of
shipping damage and, if found, report the damage to the carrier in
accordance with policy. The contents of the package should also be
inspected and a claim filed if any shipping related damage is discovered.
1

CS451/CS456 Submersible Pressure Transducer
•The model number and pressure range is etched on the housing and the
cable length is printed on the label near the connection end of the cable.
Check this information against the shipping documentation to ensure that
the expected product was received.
•The transducer comes with a desiccant tube attached to the cable.
4. Quickstart
This quickstart guide assumes:
•Default settings used (SDI-12 address 0, pressure reported in psig,
temperature reported in C)
•ShortCut Program Generator for Windows (SCWin) used to program
datalogger, calculate offset, and generate wiring diagram
For complete configuration, installation, wiring, and programming information,
see Section 7, Operation.
4.1 Step 1 — Desiccant Check
The desiccant tube is shipped with a black cap to cover the
vent hole. This cap MUST be removed prior to installation.
CAUTION
Ensure the desiccant is blue; replace if not.
The desiccant tube must always be attached to the CS451/CS456.
4.2 Step 2 — Choose Appropriate Depth
The CS451/CS456 must be installed below the water at a fixed depth. This
depth should be chosen so the water pressure will never exceed the
transducer’s pressure range (twice its pressure range).
The output reading will not be correct, and the transducer
can be damaged if pressure is excessive (2 x full scale).
CAUTION
Pressure can be converted to feet of fresh water using the following simple
equation:
1 psi = 2.31 feet of water
For example, the maximum depth with a pressure range of 0 to 7.25 psig is
16.748 feet of water.
2

CS451/CS456 Submersible Pressure Transducer
4.3 Step 3 — Dislodge Bubbles
While submersing the transducer, air bubbles may become trapped between the
pressure plate and the water surface, causing small offset errors until the
bubbles dissolve. Dislodge these bubbles by gently shaking the CS451/CS456
while under water.
If bubbles are not removed by rotation and shaking
underwater (or bleeding out the air in a closed system), the
CS451/CS456 reading will drift lower by the distance of the
gap as the bubbles are slowly dissolved into the water over
time.
CAUTION
Hitting against the well casing or other solid surface could
damage the transducer.
CAUTION
4.4 Step 4 — Install Transducer
Lower the transducer to an appropriate depth.
Do not drop the instrument or allow it to “free fall” down a
well as this may damage the sensor.
CAUTION
With long drops it may be necessary to use the weighted nose cone (option
-WN).
The transducer body can be strapped with tie wraps or tape. Campbell
Scientific offers cable ties (pn 7421) that can be used to secure and strain relief
the cable. If installing in a well, fasten the cable to the well head. Wrap the
cable ties around the cable jacket.
Never suspend the CS451/CS456 from the connections at
the top of the cable. Sharp bends or excessive pinching of
the cable can cause damage and may pinch off the vent
tube causing measurement errors.
CAUTION
Several readings should be taken to ensure proper operations after installation.
4.5 Step 5 — Measure Initial Water Elevation
Use a staff gauge (or other device) to measure the initial elevation of water.
This value is used to calculate an offset that corrects the final measurement for
errors due to zero offset or installation. SCWin will make the offset
calculation. Refer to Section 7.2.2, Offset Calculation, if not using SCWin to
calculate the offset.
3

CS451/CS456 Submersible Pressure Transducer
4.6 Step 6 — Use SCWin to Program Datalogger and Generate
Wiring Diagram
The simplest method for programming the datalogger to measure a
CS451/CS456 is to use SCWin.
1. Open Short Cut and click on New Program then select Next.
2. Select a datalogger and scan interval then select Next.
4
Otros manuales para CS451
4
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Transductor de Campbell
Manuales populares de Transductor de otras marcas

Mianyang Weibo Electronic
Mianyang Weibo Electronic WB Series Manual de usuario

ProMinent
ProMinent Dulcometer DMT Manual de usuario

MKS
MKS MicroPirani 925 Series Cómo utilizar

WIKA
WIKA WU-20 Manual de usuario

Alcatel Vacuum Technology
Alcatel Vacuum Technology BARATRON 622A Manual de usuario

Camille Bauer
Camille Bauer SIRAX CH-5610 Manual de usuario