B+K precision 6010 Manual de usuario

I
Before use
Thank you for your purchase of the Highspeed Programmable Attenuator model 6010/6011/6012/6013.
Please check the following prior to use of this equipment.
1. Ambient temperature and ventilation
The operating temperature of this equipment is 0°C to +40°C. Be careful not to obstruct air flow by
placing objects near the cover's ventilation hole and fan.
2. Power supply voltage
Check the power supply voltage before connecting the power cord of this equipment to a power outlet.
This equipment may be used with power supply voltage of 90 to 130V or 180 to 250V. The
equipment may fail if the power supply voltage is outside of these ranges.
3. Do not apply excessive voltage levels
Do not apply a voltage level exceeding ±20V to the TRIG IN input or READ CLOCK IN input.
4. Power cable
To avoid electric shock, use the provided power cable and connect it to a 3-prong power outlet.
5. Accessories
Please check that you received the following accessories:
1 Operating manual
1 Power cord
1 Fuse
1 Software Installation CD
1 RS-232C cable

II
Table of Contents
1.Overview 1
2.Specifications 2
2.1 Performance 2
2.2 External appearance and dimensions drawing 5
3.Description of panels 6
3.1 Front panel 6
3.2 Rear panel 8
4.Operation 9
4.1 Manual and program mode 9
4.2 ATTEN 9
4.3 FILTER 10
4.4 READ CLOCK 10
4.5 PRGM LENGTH 10
4.6 PAUSE TIME 11
4.7 READ MODE 12
4.8 SETUP 13
4.9 Set menu table 14
4.10 List of abbreviations 14
5.Attenuation profile creation software 15
5.1 System configuration 15
5.2 Installation and start-up 15
5.3 Menu structure 15
5.4 Operation 17
6.Remoteinterface 28
6.1 RS-232C protocol 28
6.2 GPIB protocol 29
6.3 Command list 30
6.3 Example program 31

1
1. Overview
The Highspeed Programmable Attenuator Models 6010/6011/6012/6013, the 6010 series, provide
attenuation of up to 80dB in steps of 0.05 dB and a minimum program step time of 2µs. The four models
cover a wide frequency range of 1.5GHz – 13.5GHz. The 6010 series offers high accuracy, stability and
many features, yet are easy to use. Due to the favorable price/performance ratio, the
6010/6011/6012/6013 attenuators are put to use in a diverse range of applications.
Features:
2 µs per word maximum switching speed (program readout clock speed) when in program mode
Wide attenuation range of 80dB for program and manual mode
Minimum attenuation step size of 0.05dB
Program run modes
The program can be executed in free run, burst, or gate mode.
FREE The program comprising of attenuation data and Pause information is
run continuously without the need of external trigger signals.
BURST Each rising edge of the trigger signal applied to TRIG IN triggers
execution of the program memory. Pause Time is ignored.
GATE The program (readout period) followed by the pause time is run while
the TRIG IN signal is TTL high.
Pause Time can be defined by number of clock cycles or by absolute time value
The Pause Time is the time interval in between program steps. It can be set in one-clock
increments or as a time value in 100 µs steps.
Software for creation of attenuation profiles
The 6010 series includes software to create and edit attenuation profiles and transfer the
attenuation data points via the RS-232C interface to the instrument’s internal memory (RS-232C
communication cable is included.) The Software is intuitive and Windows98/Me/2000/XP/Vista
compatible. The program’s large capacity and high resolution (memory depth of 128k words, 8 bits per
word) and support of clock frequency of up to 500 kHz makes the 6010 series an ideal tool for a broad
range of applications.

2
2. Specifications
2.1 Performance
Model 6010 Model 6011
Frequency range 1.5 to 4.5 GHz 3.0 to 9.0 GHz
VSWR < 1.5 @ 2 to 4 GHz
< 2.0 @ 1.5 to 4.5 GHz
< 1.7 @ 4 to 8 GHz
< 2.2 @ 3 to 9 GHz
Insertion loss
(0 dB setting)
< 2.3 dB @ 2 to 4 GHz
< 2.6 dB @ 1.5 to 4.5 GHz
< 3.0 dB @ 4 to 8 GHz
< 3.3 dB @ 3 to 9 GHz
Model 6012 Model 6013
Frequency range 4.5 to 13.5 GHz 1.95 to 5.85 GHz
VSWR < 1.8 @ 6 to 12 GHz
< 2.2 @ 4.5 to 13.5 GHz
< 1.6 @ 2.6 to 5.2 GHz
< 2.1 @ 1.95 to 5.85 GHz
Insertion loss
(0dB setting)
< 3.5 dB @ 6 to 12 GHz
< 3.8 dB @ 4.5 to 13.5 GHz
< 2.6 dB @ 2.6 to 5.2 GHz
< 2.9 dB @ 1.95 to 5.85 GHz
Attenuator
Setting range
Setting resolution
Accuracy
(at center of frequency range
and +10dBm input)
Impedance
Filter
Maximum input level
Input damage level
Input/output connectors
Readout clock input
Input level
Maximum frequency
Input impedance
Minimum pulse width
0 to 80 dB
0.05 dB
±0.5dB @ 0 to 10dB
±0.8dB @ >10 to 30dB
±1.0dB @ >30 to 50dB
±1.5dB @ >50 to 64dB
±2.0dB @ >64 to 74dB
±3.0dB @ >74 to 80dB
50 Ωnominal
1 µs to 3 ms, 1-3 step
100 mW, either CW or peak power
0.8W average power
20W peak power of 1 µs pulse
SMA
TTL
500 kHz
10 kΩ±5%
200 ns (for TTL low and high)
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
FAX 781.665.0780 - TestEquipmentDepot.com

3
Input damage level
Connector
Trigger input
Input level
Input impedance
Minimum pulse width
Input damage level
Connector
SYNC output
Output level
Rise / Fall time
Output impedance
Connector
±20V (DC + peak AC)
BNC
TTL
10 kΩ±5%
> 1 µs
±20V (DC + peak AC)
BNC
TTL
< 100ns
approximately 100 Ω
BNC
Functions
Attenuation mode
Program mode
Program length
Readout clock
Internal clock
External clock
Pause Time
Clock setting
Time setting
Program execution mode
Non volatile program memory
Manual and Program
8 to 131072 words, (can be set in one word steps)
100 Hz to 500 kHz, 1-2-5 step
DC to 500 kHz
0 to 65535 clocks adjustable in 1 clock cycle increments
0 to 6.5535sec (in 100µs increments)
Free, Burst, Gate
Program data is automatically saved when power is turned off.
Software for creating attenuation programs

4
Supported OS
Waveform creation
Standard waveforms
Parameters
Straight line
Math Functions
Editing options
File menu
Windows98/Me/2000/XP/Vista
Sine, Triangle, Square, Ramp, sin x/x, (1-ε-ax),
ε-ax and DC
Data length, Amplitude, Offset, Number of Cycles, Phase, Duty Cycle
(only Square wave), Zero cross (only sinX / X), Damp Factor
Connect two or multiple points with a straight line
+, -, ×, Clipping, Absolute, Mirror, Resize, Offset
Cut, Copy, Paste, Undo, Delete
New, Open, Close, Save, Save as, Data import,
Data export, Print, Printer setup, Transmit, Exit
Other
Display
Interface
RS-232C
Baudrate
GPIB
LCD (backlit. 2 rows of 20 characters)
Standard
2,400 to 57,600
Standard
General
Operating temperature
Operating humidity
Storage temperature
Power Supply
Weight
Dimensions
Standard accessories
0 to 40°C (Specifications guaranteed at 23 ±5°C)
less than 40°C / 80%RH (Guaranteed at less than 28°C / 80%RH)
-10 to +60°C / less than 80%RH
90 to 132VAC / 180 to 250VAC
(selectable by a switch located on rear panel)
approx. 10 lbs (4.5kg)
8.11” (W) ×4.53” (H) ×14.18”(D) (excluding projections)
260 (W) ×115 (H) ×360 (D) mm (excluding projections)
Operating manual (1pc), Power cord (1pc), Fuse (1pc),
Installation CD for creating attenuation profiles (1pc), RS-232C cable (1pc)

5
2.2 External appearance and dimensions drawing
Units in mm

6
3. Description of panels
3.1 Front panel
①POWER
- Main power switch.
②READ CLOCK IN
- READ CLOCK input terminal. Apply an external clock signal with a maximum of 500 kHz to this
input.
③TRIG IN
- Apply a TTL level trigger signal to this terminal when in BURST or GATE mode. Readout of
attenuation data is triggered by rising edge (BURST mode) or when signal is TTL high (GATE mode).
④SYNC OUT
- TTL level Output signal, indicates start of readout period when in program mode. The Sync signal is
programmable, see DLxxxx command in chapter 6 for details
⑤ATTEN IN/OUT
- Attenuator's input/output terminal.
⑥ATTEN OUT/IN
-Attenuator's output/input terminal.
CAUTION: Do NOT apply an input signal to both ATTEN IN/OUT terminals at the same time.
:⑦ATTEN MODE
- Key for selecting manual or program mode.

7
⑧READ CLOCK
- Key for selection of program memory read clock frequency.
⑨READ MODE
- Key for selecting BURST, GATE or FREE program execution mode.
⑩ATTEN
- Key for setting attenuation values in manual mode.
⑪PROGM LENGTH
- Key for setting the program memory length.
⑫SET UP
- Key for interface configuration.
⑬FILTER
- Key for setup of attenuator switching response time.
⑭PAUSE TIME
- Used for setting of program pause time.
⑮ENTER
- Used to confirm front panel entries
⑯
- Move cursor left.
⑰
- Move cursor right.
⑱ROTARY KNOB
- Increases or decreases the displayed numeric value. Turn clockwise to increase and
counterclockwise to decrease values.
⑲LIQUID CRYSTAL DISPLAY
- Letters can be displayed in two lines (up to 20 letters per line). The settings of all parameters such
as ATTN MODE, READ CLOCK, PROGM LENGTH, READ MODE and FILTER are displayed.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
FAX 781.665.0780 - TestEquipmentDepot.com
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Otros manuales de Unidad de control de B+K precision
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario