C59501186 | 01 | 07.2017 | 20659EE | Designed in Germany
TÜRTECHNIK | DOOR TECHNOLOGY
I/O module for SECUREconnect 200
B-54900-03-3-8
Aimed at trained door specialists with knowledge of installing lock and hardware components, these instructions provide information
on how to install, commission and operate this product.
Please read these instructions carefully before installation and commissioning!
The necessity to observe the instructions given in this manual must be pointed out to building contractors and users in order to prevent
false installation and improper usage. Therefore, this manual must be delivered to building contractors and end users.
The appropriate local installation specifications, directives and regulations must be followed. This applies especially to the
VDE directives and regulations, e.g., DIN VDE 0100 and IEC 60364.
No liability is assumed for damage arising from improper use, assembly and installation, and from use of non-original parts and
accessories!
For safety and product approval (CE) reasons, the product must not be converted or modified.
Before starting any installation, repair, maintenance or adjustment work, ensure that no voltage is applied to any of the power
supply units and protect against unintended switch-on.
Claims made under the warranty for damage caused by non-observance of these instructions will become invalid! No liability is
assumed for consequential damage!
Technical data
General description The I/O module serves to transfer signals from a lock connected to the SECUREconnect 200 via
secure data transfer (bus connection). The outputs at the I/O module can be used to map all lock
functions. The inputs provide for execution of the control functions (short-time open, permanent
open and locking) of the SECUREconnect.
Dimensions 92.5 x 92.5 x 53 mm
Supply voltage 12...24 V DC
Current consumption (at 24 V
DC)
< 100 mA
Switching capacity of relay: 1 A/30 V DC
Environmental conditions °C
-20 °C
+55 °C
IP65
Max. length of door bus 20 m
Pairing In order to establish an encrypted connection, the SECUREconnect needs to be paired
with the I/O module.
On first commissioning, pairing starts in both components automatically.
If the SECUREconnect in a paired combination is replaced, the I/O module
connects automatically to the new SECUREconnect.
If the I/O module is replaced, pairing must be started via the SECUREconnect.
Certifications