Bosch Security PoE midspans Manual de usuario

PoE midspans for PTZ cameras
en Installation Manual


PoE midspans for PTZ cameras Table of contents | en 3
Bosch Security Systems 2020-11 | 1.0 |
Table of contents
1Safety 4
1.1 About this Manual 4
1.2 Legal Information 4
1.3 Safety Precautions 5
1.4 Important Safety Instructions 6
1.5 Customer Support and Service 8
2Unpacking 9
2.1 Parts List 9
2.2 Parts List 9
2.3 Additional Parts Required 9
2.4 Tools Required 10
2.5 Additional Parts Recommended But Not Required 11
3System overview 12
4Installation (Indoor models) 13
5Installation (Outdoor model) 15
5.1 Installation overview 15
5.2 Connect the midspan to ground 16
5.3 Install the midspan directly to a wall 17
5.4 Install the midspan to a pole mount adapter 19
5.5 Connect the AC cable 24
5.6 Connect the RJ45 cable 25
6Connection 26
7Troubleshooting 29
8Disposal 33

4en | Safety PoE midspans for PTZ cameras
2020-11 | 1.0 | Bosch Security Systems
1 Safety
1.1 About this Manual
This manual has been compiled with great care and the
information it contains has been thoroughly verified. The text
was complete and correct at the time of printing. Because of the
ongoing development of products, the content of the manual
may change without notice. Bosch Security Systems accepts no
liability for damage resulting directly or indirectly from faults,
incompleteness, or discrepancies between the manual and the
product described.
1.2 Legal Information
Copyright
This manual is the intellectual property of Bosch Security
Systems, and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document
are likely to be registered trademarks and must be treated
accordingly.

PoE midspans for PTZ cameras Safety | en 5
Bosch Security Systems 2020-11 | 1.0 |
1.3 Safety Precautions
In this manual, the following symbols and notations are used to
draw attention to special situations:
Danger!
High risk: This symbol indicates an imminently hazardous
situation such as “Dangerous Voltage” inside the product. If not
avoided, this will result in an electrical shock, serious bodily
injury, or death.
!
Warning!
Medium risk: Indicates a potentially hazardous situation. If not
avoided, this may result in minor or moderate injury.
!
Caution!
Low risk: Indicates a potentially hazardous situation. If not
avoided, this may result in property damage or risk of damage
to the unit.
i
Notice!
This symbol indicates information or a company policy that
relates directly or indirectly to the safety of personnel or
protection of property.

6en | Safety PoE midspans for PTZ cameras
2020-11 | 1.0 | Bosch Security Systems
1.4 Important Safety Instructions
Important safety information
– The unit should be connected to PoE networks only,
without routing to the outside plant.
– Only qualified personnel can install or remove the unit.
– Follow basic electricity safety measures whenever
connecting the unit to its power source.
– A voltage mismatch can cause equipment damage and may
pose a fire hazard. If the voltage indicated on the label is
different from the power outlet voltage, do not connect the
unit to this power outlet.
– Read the installation instructions before connecting the
unit to its power source.
EMC compliance
– FCC Part 15 class B and EN 55022 class B
– EN55024
– VCCI
Safety compliance
– UL/cUL per 60950-1
– GS mark
– Installation and removal of the midspan must be carried out
by qualified personnel only.
– Follow basic electricity safety measures whenever
connecting the midspan to its power source.
– A voltage mismatch can cause equipment damage and may
pose a fire hazard. If the voltage indicated on the label is
different from the power outlet voltage, do not connect the
midspan to this power outlet.
– The PoE injector "Data In" and "Data & Power Out" ports
are shielded RJ45 data sockets. They cannot be used as
Plain Old Telephone Service (POTS) telephone sockets.
Only RJ45 data connectors can be connected to these
sockets.

PoE midspans for PTZ cameras Safety | en 7
Bosch Security Systems 2020-11 | 1.0 |
– The Data In and Data & Power Out interfaces are qualified
as SELV (Safety Extra-Low Voltage) circuits according to
IEC 60950-1. These interfaces can only be connected to
SELV interfaces on other equipment.
– This product is not intended to become a permanent part
of the building structure.
– Do not attach the power supply cord to the building
surface.
– Do not run the power supply cord through walls, ceilings,
floors, or similar openings in the building structure.
– Take appropriate measures to prevent physical damage to
the power supply cord, including proper routing.
– This device is not suitable for installation in corrosive
environments with salt water. Installers must make sure
that the installation location does not expose the device
housing directly to salt water.
– This device is not suitable for installation or operation in an
environment with SO₂.
For more information, refer to the installation manual, available
at http://www.boschsecurity.com/catalog_overview.htm

8en | Safety PoE midspans for PTZ cameras
2020-11 | 1.0 | Bosch Security Systems
1.5 Customer Support and Service
If this unit needs service, contact the nearest Bosch Security
Systems Service Center for authorization to return and shipping
instructions.
USA and Canada
Telephone: 800-289-0096, option 5
Fax: 800-366-1329
Email: [email protected]
Customer Service
Telephone: 800-289-0096, option 3
Fax: 800-315-0470
Email: [email protected]
Technical Support
Telephone: 800-289-0096, option 4
Fax: 800-315-0470
Email: [email protected]
Europe, Middle East, Africa, and Asia Pacific Regions
Please contact your local distributor or Bosch sales office. Use
this link:
https://www.boschsecurity.com/corporate/where-to-buy/
index.html
More Information
For more information, please contact the nearest Bosch Security
Systems location or visit www.boschsecurity.com.

PoE midspans for PTZ cameras Unpacking | en 9
Bosch Security Systems 2020-11 | 1.0 |
2 Unpacking
2.1 Parts List
The package containing the midspan should include the
following items:
Quantit
y
Component
1 60W midspan
1 120 V power cord
1 230 V power cord
1 Quick installation guide
Quantit
y
Component
1 High PoE Midspan 95 W, indoor model
1 120 VAC power plug
1 230 VAC power plug
1 Quick Installation Guide
Quantity Component
1 High PoE Midspan 95 W, outdoor model
1 120 -240 VAC power plug
2 Waterproof cap covers for male RJ45 port plugs
1 Quick Installation Guide
2.2 Parts List
2.3 Additional Parts Required
The following table lists additional parts (not supplied by
Bosch) required to install the midspan:

10 en | Unpacking PoE midspans for PTZ cameras
2020-11 | 1.0 | Bosch Security Systems
Quantity Part Size Notes
2 Mounting
screws;
Select either
size
(but not both).
Head diameter:
5.8 mm
(0.23 in.)
1.5 mm (0.059 in.)
clearance from mounting
surface
Head diameter:
7 mm
(0.27 in.)
Head height:
2 mm
(0.08 in.)
2.5 mm (0.098 in.)
clearance from mounting
surface
2 CAT5 cables Not to exceed
100 m (333 ft)
each
1 cable to connect to the
“Data & Power Out“
port.
1 cable to connect to the
“Data In” port.
Quantity Part Size Notes
4 Mounting
screws
2 CAT5 cables Not to exceed
100 m (333 ft)
each
1 cable to connect to the
“Data & Power Out“
port.
1 cable to connect to the
“Data In” port.
2 RJ45
connectors,
male
2.4 Tools Required
Screwdriver
Tabla de contenidos
Manuales populares de Sistema de seguridad de otras marcas

EDM
EDM Solution 6+6 Wireless-AE Manual de usuario

Highway Safety Group
Highway Safety Group EA401 Manual de usuario

Siren
Siren LED GSM Manual de usuario

Detection Systems
Detection Systems 7090i Instrucciones de montaje

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manual de usuario

Siemens
Siemens FDM273 Manual de usuario