Bentel Security OmniaMOD-V2 Guía


Contents in this manual may be subject to change without notice and does not represent any
obligation behalf of BENTEL SECURITY srl.
via Florida - Z.I. Valtesino - 63013 GROTTAMMARE (AP) - ITALY
Installation and use manual: Central Station OmniaMOD-V2

TABLE OF CONTENTS
TABLE OF CONTENTS 3
INTRODUCTION 5
General description . . . . . . . . . . . . . . . . . . . . 6
System requirements and description . . . . . . . . . . 6
OmniaMOD-V2 modem 7
General features . . . . . . . . . . . . . . . . . . . . . . 7
General description . . . . . . . . . . . . . . . . . . . . 7
Parts identification . . . . . . . . . . . . . . . . . . . . . 8
Installation . . . . . . . . . . . . . . . . . . . . . . . . . 8
LED description . . . . . . . . . . . . . . . . . . . . . 10
CENTRAL STATION program 11
Software installation . . . . . . . . . . . . . . . . . . . 11
Program startup . . . . . . . . . . . . . . . . . . . . . 12
Quit Program . . . . . . . . . . . . . . . . . . . . . . . 12
Central Station working principle . . . . . . . . . . . 13
Event printout . . . . . . . . . . . . . . . . . . . . . . 14
Settings . . . . . . . . . . . . . . . . . . . . . . . . . . 14
TABLE OF CONTENTS 3

Customer Data . . . . . . . . . . . . . . . . . . . . . . 15
Events . . . . . . . . . . . . . . . . . . . . . . . . . 15
New pictures . . . . . . . . . . . . . . . . . . . . . . 16
New icons . . . . . . . . . . . . . . . . . . . . . . . . 16
Time link . . . . . . . . . . . . . . . . . . . . . . . . 16
Test . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Map . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Operator Data . . . . . . . . . . . . . . . . . . . . . . 19
Printers . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Colours . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Central Station . . . . . . . . . . . . . . . . . . . . . . 19
Modems Setup . . . . . . . . . . . . . . . . . . . . . 20
Global Setup . . . . . . . . . . . . . . . . . . . . . . 20
Printing reports . . . . . . . . . . . . . . . . . . . . . 21
How to . . . . . . . . . . . . . . . . . . . . . . . . . . 23
IMPORT DATA program 25
4Central Station OmniaMOD-V2

INTRODUCTION
ATTENTION This manual describes the use of the OmniaMOD-V2 in se-
curity systems, however, it is possible to use it for the remote control, via
telephone, of all types of systems that can transmit data with the ADEMCO
protocol (for example, the Bentel MD-COM digital communicator).
The OmniaMOD-V2 Central Station is a main control unit which receives
information, via telephone, from remote security-systems. OmniaMod-V2
consists of:
ØMS-DOS personal computer (not supplied);
Øfrom 1 to 4 OmniaMOD-V2 modems (one modem supplied);
ØCentral Station and Import Data programs;
Øup to two printers (not supplied).
The Central Station permits:
rreception of coded events from remote security systems;
ridentification of the type of event and location, by means of the client data-
base stored in the computer;
rgraphic presentation - map of the city;
rgraphic presentation of the event on the map, shown by the flashing of the
icon assigned to the client;
rfull archiving on the hard disk, of all events and operator actions;
rsequential printing of all events;
revent analysis according to selected filters;
rarchive printout according to selected filters;
rmultilayer password access;
revent reception even when the operator is not logged in;
rthe possibility to control up to 4 telephone lines (with 4 OmniaMOD-V2 mo-
dems and a PC with 4 serial ports);
revent reception from different types of control panels (Bentel, DSC, etc.);
ronline help.
INTRODUCTION 5

General description
The OmniaMOD-V2 central station receives events from remote security sys-
tems. A remote security system consists of a control panel with built-in digital
communicator. Data from the control panel is sent via telephone to the Om-
niaMOD-V2 modem, which then sends it to the computer. Event data that is
received by the modem is interpreted by the Central Station software, accord-
ing to the client data:
Øclient address;
Øtelephone number;
Øsystem pictures and ground plans;
Øsensor position on the premises;
Ødiagram of arm/disarm times of the remote security system.
Each event which occurs in the remote system causes the communicator
to send coded data to the OmniaMOD-V2. When the event is acknow-
ledged, it is displayed on the monitor (and also printed on the printer) ac-
cording to its priority. Events are classified in three groups:
Øalarms (an event is acknowledged by an acoustic signal and flashing of
the message in the active window);
Øwarnings (also generate the acoustic signal and message in the active
window);
Ømessages give the rest of the information which tells the operator of the
status of the remote systems, and of the Central Station itself (arm/disarm,
test communications, operator change-over, ...).
When an alarm or warning occurs, the operator, according to instructions, scans
the system information and pictures, then takes the necessary actions to elimi-
nate the cause of the event (calls the fire brigade, sends a security team to the
system location, sends maintenance service to the system location).
System requirements and description
Computer
rCPU i80486 or higher.
r4Mb of RAM.
rAt least 10 Mb free on the hard disk.
rMS-DOS 3.3 or higher
rPrinter.
Telephone lines Public telephone network or local telephone network with equivalent char-
acteristics.
Modem BENTEL OmniaMOD-V2.
remote security
system Built-in communicator with the capability of sending data in ADEMCO pro-
tocol 10 baud in required data format 3+1, 3+2, 4+1, 4+2.
6Central Station OmniaMOD-V2

OmniaMOD-V2 modem
ATTENTION For proper interaction with the Central Station, the Mo-
dem must be programmed according to the instructions in the "Mo-
dems Setup" paragraph.
The OmniaMOD-V2 modem can perform teleservice (programming,
control, status change, receive test calls) from the BENTEL Omnia and
NormaCom (for further details see the respective manuals).
General features
rCommunication protocols: ADEMCO 10 baud in format 3+1, 3+2, 4+1, 4+2.
r256 event memory.
rRS232 Serial Port.
rPower supply:
external power supply adapter, input 230 V 50 Hz, output 18 V 150 mA.
rHousing for 12 V 1.2 Ah max. battery.
rDimensions W x D x H: 176 x 131 x 65 mm.
General description
The OmniaMOD-V2 is designed for telecontrol (the control of security sys-
tems via telephone). In fact, as well as recognizing the ADEMCO protocol,
it houses a 12 V 1.2 Ah max. battery (not supplied), that guarantees func-
tioning during blackout. The OmniaMOD-V2 event memory (up to 256
events) avoids data loss during communication problems with the control
program (for example, when the program is not running or is busy commu-
nicating with another modem or when the PC is not operating, due to
blackout).
+When the modem is receiving an incoming call from a security system, it
cannot answer calls coming from other systems, due to the engaged status
of the telephone line. Therefore, avoid making several calls at the same
time (it is advisable to program different times for security system test
calls) or program a higher number of call attempts or send calls to several
telephone numbers.
In order to have these possibilities the Central Station must have several
telephone lines, each of which connected to an OmniaMOD-V2 modem.
Each modem must be connected to a serial port of the PC. This is possible
with the Central Station program, which can manage up to 4 modems.
OmniaMOD-V2 modem 7

Part identification
The numbers in boldface in the manual, if not stated otherwise, refer to the
parts indicated in the diagram on page 9. The parts are described in the
following table.
PARTS DESCRIPTION
1Screws (4).
2ON/OFF switch.
3Battery connectors.
4Jack plug for external power supply.
5Connector for the PC serial port.
6Connector for the telephone line.
7Connector for line-sharing devices (telephone, fax, etc.).
8Serial cable for modem connection to the PC.
9External power supply adapter.
10 Battery housing for 12 V 1.2 Ah max. (battery not supplied).
Installation
For proper installation of the modem, see the diagram on the opposite
page and follow the instructions below.
ARemove the screws 1and cover from the modem.
BCheck that switch 2is on "0" (modem OFF), put the 12 V 1.2 Ah battery
(not supplied) in position 10 and connect it to the connectors 3taking care
not to invert the polarity.
CClose the modem.
DConnect the external power adapter 9to the modem connector 4and a
power socket (230 V 50 Hz), the LED lights.
EConnect the modem connector 5to a serial port on the PC by means of
the serial cable 8.
+The serial port used for connection to the modem must be specified in the
Central Station program (see "Modems Setup").
FConnect the modem connector 6to the telephone line.
+The modem must be connected to the telephone line, before any other
line-sharing devices.
GConnect any line-sharing devices to the modem connector 7.
+When the modem engages the line, all the devices connected to the line
are bypassed.
8Central Station OmniaMOD-V2

Figure 1 Parts identification and installation of the OmniaMOD-V2 modem.

LED description
The following table shows the meaning of the LEDs on the front of the mo-
dem. The normal condition is shown first (in boldface), followed by the
meaning of status change.
LED DESCRIPTION
Normally OFF. When ON, it indicates that there is at least one event in
the logger.
Normally OFF. This LED goes ON during data transfer between the
modem, and the panel that is connected via telephone.
Normally OFF. When ON, indicates that the modem has engaged the
telephone line, bypassing all other line-sharing devices.
Normally OFF. This LED goes ON with the first ring of the incoming call.
Normally ON. When OFF, it indicates that the modem is OFF.
Normally ON. When OFF, it indicates external power failure.
10 Central Station OmniaMOD-V2
Tabla de contenidos
Otros manuales de Unidad de control de Bentel Security

Bentel Security
Bentel Security KYO 4 M Manual de usuario

Bentel Security
Bentel Security KYO 4 M Manual de usuario

Bentel Security
Bentel Security Absoluta ABS-IP Guía del usuario

Bentel Security
Bentel Security FireClass FC500PSTN Manual de usuario

Bentel Security
Bentel Security FC430SAM Manual de usuario
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario