PRODUCT SPECS
Main AC Supply: 110V AC, System Operating Voltage: 24V DC
Maximum Output Current: 30 amp, Fuse: 24V DC 30 Amp
Remote Control Distance: >150 Feet (50 meters)
Maximum Gate Weight: 1000 lbs
Maximum Gate Length: 18 Feet
Product Specs
LANGUAGES
To download this user manual in a different language, visit calimetco.com/manuals
Para descargar este manual de usuario en otro idioma, visite calimetco.com/manuals
WARNING
To reduce the risk of INJURY or DEATH:
•Never let children operate the gate or play around the gate. Keep the remote control away
from children.
•Always keep people and objects away from the gate. Cars, people, and other objects should
never enter when the gate is closing.
•Test gate operator monthly. The gate must reverse when it comes in contact with a solid
object, or stop when an object activates the non-contact sensors. After adjusting the force or
travel limit, re-test the gate operator. Failure to maintain the gate operator properly can
increase the risk of injury or death.
•Use the emergency release only when the gate is not moving.
•Keep the gate properly maintained. Read the owner's manual on how to maintain your gate.
Have a certified service technician make repairs or install gate operator hardware.
•The gate entrance should be used for vehicles only. Pedestrians should use a seperate entrance.
•Keep these instructions.
•Verify this operator is proper for the type and size of gate.
•Make sure the gate has been properly installed and slides freely in both directions. Repair
or replace all worn or damaged gate hardware prior to installation.

(OPTIONAL) Requirements for UL Compliant Installation
UL325 Installation
UL 325 standard is a safety standard for electric gate openers. If the gate operator installation
requires a UL325 installation, follow these instructions. For full instructions, visit the UL325
website.
Class I - Residential Locations & Class II - Commercial Locations / Multi-family housing
Slide Gates: Primary Device: A | Secondary Device (one required): B1, B2, D
Swing Gates: Primary Device: A, C | Secondary Device (one required) A, B1, B2, C, D
Class III - Industrial Locations / Limited Access Vehicular Gates
Slide Gates: Primary Device: A, B1, B2 | Secondary Device (one required): A, B1, B2, D, E
Swing Gates: Primary Device: A, B1, B2, C | Secondary Device (one required) A, B1, B2, D, E
Class IV- Guarded Industrial / Restricted Access Locations
Slide Gates: Primary Device: A, B1, B2, D | Secondary Device (one required): A, B1, B2, D, E
Swing Gates: Primary Device: A, B1, B2, C, D | Secondary Device (one required) A, B1, B2, C, D, E
REQUIRED ENTRAPMENT PROTECTION
A - Inherent (built-in) Entrapment protection System
B1 - Non-contact sensor such as a photo-eye or equivalent
B2 - Contact sensor such as edge sensor or equivalent
C - Inherent adjustable clutch or pressure relief device
D - Actuation device requiring continous pressure to maintain gate motion
E - Inherent Audio Alarm
NOTE: The same type of device shall not be utilized for both the primary and secondary entrapment
protection means. Use of a single device to cover both the opening and closing directions is in
accordance with the requirement; however, a single device is not required to cover both directions.
Class II - Commercial Locations / Multi-family housing
Slide Gates: Primary Device: A | Secondary Device (one required): B1, B2, D
Swing Gates: Primary Device: A, C | Secondary Device (one required) A, B1, B2, C, D
2

Additional UL Requirements
• A minimum of two (2) warning signs shall be installed, one on each side of the gate where easily visible.
• The gate must have sufficient room when opening and closing. Swinging gates should open inwards and
not into public access areas. The gate must be properly installed and move freely in both directions.
•Install the gate operator only when: 1) The operator is appropriate for the construction of the gate and
the usage Class of the gate, 2) All openings of a horizontal slide gate are guarded or screened from the
bottom of the gate to a minimum of 4 feet (1.2 m) above the ground to prevent a 2-1/4 inch (57.15 mm)
diameter sphere from passing through the openings anywhere in the gate, and in that portion of the
adjacent fence that the gate covers in the open position, 3) All exposed pinch points are eliminated or
guarded, and 4) Guarding is supplied for exposed rollers, could be UL approved
• The gate must be properly installed and work freely in both directions prior to the installation of the gate
operator. Do not over-tighten the operator clutch or pressure relief valve to compensate for a damaged
gate.
• For gate operators utilizing Type d protection: 1) The gate operator controls must be placed so that the
user has full view of the gate area when the gate is moving, 2) The placard as required by 52.1.1.6 shall be
placed adjacent to the controls, 3) An automatic closing device (such as a timer, loop sensor, or similar
device) shall not be employed, and 4) No other activation device shall be connected.
• Controls must be far enough from the gate (at least six feet) so that the user is prevented from coming
in contact with the gate while operating the controls. Controls intended to be used to reset an operator
after 2 sequential activations of the entrapment protection device or devices must be located in the line-
of-sight of the gate. Outdoor or easily accessible controls shall have a security feature to prevent
unauthorized use.
• For gate operators utilizing a non-contact sensor in accordance with 30A.1.1: 1) See instructions on the
placement of non-contact sensors for each Type of application, 2) Care shall be exercised to reduce the
risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and 3) One
or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as
the perimeter reachable by a moving gate or barrier.
• For a gate operator utilizing a contact sensor in accordance with 30A.1.1: 1) One or more contact sensors
shall be located at the leading edge, trailing edge, and post mounted both inside and outside of a
vehicular horizontal slide gate. 2) One or more contact sensors shall be located at the bottom edge of a
vehicular vertical lift gate. 3) One or more contact sensors shall be located at the pinch point of a
vehicular vertical pivot gate. 4) A hardwired contact sensor shall be located and its wiring arranged so that
the communication between the sensor and the gate operator is not subjected to mechanical damage. 5)
A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for
entrapment protection functions shall be located where the transmission of the signals are not obstructed
or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor
shall function under the intended end-use conditions.
(OPTIONAL) Requirements for UL Compliant Installation Continued
UL325 Installation
3

