BLAUBERG Ventilatoren inWave Manual de usuario

User’s manual
inWave
inWave EC
INLINE MIXED-FLOW FANS
EN

2
CONTENTS
Delivery set............................................................................................................................................................................................................................................. 9
Brief description .................................................................................................................................................................................................................................. 9
Operation guidelines ....................................................................................................................................................................................................................... 9
Designation key ................................................................................................................................................................................................................................. 10
Technical data....................................................................................................................................................................................................................................... 11
Mounting................................................................................................................................................................................................................................................. 12
Electronics operation algorithm ............................................................................................................................................................................................... 18
Technical maintenance................................................................................................................................................................................................................... 21
Troubleshooting.................................................................................................................................................................................................................................. 22
Storage and transportation regulations............................................................................................................................................................................... 23
Manufacturer’s warranty................................................................................................................................................................................................................ 24
This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the
inWave (EC) unit and all its modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should
be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the
territory of the country.

3
This unit is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the unit by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with
the unit.
This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and
understand the hazards involved.
Cleaning and user maintenance shall not be made by children
without supervision.
Children shall not play with the appliance.

4
Connection to the mains must be made through a disconnecting
device, which is integrated into the fixed wiring system in accordance
with the wiring rules for design of electrical units, and has a contact
separation in all poles that allows for full disconnection under
overvoltage category III conditions.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent, or similarly qualified persons in order
to avoid a safety hazard.
Ensure that the unit is switched off from the supply mains before
removing the guard.
Precautions must be taken to avoid the back-flow of gases into the
room from the open flue of gas or other fuel-burning appliances.
Do not attach the product to the support using glue or adhesives. Use
only the fastening method specified in the «User’s manual».

5
All operations described in this manual must be performed by
qualified personnel only, properly trained and qualified to install,
make electrical connections and maintain ventilation units.
Do not attempt to install the product, connect it to the mains, or
perform maintenance yourself.
This is unsafe and impossible without special knowledge.
Disconnect the power supply prior to any operations with the unit.
All user’s manual requirements as well as the provisions of all the
applicable local and national construction, electrical, and technical
norms and standards must be observed when installing and
operating the unit.
Disconnect the unit from the power supply prior to any connection,
servicing, maintenance, and repair operations.
Only qualied electricians with a work permit for electrical
units up to 1000 V are allowed for installation. The present user’s
manual should be carefully read before beginning works.
Check the unit for any visible damage of the impeller, the casing, and
the grille before starting installation. The casing internals must be free

6
of any foreign objects that can damage the impeller blades.
While mounting the unit, avoid compression of the casing!
Deformation of the casing may result in motor jam and excessive
noise.
Misuse of the unit and any unauthorised modifications are not
allowed.
Do not expose the unit to adverse atmospheric agents (rain, sun, etc.).
Transported air must not contain any dust or other solid impurities,
sticky substances, or fibrous materials.
Do not use the unit in a hazardous or explosive environment
containing spirits, gasoline, insecticides, etc.
Do not close or block the intake or extract vents in order to ensure the
efficient air flow.
Do not sit on the unit and do not put objects on it.
The information in this user’s manual was correct at the time of the
document’s preparation.
The Company reserves the right to modify the technical
characteristics, design, or configuration of its products at any time in

7
order to incorporate the latest technological developments.
Never touch the unit with wet or damp hands.
Never touch the unit when barefoot.
BEFORE INSTALLING ADDITIONAL EXTERNAL DEVICES, READ THE
RELEVANT USER MANUALS.
THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.
DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE

8
H
M
inWave (EC) 100/125 (spigot ø100 mm)
D
D
D
L
L
L
inWave (EC) 100/125 (spigot ø125 mm)
D
D
D
L
L
L
inWave (EC) 150 (spigot ø150 mm)
inWave (EC) 160 (spigot ø150 mm with a rubber seal)
D
D
D
L
L
L
Ø D L B H M
inWave (EC) 100/125
100 752
253 273 148
125 679
inWave (EC) 150 150 606
160

9
OPERATION GUIDELINES
The fan is rated for connection to single-phase AC 220-240 V/50 Hz power mains.
The fan is rated for continuous operation.
Air motion direction in the system must match the pointer on the fan casing.
According to the type of protection against electric shock, the Stream product belongs to class II devices,
Stream EC - to class I.
Ingress protection rating against access to hazardous parts and water ingress is IPХ4.
The fan is rated for operation at the ambient temperature ranging from +1 °C up to +40 °C.
DELIVERY SET
Fan – 1 pc.
Screws and dowels – 4 pcs.
User’s manual – 1 pc.
Packing box – 1 pc.
Rubber seal (for the inWave 150/160 model) – 2 pcs.
BRIEF DESCRIPTION
The product described herein is a mixed-flow inline fan for supply or extract ventilation of premises.
The fan is connected to the ø 100, 125, 150 and 160 mm air ducts.

10
DESIGNATION KEY
inWave EC 150 US
Options:
T: timer;
G1: speed controller with an electronic thermostat and an outdoor temperature sensor
fixed on a 4 m cable. Equipped with a power cord with a mains plug.
Temperature-based operation logic;
GT1: speed controller with an electronic thermostat and external temperature sensor fixed
on a 4 m cable. Equipped with a power cord with a mains plug.
Timer-based operation logic;
GS1: speed controller with an electronic thermostat and an outdoor temperature sensor
fixed on a 4 m cable. Equipped with a power cord with a mains plug.
Temperature-based switching on/off;
FR1: smooth speed controller from 0 to 100 % and power cord with a mains plug;
W: power cord with mains plug;
US: speed switch.
Spigot diameter [mm]
Electric motor type
_: asynchronous
EC: electronically commutated
Inline mixed-ow fan