CAI Networks WebMux 480S Manual de usuario

i
Table of Contents
Table of Contents······························································································································ i
Packing List····································································································································iii
Main Components···························································································································· 1
Front View··································································································································· 1
Rear View···································································································································· 2
WebMux™ Overview······················································································································· 3
Key Features······························································································································· 3
The WebMux™ Family ··············································································································· 5
Network Overview······················································································································· 7
Sample Configurations···················································································································· 9
Single WebMux™························································································································ 9
Redundant Installation·············································································································· 11
Installation without IP Address Change··················································································· 13
Configuring the WebMux ·············································································································· 15
Before you Start ························································································································ 15
Hardware Setup --- Collect Information··················································································· 16
Hardware Setup ---Setup the new network ··············································································· 16
Hardware Setup ---Configuration Summary············································································· 17
Initial Configuration······················································································································ 17
NAT Mode Related Configuration ···························································································· 18
Out-of-Path Related Configuration··························································································· 20
NAT and Out-of-Path Common Configuration········································································· 20
What if I made mistake in my configuration? ··········································································· 23
Management Console···················································································································· 24
Login········································································································································· 24
Main Management Console ······································································································ 26
SSL Keys···································································································································· 27
Administration Set Up··············································································································· 33
Change Browser Login Password: ··························································································· 39
Set Clock:·································································································································· 41
Upload/Download····················································································································· 43
Add Farm ·································································································································· 44

ii
Modify Farm ····························································································································· 49
Add Server: ······························································································································· 51
Modify Server···························································································································· 54
Initial setup change Through Browser······················································································ 56
Initial Configuration Worksheets·································································································· 58
Sample Configuration Worksheets ································································································ 59
Contact Information······················································································································ 63
FAQs·············································································································································· 64
Regulations···································································································································· 67
Appendix 1 – How to Add A Loopback Adapter············································································ 68
Appendix 2 - How to make route delete reboot persistent····························································· 70
Appendix 3 - Phone Paging Codes································································································ 71
Appendix 4 – Virtual Hosting Issues····························································································· 73
Appendix 5 – Sample Custom CGI Code······················································································· 74
Appendix 6 – Access CLI Commands···························································································· 75
Appendix 7 – Extended Regular Expressions················································································ 76
Index·············································································································································· 77

iii
Packing List
•One (1) WebMux™ unit
•One (1) Power cord
•One (1) User Manual
•One (1) Warranty registration card

iv

The WebMux™ Model 480S, 580SG, and 680PG User Guide – Version 7.0.x
Copyright© 1997-2006 CAI Networks, Inc.
1
Main Components
Front View
Toggle Power Switch
This switch toggles power on and off. To power off, the switch must be pressed
and held for 5 seconds.
Reset Button
Press and release the reset button to reset the WebMux™. This process may
take several minutes to complete.
Up Arrow Button, Down Arrow Button
When each button is pressed, the value on the cursor location increases or
decreases. It goes through lower case letters, upper case letters, numbers and
symbols. When the cursor is located at the left most position on the LCD, the up
and down arrow allows the user to select a different item to setup.
Left Arrow Button and Right Arrow Button
When each button is pressed, the cursor moves to the left and right.
Check Mark Button, and Cross Button
Check Mark Button confirms the selection, Cross Button cancels the selection. At
any time when the system is running holding down to the Check Mark Button will
invoke the configuration menu, where you can change IP addresses and other
settings.

The WebMux™ Model 480S, 580SG, and 680PG User Guide – Version 7.0.x
Copyright© 1997-2006 CAI Networks, Inc.
2
Rear View
Server LAN Port
Connect this port to the Server LAN switch or hub. This port connects to the
servers and your local computers. It is the right most RJ45 socket. In Out-of Path
configuration, this is the only Ethernet cable to be connected.
Backup WebMux™ Port
Optionally, you may connect another WebMux™ to this port so that you can have
redundancy. If you have more than one WebMux™, you can connect them using
a cross over cable, or a regular cable with a hub.
Router LAN Port
Connect this port to the Router LAN switch or hub. In most situations, this port
connects to the Internet side network in NAT mode. It is the left most RJ45
Socket.
PLEASE NOTE: The Router LAN and Server LAN port are not interchangeable.
External Modem Connect Port
To utilize the phone pager function of the WebMux™, please connect the
external modem to this port. In some cases, if you prefer support engineers to
not use diagnostic ports over the Internet, our support engineers can also
connect through the modem to assist you with setup issues. A US Robotics
V.Everything modem is required: US Robotics part number 3CP3453. Modem dip
switch has 3, 8, and 10 down, rest up. A standard external modem cable is also
needed. Check with your modem supplier for the cable.
Power Switch
This switches the WebMux™ on and off. When in the "off" position, the front
panel power switch is disabled.
Power Cord
Please use the supplied power cord to connect the WebMux™ to the power
source. 1U WebMux™ has a 115V/230V AC universal power supply.

The WebMux™ Model 480S, 580SG, and 680PG User Guide – Version 7.0.x
Copyright© 1997-2006 CAI Networks, Inc.
3
WebMux™ Overview
Key Features
The WebMux™ is a standalone network appliance designed primarily to load
balance IP traffic to multiple servers. The WebMux™ includes the following key
features.
•Improves performance by distributing the traffic for a site or domain
among multiple servers. No one server will be bogged down trying to
service a particular site.
•SSL Termination to reduce the cost of multiple certificates.
•Provides high availability by tracking which servers are functioning
properly and which servers are out of service. If a server unexpectedly
goes down, the WebMux™ will automatically re-direct the traffic to other
servers, or will bring a standby or backup server online to service the
traffic. The WebMux™ does application level health check to many
network protocols on servers.
•Provides Persistent Connections by memorizing the user browser
session and the server session and sending the same user to the same
server. This is important for sites using shopping cart and dynamically
generated pages, like BroadVision, ASP and JSP sites.
•Provides fault tolerance. This installation requires two WebMuxes, a
primary and a secondary. The two WebMuxes will automatically sync the
configuration datum.
•Easy management. It can be managed via a secured web browser
session from anywhere in the world. By using https 128 bit encryption to
the management web console, secure remote management of server
farms is truly possible.
•Operating System independent. No software or agent to load on the
servers. Non-intrusive load/failure detection and management.
•Provides Proxy function. When communication is initiated from behind
the WebMux™, the WebMux™ will substitute its own address for the
internal address. This allows the web servers to initiate communication for

The WebMux™ Model 480S, 580SG, and 680PG User Guide – Version 7.0.x
Copyright© 1997-2006 CAI Networks, Inc.
4
services such as credit card validation and mapping services. (Note: this
function only works in NAT mode).
•Built-in Firewall Protections. Stop possible hacker intrusion into your
network from Internet. All IP addresses and ports are blocked except the
farm IP address. Built-in functions will detect any possible denial of service
attack and make your services always available. (Note: this function only
works in NAT mode with “Forwarding Deny”, see setup for details).
•In-Path or Out-of-Path Load Balancing. In normal setup, the WebMux™
can be configured In-Path, to act as firewall in addition to the load balancer
and health checker. However, if outbound traffic is much larger than
inbound traffic and you already have a firewall in place, or change of IP
address causes problems, consider using Out-of-Path configuration. Out-
of-Path load balancing is also called direct routing, or one leg operation.
•Layer 7 Load Balancing. WebMux™ can direct traffic to specific groups
of servers within a farm according to a match pattern in HTTP MIME
header. This allows you, for example, to group servers that serve only a
specific type of content while serving other types of content on another
group of servers. WebMux™ Layer 7 load balancing also includes URI
load directing with host name MIME header matching and cookies in order
to memorize the user browser session and the server session and send the
same user to the same server. This is important for sites using shopping
cart and dynamically generated pages.
•Informs you of the status of your network. It provides phone pager
and email notification so that the network administrator can be paged or
emailed whenever a server or WebMux™ goes down, and when it returns
online. This feature could reduce server room night shift operator costs, or
timely repair should the server goes down unexpectedly.

The WebMux™ Model 480S, 580SG, and 680PG User Guide – Version 7.0.x
Copyright© 1997-2006 CAI Networks, Inc.
5
The WebMux™ Family
The 1U WebMux™ family consists of three models. They are:
•The WebMux™ 480S
•The WebMux™ 580SG
•The WebMux™ 680SP
The table below compares the features of the models.
Model Number: 480S 580SG 680SP
Speeds:
Copper Ethernet Speed 10/100 10/100/1000 10/100/1000
MAX. SSL Termination 1024
RSA Transaction/S 120 200 2000
Max SSL Terminated connection 5,000 10,000 20,000
Max Active SSL Certificates 16 16 16
Balancing Method:
Round-Robin Yes Yes Yes
Persistent Round-Robin Yes Yes Yes
Weighted Round-robin Yes Yes Yes
Persistent Weighted Round-
robin Yes Yes Yes
Least Connections Yes Yes Yes
Persistent Least Connections Yes Yes Yes
Weighted Least Connections Yes Yes Yes
Persistent Weighted Least
Connections Yes Yes Yes
Weighted Fast Response Yes Yes Yes
Persistent Weighted Fast
Response Yes Yes Yes
Layer 7 URI load directing Yes Yes Yes
Layer 7 URI load directing with
host name MIME header
matching and cookies
Yes Yes Yes
Layer 7 hashed URI load
directing Yes Yes Yes
Fault Tolerance:
Diskless Design Yes Yes Yes
Port aggregation Yes Yes Yes
Failover via Ethernet Yes Yes Yes
Service aware Yes Yes Yes
Server aware Yes Yes Yes
Backup server Yes Yes Yes

The WebMux™ Model 480S, 580SG, and 680PG User Guide – Version 7.0.x
Copyright© 1997-2006 CAI Networks, Inc.
6
Performance:
Maximum concurrent
connections 1,440,000 2,880,000 5,760,000
Maximum New Connections/S 7,000 40,000 50,000
Maximum throughput per second 200 MBit/s 1 GBit/s 2 Gbit/s
Maximum Internet Link Speed 2 X T3 1.5 X OC-12 1.5 X OC-12
Management:
Secure web browser access Yes Yes Yes
In service/Not in service Yes Yes Yes
Page alarms (ext modem req) Yes Yes Yes
Email Notification Yes Yes Yes
Configuration access Yes Yes Yes
Remote telnet access Yes Yes Yes
Persistent connections Yes Yes Yes
Port mapping Yes Yes Yes
Port-specific services Yes Yes Yes
Security Features
Network Address Translation Yes Yes Yes
Network Port Translation Yes Yes Yes
TCP SYN protection Yes Yes Yes
TCP DoS protection Yes Yes Yes
SSL support Yes Yes Yes
Device Support:
Maximum virtual farms 500 Unlimited Unlimited
Maximum real servers 65,532 65,532 65,532
Device's role in the network IP router IP router IP router
UDP-based service support Yes Yes Yes
Misc.
Overnight Exchange Unit Service Contract ServiceContract ServiceContract
Free Email/Phone Support Three Years Three Years Three Years
Warranty on Hardware/Firmware Three Years Three Years Three Years
Power Consumption 120W 200W 350W
115VAC Current 2.5A 3.5A 5A
Heat Production 350BTU/H 550BTU/H 800BTU/H
Power and Cooling Requirement
95 – 130VAC or 195-235VAC at 50-60Hz universal input power required.
Absolute operating temperature range is 0-40C. Recommended operation
ambient temperature should not to exceed 30C.