Brightwin Technology BRT2010 Manual de usuario

Temperature Calibrator
Users Manual
Model No.: BRT 2010
Shenzhen Brightwin Technology Co., Ltd.

Contents
1 Basic Introduction........................................................................................................ 1
1.1 Function............................................................................................................. 1
1.2 Summary of Source and Measure Functions...............................................1
1.3 Terminal Description.........................................................................................2
1.4 Key Description.................................................................................................3
1.5 Display Screen..................................................................................................4
2 Basic Operation............................................................................................................5
2.1 Measure and Source........................................................................................5
2.2 Shutdown Mode................................................................................................7
2.3 Backlight Brightness Adjustment....................................................................8
3 Function Usage............................................................................................................ 9
3.1 DC V Measurement..........................................................................................9
3.2 DC mV Measurement.................................................................................... 10
3.3 Resistance Measurement............................................................................. 10
3.4 DC mV Output.................................................................................................11
3.5 Resistance Output..........................................................................................12
4 Temperature Measurement......................................................................................13
4.1 Using Thermocouple (TC).............................................................................13
4.2 Using Resistance Thermometer Detector (RTD)...................................... 15
5 Simulation of temperature sensor........................................................................... 18
5.1 Simulating Thermocouples........................................................................... 18
5.2 Application of Resistance Temperature Detector (RTD).......................... 19
6 Advanced Application................................................................................................20
6.1 Setting 0 % and 100 % output parameters................................................ 20
6.2 Auto Ramping the Output..............................................................................21
6.3 Factory Reset..................................................................................................21
7 Power...........................................................................................................................22
7.1 Charge............................................................................................................. 22
8 Specifications............................................................................................................. 23
8.1 DC Voltage Measurement.............................................................................23

8.2 DC Voltage Source.........................................................................................23
8.3 Resistance Measurement............................................................................. 24
8.4 Resistance Output..........................................................................................24
8.5 Temperature, TC.............................................................................................25
8.6 Temperature, RTD..........................................................................................26
9 Product Accessories..................................................................................................27
9.1 Standard Accessories....................................................................................27
9.2 Optional accessories..................................................................................... 27
10 Warning.....................................................................................................................28

BRIGHTWIN BRT 2010 TEMPERATURE CALIBRATOR
www.brightwinelectronics.com info@brightwinelectronics.com 1
1 Basic Introduction
1.1 Function
It allows you to measure DC V, DC mV, resistance ,TC and RTD.
Outputs resistance, simulation of TC and RTD.
Thermocouple (TC) measurement provides cold-junction compensation.
Manual stepping, automatic stepping, 0 ~100% phase step and ramp
output.
Super-strong protection: The waterproof grade is IP67. Automatic
protection against the signal terminals connect to the 220V.
Support for PC communication
1.2 Summary of Source and Measure
Functions
Function
Measure
Source
DC V
0~30V
Not available
DC mV
0~120mV
0mV~100mV
Resistance
0~3200Ω
0~3200Ω
RTD
Pt100, Pt1000, Cu50,
Cu100
Pt100, Pt1000, Cu50, Cu100
TC
E,J,K,T,B,R,S,N
E,J,K,T,B,R,S,N
Others
Stepping output, ramp, phase step output, user-defined range

BRIGHTWIN BRT 2010 TEMPERATURE CALIBRATOR
www.brightwinelectronics.com info@brightwinelectronics.com 2
1.3 Terminal Description
Figure 1.3-1
No.
Name
Description
①
Communication and
charging connector
Connect power adaptor to charge batteries or connect
the calibrator to the computer.
②
3W and 4W terminal
3-wire and 4-wire electric and thermal resistance
measurement terminal.
③
COM Public terminal
terminal
All measurement and output public terminal.
④
V, mV, Ω,TC and RTD
terminal
Voltage and DC mV, 2-wire resistance,
thermal-electric and resistance measurement as well
as DC mV, resistance, thermocouple and
thermal-resistance output terminal.
⑤
4W+ terminal
Resistance and thermal resistance 4-wire
measurement terminal.

BRIGHTWIN BRT 2010 TEMPERATURE CALIBRATOR
www.brightwinelectronics.com info@brightwinelectronics.com 3
1.4 Key Description
Figure 1.4-1
No.
Description
①
Turns the power on or off
②
Selects the measurement mode
③
Selects output and analog transmitter mode.
④
Enables backlight switch display during start, enters backlight
brightness control mode.
⑤
Selects thermal resistance mode
⑥
Sets and saves calibrator parameters setting

BRIGHTWIN BRT 2010 TEMPERATURE CALIBRATOR
www.brightwinelectronics.com info@brightwinelectronics.com 4
⑦
Recovers factory default setting
⑧
Sets manual output
⑨
Cycles through:
slow repeating 0%-100%-0% ramp
Fast repeating 0 % - 100 % - 0 % ramp
Repeating 0 % - 100 % - 0 % ramp in 25 % steps
⑩
Set output by 0% of span, Press and hold to store the source
value as the 0 % value
⑾
Decrements output by 25% of span.
⑿
Increments output by 25% of span.
⒀
Sets output by 100% of span, Press and hold to store the
source value as the 100 % value.
⒁
Sets voltage, DC mV and resistance mode
⒂
Selects thermo-couple mode
1.5 Display Screen
Figure 1.5-1

BRIGHTWIN BRT 2010 TEMPERATURE CALIBRATOR
www.brightwinelectronics.com info@brightwinelectronics.com 5
2 Basic Operation
2.1 Measure and Source
This section acquaints you with some basic operations of BRT-2010/
BRT-1810.
Proceed as follows:
1. The connection of the calibrator as shown in Figure 2.1-1.
Figure 2.1-1
2. Press more than 2 seconds to turn on the calibrator. The calibrator
checks itself, including check on internal circuit and LCD, during which,
LCD displays all contents for 1s as shown in Figure 2.1-2:

BRIGHTWIN BRT 2010 TEMPERATURE CALIBRATOR
www.brightwinelectronics.com info@brightwinelectronics.com 6
Figure 2.1-2
3. Then the product model(2010)and automatic shutdown time(30 min)
will be displayed for 2 seconds as shown in Figure 2.1-3.
Figure 2.1-3
4. Then the default interface of boot will be displayed as shown in Figure
2.1-4:
Figure 2.1-4
5. Press , switch to the voltage mode. Switching is not required for this
series after starting-up.
6. Press to enter into output mode selection
7. Press to enter into DC mV output mode as shown in Figure 2.1-5.

BRIGHTWIN BRT 2010 TEMPERATURE CALIBRATOR
www.brightwinelectronics.com info@brightwinelectronics.com 7
Figure 2.1-5
8. Press and to increase or decrease 1 of the horizontal line
position (the number will be based on automatic stepping without change
of horizontal line position); press or to change the position of
horizontal line.
9. Press until the buzzer works and to enter 0mV as 0% value.
10. Likewise, press to increase output value to be 100mV, and then
press until the buzzer works and enter 100mV as 100% value.
11. Press or to make output increase or decrease within the
span of 0% to 100% based on 25% advance amplitude. The screen will
display as shown in Figure 2.1-6.
Figure 2.1-6
2.2 Shutdown Mode
The calibrator comes with the shutdown mode enabled for a time duration set to
30 minutes (displayed for about 2 seconds when the calibrator is initially turned
on). When the shutdown mode is enabled, the calibrator will automatically
Tabla de contenidos
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario