QUICK GUIDE
Entering an Administrator PIN*:
1. Press any key to activate the keyboard.
2. Type 123456 [default password], followed by #.
3. Press key 2 (2 beeps followed by a pause).
4. Type the Administrator PIN you want to insert (1 to 9 digits),
followed by # (3 beeps followed by a pause)
5. Type 2 for ARC-type receiving devices (or 1 for HCS or 3 for
fixed code).
6. The device emits 2 beeps and exits programming. The Ad-
ministrator PIN is registered in the memory.
Sending the stored code:
7. Press any key to activate the keyboard.
8. Type the previously stored Administrator PIN, followed by #.
9. 2 beeps and two flashes of the green central LED signal the
successful radio transmission of the PIN.
*IMPORTANT:
This procedure stores a numerical code to be sent to the radio receiver.
Subsequently, it is necessary to memorize this numerical code in the radio
receiver, following the indications in the specific instructions.
We recommend that you personalize the device password, write down the
password and KEEP IT IN A SAFE PLACE for future maintenance.
The device is compatible with the different types of the Benincà receivers;
the type of encoding used by the numerical code is established in point
5 of the insertion procedure. Different codes may use different types of
encoding.
EN

8
5
3
1
7
9
*
6
4
2
8
0
#
ENTER
LED
133 mm
29 mm 85 mm
1
50
70
Ø 5
V
T
H

9
2
G

10
3
G

11
4
- +
3,6V
1/2AA
Y
3,5x10mm TORX
5
m

20
1) IRI.KPAD
1.1) DESCRIPTION
Programmable wireless digital keypad.
It allows to carry out the control of automatic systems for gates and similar systems,
with no need to lay any cables.
IRI.KPAD is powered by one 3,6V 1/2 AA battery and transmits the radiofrequency
control to another transmitter in a similar way. The main characteristics are:
• LED retro light.
• Compatible with all Benincà radio receiver models with 433.92 MHz operating
frequency.
• Type of code: programmable code,rolling- code andARC (advanced rolling-code).
• 1 to 9 digit code composition.
• 0 to 9 keys plus #or to confirm.
• Possible setting of access password,scalar code and elimination of single codes.
• Possible enabling of the # key for code repetition.
• Indication of down battery and buzzer for acoustic indications.
1.2) TECHNICAL DATA
Power supply One 3,6V 1/2AA lithium battery (Li) 1400 mAh
Range without obstacles
100m
Operating frequency 433,92 MHz
Operating temperature -20°C / +70°C
Number of storable codes
254
Protection level IP55
Overall dimensions see Fig.1
1.3) WALL INSTALLATION (FIG. 1)
WARNING:As the various programming phases require an access to the radio receiver of
the system,it is advisable to fix the keypad to wall only after programming all functions.
The IP55 protection level permits to use the keypad also on walls that are not
protected against weather agents.
It is however advisable, whenever possible,to apply the system on a protected wall.
In any case, it is mandatory to apply the G gasket between wall and container.
(FIG.2-3)
1. Open the container by loosening the screw H.Screw H is a 3.5 mm TORX security
screw, supplied with a special screwdriver.
2. Apply the bottom of the container to wall by using either the two plugs T and
the two screws C, if a masonry support is provided, or self-tapering screws, if
a metal support of provided: in any case, use a fixing suitable to the support.
3. Close the container.

21
Note: The central part of the keypad can be removed to leave the underlying part
visible. In this case, remove the center part of the gasket and apply it to the support
after removing the central cover (Fig.2).
Otherwise, leave the cover in place, and apply the entire adhesive gasket (Fig. 3).
1.4) HOW TO REPLACE THE BATTERIES (FIG. 4)
IRI.KPAD is supplied with a 3.6V 1/2 AA battery that is not inserted, in order to
preserve battery life.
To insert the battery (or replace it when it is dead), proceed as follows:
Open the container by removing the screw H, Fig.2. Screw H is a 3.5 mm TORX
security screw (fig.5),supplied with a special screwdriver.A battery removable cover
is supplied on the rear part, fixed with the two screws Y, Fig.4.
Always replace both batteries with a new batterie 3,6V 1/2 AA, taking care of poles.
1.5) DURATION OF THE BATTERY
The battery life always depends on the frequency of use.
The following table indicates the indicative life of batteries according to their use:
N° Activations per day*
Battery life expected**
*Activations lasting about 10s
**Average temperature 25° C
10 4 years
2) PROGRAMMING
Before proceeding to the programming of the system,some aspects of the operating
principles must be highlighted.
Before programming, carefully read all instructions.
2.1) ACCESS PASSWORD
The programming of the device is protected by an access password which should
be immediately customized.
The factory-preset password is 123456.
Take note of the new password and keep it in a safe place for future uses.
If the password is lost, the device will have to be entirely reset, and all
memorised codes will be removed.
2.2) TRANSMISSION OF THE ADMINISTRATOR PIN
Once an Administrator PIN is stored, the device behaves essentially like a normal
radio transmitter, with the difference that it is possible to insert up to 255 different
PINs and each single PIN can have different types of encoding (Rolling code ARC,
Rolling code HCS, fixed code).

22
3) FUNCTION MENU
After activating the keypad, and typing the access password followed by #,
access is enabled to the Function Menu (2 beeps are heard from the buzzer).
IRI.KPAD awaits that one of the 9 Menu available is selected. During this dwell time,
a beep every 0.5sec is heard:
N. Function
1 Change of access password for programming menu
2 Entering an Administrator PIN
3 Entering a User PIN (advanced function)
4 Cancellation of a PIN
5 Entering down counter (advanced function)
6 Configuration Menu of operation
7 Configuration Menu of proximity switch
8 Verification menu of the type of encoding of a stored PIN
9 Enable Menu of # button for code repetition.
Press the desired menu button.
NOTE:
• The keypad is activated by pressing any key.
• Auto shut-off is 10 seconds.After this period of time the system must be switched
on again, as described above.
• To exit a programming menu without making any changes, press #, or wait for
20 seconds (time-out time).
• A possible programming error is indicated with a long beep, IRI.KPAD then exits
the programming phase.
MENUS DESCRIPTION:
MENU 1 (TO CUSTOMIZE THE ACCESS PASSWORD)
After typing key 1, the customization of the password phase is entered, indicated
by 2 beeps followed by an interval.
- Type in the new password (6 digit) and press #.
- IRI.KPAD confirms the typing with 3 beeps followed by an interval.
- Type in the new password once more and press #.
- If the two digits are the same the password is stored in memory and the keypad
returns to stand-by mode.
MENU 2 (TYPING IN OF ADMINISTRATOR PIN)
After typing key 2,the customization of the Administrator PIN code is entered,indicated by
2 beeps followed by an interval.The Administrator PIN can be composed of 1 to 9 digits.
- Type in the Administrator PIN and press #.
3 beeps, followed by an interval, are heard to confirm the operation.

23
The device is now waiting for a command which specifies the type of receiver coding
to be used for the Administrator PIN just typed in:
- Press 1 for the Rolling-code receivers
- Press 2 for the ARC receivers
- Press 3 for the Fixed-code receivers
TO MEMORISE ADMINISTRATOR PIN IN THE RECEIVER
After programming the PINs as desired, it is necessary to store them in the receiver.
When the receiver is waiting for a code to be stored, enter the PIN followed by #,
IRI. KPAD will send the code to be stored in the receiver.
More than one receiver can be used, also with a different decoding, and in the event
of multi-channel receivers, various codes can be matched to various channels.
In the event of especially complex installations, it is advisable to make and
carefully keep a diagram of the various receivers used, as well as their functions
and related IRI.KPAD PINS matched to it.
MENU 3
See paragraph on Advanced Functions
MENU 4 (PIN ERASING)
After typing key 4, the erasing phase of the code is entered, indicated by 2 beeps
followed by an interval.
- Type in the PIN to be erased and press #. Three beeps, followed by an interval,
confirm the operation.
MENU 5
See paragraph on Advanced Functions
MENU 6 (OPERATION CONFIGURATION)
Through the Menu the following is possible:
1) Activate or deactivate the buzzer.
2) Switch the back light on and off.
3) Enable or disable keypad activation by pressing the asterisk (*) key. This only
allows the asterisk key to activate the IRI.KPAD, again.
4) Enable or disable the first digit entered as re-activation of the device and first code
entered.This will not require pressing again for re-activation before entering the code.
5) Enable or disable the system lock for 3 minutes after 5 wrong codes are ente-
red, for greater security against attempts to force the code. Factory configuration
includes functions 1-2 active and 3-4-5 disabled. After typing key 6, the password
is required to have access to advanced functions. The password to have access to
the advanced functions is 654321 and it is not customizable. Press 6, two beeps
are heard, press 654321, press #, three beeps are heard followed by an interval,
one of the sequences are required by the device as follows in menu 6.