Installation
1. Lay out position of 6 wedge anchors by measuring clearance between anchors
and inside edge of gate. Figure 1
2. Install underground conduits in area for conduits. Figure 2 Wedge Anchor
Step 1: Installing the Base
The base, also known as a pad is a raised platform. We recommend using a concrete base.
1/2" x 3 1/2"
4
Contact local underground utility locating companies before digging more than 12 inches deep to
avoid damaging underground power, gas, or other utility lines.
Size of concrete base
A minimum of 2" on each side of the operator is recommended.

Step 2: Door arm installation
Figure 3
After you're satisfied with testing the arm in the full open and closed positions,
weld the following:
1. gate bracket to gate, 2. gate bracket to long arm, 3. short arm to gate opener metal bar.
Figure 4
A. Should be at least 1/4 the gate length. NOTE: Uphill or heavy gates should be at least 1/3 gate
length.
B. 14" minimum for open gate clearance (2" thick gate)
C. 27" distance
D&E. Arm should be 90° from gate when open and in the straight "locked". D=L*0.6, E=L*0.4
Installation
5

A. DO NOT allow the arm to touch the gate operator's hood when the gate is in the open
position. Too much stress is put on the arm in this position during gate operation.
Figure 6
A. Preferred arm position is 90° from the open gate.
B.
Distance between door and machine: 2" min
Installation
Figure 5
C.
6
NOTE: If dimension between open gate and wall is 20" to 32" then compact installation is
necessary. (See Figure 7)

Figure 7
Support bar should be installed at the gate bracket height across the entire gate to keep the
gate pickets from bending.
Installation
7

Figure 8
Figure 9
1. MUST use UL approved power wires, power wires MUST have minimum capacity for 15
amp current.
2. All operators MUST be properly grounded in order to prevent an electrical charge. Must
use a dedicated circuit for power supply.
3. When the power is connected, turn operator power switch to ON position.
Installation
8
Step 3: Connecting the Power

Step 4: Open Direction
Installation
9
See which direction your gate opens when viewed from the inside (exit side).
Dip Switch #6 (Figure 10) on the bottom of the gate operator circuit board
controls the open direction.
Figure 10
Step 5: Installing the Photo Eye
1. Plug the photo eye cable to the back of the gate opener,
behind the circuit board, Figure 11
2. Press the reset button on the gate operator control board.
3. Mount the photo eye on the stationary part of your gate or a post next
to your gate, about 21" from the ground.
4. Press the orange button on the photo eye to turn on the infrared beam.
5. Mount the reflector to the opposite side. Make sure the infrared beam hits
inside the circle of the reflector. Figure 12
6. Press the orange button on the photo eye to turn off the infrared beam.
Plug photo eye
cable here
Figure 11
Figure 12
Infrared beam
inside circle
Youtube
Youtube video with more details on how to install the photo eye: https://youtu.be/F7NpB9W_OMY
ON = opens to the right, OFF = opens to the left
Tabla de contenidos
Otros manuales de Abridor de puerta de Calimet

Calimet
Calimet CM-5-ACFP Manual de usuario

Calimet
Calimet CM9-975 Manual de usuario

Calimet
Calimet CM7-DCFP Manual de usuario

Calimet
Calimet CM6-ACFP Manual de usuario

Calimet
Calimet CM7-ACFP Manual de usuario

Calimet
Calimet CM-5-ACFP Manual de usuario

Calimet
Calimet CM3 Instrucciones de instalación

Calimet
Calimet CM3-ACFP Manual de usuario

Calimet
Calimet CM7-DCNB Manual de usuario

Calimet
Calimet CM6 Instrucciones de instalación