Brandywine IBU-240 Manual de usuario

MANUAL P/N 900000025 REV A
User Guide
IRIG Distribution Amplifier
Model IBU-240
P/N 019000001
Revision A
February 2006
Brandywine Communications
1153 Warner Avenue
Tustin, CA 92780
(714) 755 1050
(714) 755 0175
http://www.brandywinecomm.com

MANUAL P/N 900000025 REV A
2
Revision History
REVISION DATE COMMENT
NC 08-31-04 Original release of IBU-240 user guide.
A 02-20-06 Section 1.1.3 Fault/Status added.

MANUAL P/N 900000025 REV A
3
Safety Warnings
WARNING: This unit contains lethal AC voltages.
Disconnect the unit from the AC supply before removing
the cover.
WARNING:
The lightning flash with an arrowhead inside of an equilateral triangle is
intended to alert the user to the presence of un-insulated “dangerous
voltage” within the product’s enclosure. The “dangerous voltage” may be
of sufficient magnitude to constitute a risk of electrical shock to people.
CAUTION:
The exclamation point inside of an equilateral triangle is intended to alert
the user to the presence of important operation and maintenance
instructions in the user guide.

MANUAL P/N 900000025 REV A
4
Table of Contents
1Specifications.......................................................................................................................... 5
1.1 Inputs..................................................................................................................... 5
1.1.1 Time Code Input.................................................................................................... 5
1.1.2 Fault Discrete (Optional)........................................................................................ 5
1.1.3 Fault/Status ........................................................................................................... 5
1.2 Outputs.................................................................................................................. 5
1.2.1 Time Code Output ................................................................................................. 5
1.3 Switches and Indicators......................................................................................... 6
1.3.1 Status LED Indicators............................................................................................ 6
1.3.2 Environmental........................................................................................................ 6
1.3.3 Power..................................................................................................................... 6
1.3.4 Physical ................................................................................................................. 6
2Option Configuration Sheet..................................................................................................... 7
3Unpacking and Installation......................................................................................................8
3.1 Unpacking.............................................................................................................. 8
3.2 Installation.............................................................................................................. 9
3.3 Connections........................................................................................................... 9
3.3.1 Alarm Input Connection....................................................................................... 10
4Operation .............................................................................................................................. 11
4.1 Powering the IBU-240 ......................................................................................... 11
4.2 Selecting the Input Reference............................................................................. 11
4.3 Fault Indicator...................................................................................................... 12
5Maintenance and Troubleshooting ....................................................................................... 13
6Diagrams............................................................................................................................... 14

MANUAL P/N 900000025 REV A
5
1 Specifications
1.1 Inputs
1.1.1 Time Code Input
•Frequency: 300 Hz – 50 KHz
•Amplitude : 4 V
pp
•Input Impedance: 600 ohm
•Number of Inputs: 2 with auto selection and manual override from the
front panel toggle switch
•Connector Type: BNC
•Isolation: transformer coupled
1.1.2 Fault Discrete (Optional)
•Number of Inputs: 2
•Level: TTL
•Link selectable for active high or low
•Forces a changeover when active for on-line reference
1.1.3 Fault/Status
•Connector Type: DB-9 Female
•Mating Connector: AMP P/N 747904-2
1.2 Outputs
1.2.1 Time Code Output
•Number of Outputs: 24
•Connector Type: BNC
•Output Protection: short circuit proof
•Output Level: same as input
•Isolation: transformer coupled
•Output Impedance: 600 ohm

MANUAL P/N 900000025 REV A
6
1.3 Switches and Indicators
1.3.1 Status LED Indicators
•Power (Green)
•Reference Input A Available (Green)
•Reference Input A Online (Green)
•Reference Input B Available (Green)
•Reference Input B Online (Green)
•Automatic Reference Selection Selected (Green)
•Fault (Red)
1.3.2 Environmental
•Temperature:
oOperating: -30 to +60°C
oStorage: -40 to +85°C
•Humidity:
o10 – 95% non-condensing
1.3.3 Power
•115/230 VAC 50/60 Hz
•< 25 W
1.3.4 Physical
•Dimensions: 1.72” H x 14.5” D x 17.00” W and 1U 19” rack mount
•Weight: 7.5 lbs nominal

MANUAL P/N 900000025 REV A
7
2 Option Configuration Sheet
IBU-240 CONFIGURATION SHEET
PART NUMBER 019000001
CONNECTOR FUNCTION LEVEL INSTALLED
J1
ALARM INPUT
PIN 1 STATUS A
PIN 2 STATUS B
PIN 3 NO CONN
PIN 4 NO CONN
PIN 5 NO CONN
PIN 6 GROUND
PIN 7 GROUND
PIN 8 GROUND
PIN 9 NO CONN
ACTIVE H__L
b
ACTIVE H__L
b
b
J3 TIME CODE A INPUT 1.5 V
pp
b
J2 TIME CODE B INPUT 1.5 V
pp
b
J4 – J27 TIME CODE OUTPUT 1.5 V
pp
b
AC POWER 115 VAC
b

MANUAL P/N 900000025 REV A
8
3 Unpacking and Installation
3.1 Unpacking
Carefully remove the IBU-240 from the shipping carton. The following items
should be included in the shipment:
•1 IBU-240
•1 power cord
•1 user guide
Note the power entry module on the rear of the IBU-240 chassis. Please take
note of the voltage displayed on the rear of the power entry module and verify
that the voltage matches the local line’s voltage.
CAUTION:
THE IBU-240 WILL BE DAMAGED IF THE INCORRECT AC LINE
SETTING IS USED.
WARNING:
REMOVE THE POWER CORD FROM THE IBU-240 BEFORE
ADJUSTING THE LINE VOLTAGE.
If the AC line setting is incorrect, detach the power cord from the power entry
module. Use a small screwdriver to lift up the fuse cover on the power entry
module to remove the fuse holder. Reverse the fuse holder and re-insert the
fuse holder, making sure that the correct AC line voltage is now displayed on the
rear panel.

MANUAL P/N 900000025 REV A
9
3.2 Installation
The IBU-240 should be bolted directly into a 19” rack mount enclosure or
mounted on a shelf. The IBU-240 when fully populated has up to 27 cables
attached to the rear panel, therefore it is recommended that some appropriate
cable strain-relief system be used to support these cables, particularly when the
IBU-240 is not mounted on a shelf.
3.3 Connections
Insert the power cord provided in the shipment into the rear of the power entry
module. Connect the input reference signals to the appropriate connectors on
the rear panel.
CAUTION:
FOR CORRECT OPERATION, REFERENCE FREQUENCY A
AND REFERENCE FREQUENCY B MUST BE THE SAME
FREQUENCY, WHICH IS TYPICALLY 1 KHz.
Connect the output cables to the desired output connectors. Any unused
connectors may be left un-terminated.

MANUAL P/N 900000025 REV A
10
3.3.1 Alarm Input Connection
The IBU-240 may be used with an external reference such as the Brandywine
Communications GPS8 or PTS system that incorporates a discrete alarm signal.
This alarm signal is used to indicate that there is a fault (e.g. GPS not tracking)
on the reference signal even though the time code input signal may be present.
The factory standard IBU-240 configuration is a logic HI signal on the ALARM IN
pin indicates that the input is GOOD. A built in pull-up resistor ensures that if no
ALARM IN connection is made, the reference is still considered good. To
change the polarity of the ALARM IN, remove the top cover of the IBU-240 and
set the links to the link settings seen in the tables shown below.
LINK SETTING REFERENCE A STATUS
LK1 2-3 HI – reference A is GOOD
LK1 1-2 LO – reference A is GOOD
LINK SETTING REFERENCE B STATUS
LK2 2-3 HI – reference B is GOOD
LK2 1-2 LO – reference B is GOOD