Brink Flair 325 Guía de referencia

Flair 325 Enthalpy
English
Installation regulations


Installation regulations
Heat recovery appliance:
Flair 325 Enthalpy
Store near the appliance
This appliance may be used by children as of 8 years of age, persons with reduced
physical or mental capacities, and persons with limited knowledge and experience if
they are supervised or have received instructions on how to use the appliance safely
and are aware of the possible dangers.
Children younger than 3 years of age must be kept away from the appliance, unless
they are under constant supervision.
Children between the ages of 3 and 8 may only switch the appliance on or off, but only if
supervised or if they have received clear instructions on the safe use of the appliance
and understand the possible dangers, on the condition that the appliance has been
placed and installed in the normal position for use. Children between the ages of 3 and
8 may not insert the plug into the socket, nor clean or make changes to the settings of
the appliance, nor carry out any maintenance on the appliance that would normally be
carried out by the user. Children may not play with the appliance.
If you need a new power cable, always order the replacement from Brink Climate
Systems B.V. To prevent dangerous situations, a damaged mains connection must only
be replaced by a qualified expert!
Country: GB

Contents
1 Delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Delivery size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3 Version. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 Technical informaon. . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 Connecons and dimensions. . . . . . . . . . . . . . . . . . . 8
3.3 Exploded view of appliance. . . . . . . . . . . . . . . . . . . 10
4 Operaon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.1 Descripon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2 Bypass. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.3 Frost protecon. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.4 Oponal Plus pcb. . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5 Installaon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.1 Installaon general. . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.2 Placing the appliance. . . . . . . . . . . . . . . . . . . . . . . . 13
5.3 Connecng air ducts. . . . . . . . . . . . . . . . . . . . . . . . . 14
5.4 Electrical connecons. . . . . . . . . . . . . . . . . . . . . . . . 15
5.4.1 Connecng the power plug. . . . . . . . . . . . . . . 15
5.4.2 Connecng the mulple switch. . . . . . . . . . . 15
5.4.3 Connecng an eBus accessory. . . . . . . . . . . . 16
5.4.4 24 volt connecon. . . . . . . . . . . . . . . . . . . . . . 16
5.4.5 Connecng humidity sensor. . . . . . . . . . . . . . 16
5.4.6 Connecon internal Bus . . . . . . . . . . . . . . . . . 16
5.4.7 Connecng "signal output” connector. . . . . . 16
5.4.8 ModBus connecon. . . . . . . . . . . . . . . . . . . . . 16
5.4.9 Coupling appliances using internal Bus. . . . . 17
6 Display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6.1 General explanaon of control panel. . . . . . . . . . . 18
6.2 Display layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.3 Display informaon. . . . . . . . . . . . . . . . . . . . . . . . . 22
7 Starng appliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.1 Switching appliance on and o. . . . . . . . . . . . . . . . 23
7.2 Seng the air ow. . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.3 Other sengs for installer. . . . . . . . . . . . . . . . . . . . 24
7.4 Factory sengs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
8 Fault. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
8.1 Fault analysis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
8.2 Display Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
9 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
9.1 Cleaning lters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
9.2 Maintenance installer. . . . . . . . . . . . . . . . . . . . . . . . 29
10 Electrical diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
11 Electrical connecons accessories. . . . . . . . . . . . . . . . . 35
11.1 Connecng mulple switch. . . . . . . . . . . . . . . . . . 35
11.1.1 Connecng mulple switch with lter
indicaon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
11.1.2 Connecng wireless remote control (without
lter indicaon). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
11.1.3 Connecng extra mulple switch with lter
indicaon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
11.1.4 Connecng extra mulple switch with lter
indicaon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
11.2 Connecng Brink Air Control. . . . . . . . . . . . . . . . . 40
11.3 Connecng humidity sensor. . . . . . . . . . . . . . . . . 41
11.4 Connecng CO₂ sensor(s). . . . . . . . . . . . . . . . . . . . 42
11.5 Demand-driven venlaon 2.0. . . . . . . . . . . . . . . 43
11.6 Connecng postheater. . . . . . . . . . . . . . . . . . . . . . 44
11.7 Connecng preheater. . . . . . . . . . . . . . . . . . . . . . 45
11.8 Connecng Geo-heat exchanger. . . . . . . . . . . . . . 46
12 Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
12.1 Exploded view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
12.2 Service arcles. . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
13 Seng values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
13.1 Seng values standard appliance. . . . . . . . . . . . . 50
13.2 Seng values appliance with Plus pcb. . . . . . . . . 53
14 Conformity declaraon. . . . . . . . . . . . . . . . . . . . . . . . . . 55
15 ERP values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
16 Recycling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

1 Delivery
1.1 Delivery size
Before installation of the heat recovery appliance is started, check that it has been supplied in complete and
undamaged condition.
The delivery size of the heat recovery appliance type Flair 325 Enthalpy consists of the following components:
1. Heat recovery appliance1.
2. Wall mounting bracket consisting of:2.
▪1x mounting bracket▪
▪2 x protective caps▪
▪2x rubber strip▪
▪2x rubber rings▪
3. Documentation set consisting of:3.
▪1x installation instructions▪
▪1x occupant's instructions
▪
Flair 325 Enthalpy 615921-E Brink / 5

2 General
The Flair 325 Enthalpy is a ventilation unit with heat recovery for the balanced ventilation of dwellings.
Features:
▪Maximum capacity 325 m³/h▪
▪High efficiency heat exchanger▪
▪Filters ISO Coarse 60%▪
▪Modular electric preheater▪
▪Automatic bypass valve▪
▪Touchscreen▪
▪Adjustable air quantity▪
▪Filter indication on the appliance and the possibility of a filter indication on the multiple switch▪
▪An intelligent frost protection▪
▪Low sound level▪
▪Constant flow control▪
The Flair 325 Enthalpy is only available in one type:
▪the "Flair 325 Enthalpy"
▪
For the Flair 325 Enthalpy there is an optional Plus PCB available with more functions/ connection possibilities (>
Electrical diagram page 33).
These installation instructions describe both the standard Flair 325 Enthalpy and the Flair with Plus PCB.
The Flair 325 Enthalpy is available in Left-hand and Right-hand versions; it is not possible to convert the left and
right-hand models into one another.
For the correct connection ducts and dimensions (> Connections and dimensions page 8).
If you want to continue to ventilate in a balanced way at a temperature lower than -15°C, it is recommended to
use an extra preheater.
When the appliance is placed in an area where very cold outside air is expected for a long time (<-25°C), an extra
preheater (see ®Connecting preheater page 45 ) must always be installed!
The appliance comes ready to plug in with a 230 V mains plug.
Flair 325 Enthalpy 615921-E

3 Version
3.1 Technical information
Flair 325 Enthalpy
Supply voltage [V/Hz] 230V/50Hz
Dimensions (w x h x d) [mm] 750 x 650 x 560
Duct diameter [mm]ø ø 160
Weight [kg] 37
Filter class ISO Coarse 60% (ISO ePM1.0 for the air supply oponal)
Fan seng (factory seng) 0 1 2 3 max
Factory seng [m³/h] 50 100 150 250 325
Permissible resistance of duct system [Pa] 2 6 9 24 21 53 59 148 100 250
Rated power (excl. preheater) [W] 6.1 6.6 7.9 10.3 15.1 21.0 46.6 69.1 87.5 144.5
Rated current (excl. preheater) [A] 0.08 0.08 0.09 0.11 0.15 0.21 0.41 0.59 0.73 1.07
Max. rated current (incl. preheater switched on) [A] 6
Rated power preheater [W] 1000
Cos j0.341 0.343 0.389 0.394 0.430 0.439 0.492 0.507 0.521 0.542
Sound power
Venlaon capacity [m³/h] 100 150 150 200 200 250 325
Sound power level Lw(A) Stac pressure [Pa] 25 25 50 50 100 150 150
Casing radiaon [dB(A)] 27 34 35 40 41 46 51
Duct “From dwelling’
[db(A)] 32 40 38 46 44 49 55
Duct ‘To dwelling’ [db(A)] 44 49 51 55 57 62 69
*) Duct noise including end correcon
In pracce the value may dier by 1dB(A) through measurement tolerances.
Resistance
of duct
system
[Pa]
Note:
The stated value in
the circle is the
capacity (in Watt)
per fan
Flow rate [m3/h]
Flair 325 Enthalpy 615921-E Brink / 7

3.2 Connections and dimensions
The Flair appliance is available in a left-hand and right-hand version. With a left-hand version the “warm”
connections (from dwelling 3 and to dwelling 1) are on the left-hand side of the appliance; the condensate
discharge is then mounted at the right-hand opening below the appliance. With a right-hand version the “warm”
connections (1 & 3) are on the right-hand side of the appliance.
Left-hand version
All dimensions in millimeters. Diameter of all collars is 160 mm
1Supply air
2Exhaust air
3Extract
4Outdoor air
5Electrical connecons
6a Sealing cap
6b Sealing cap unused condensate discharge connecon; do not remove!
7Extract air lter
8Supply air lter
9Mounng bracket
Flair 325 Enthalpy 615921-E

Right-hand version
All dimensions in millimeters. Diameter of all collars is 160 mm
1Supply air
2Exhaust air
3Extract
4Outdoor air
5Electrical connecons
6a Sealing cap
6b Sealing cap unused condensate discharge connecon; do not remove!
7Extract air lter
8Supply air lter
9Mounng bracket
Flair 325 Enthalpy 615921-E Brink / 9

3.3 Exploded view of appliance
The appliance shown above is a le-hand version: in the case of a right-hand version, the connector of the preheater and bypass
valve are installed in mirror image!
1 Touchscreen 12 Enthalpy heat exchanger
2 USB connector (X13) 13 Motor bypass valve
3 Service connector 14 Discharge lter
4 LED indicator 15 Bypass valve
5 Maximum protecon preheater 16 Power cable 230 volt
6 Preheater 17 Relay output (X19) )
7 Temperature sensor 18 24 volt connector (X18)
8 Supply lter 19 eBus connector (X17)
9 Exhaust fan 20 24 volt connector (X16)
10 Sealing cap 21 Modbus/ internal bus connector (X15)
11 Supply venlator 22 Mulple switch connector (X14)
Flair 325 Enthalpy 615921-E