Becker R8/17RP+ Manual de usuario

R8/17...R40/17
Version: RP(+)
en Assembly and Operating Instructions
Tubular drives for roller shutters
Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.
Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

Table of contents
General ............................................................................................................................................................................... 3
Warranty ............................................................................................................................................................................. 3
Safety instructions ............................................................................................................................................................... 4
Instructions for the user................................................................................................................................................... 4
Instructions for installation and commissioning.................................................................................................................. 4
Intended use ....................................................................................................................................................................... 6
Installation........................................................................................................................................................................... 6
Assembling the drive ....................................................................................................................................................... 6
Undoing the mounting pin................................................................................................................................................ 7
Drive adapter safety catch ............................................................................................................................................... 7
Assembling the drive adapter with safety catch on the drive shaft................................................................................... 7
Disassembling the drive adapter with safety catch on the drive shaft .............................................................................. 7
Assembling and disassembling the drive adapter with separate drive adapter safety catch............................................... 8
Assembling and disassembling the drive adapter with screw connection ........................................................................ 8
Securing the drive against axial displacement.................................................................................................................... 8
Fixing the drive adapter to the barrel dia. 45 ...................................................................................................................... 8
Mounting the drive in the tube .......................................................................................................................................... 9
Setting the limit positions.................................................................................................................................................... 10
Deleting the limit positions using the programming unit......................................................................................................... 12
Upper anti-freeze mechanism ............................................................................................................................................. 13
Obstruction detection / Blockage detection ......................................................................................................................... 13
Information for the electrician ............................................................................................................................................. 14
Disposal ............................................................................................................................................................................ 14
Maintenance ..................................................................................................................................................................... 14
Technical data dia. 45 ........................................................................................................................................................ 14
What to do if...?.................................................................................................................................................................. 15
Sample wiring diagrams ..................................................................................................................................................... 16
Declaration of conformity ................................................................................................................................................... 18
2

General
These tubular drives are high-quality products with the following features:
•Ideal for use with roller shutters
•Automatic detection of limit positions thanks to intelligent electronic system with stop systems
∙Secure anti-lifting device (RP+)
∙Slight pressure applied to the roller shutter curtain makes it difficult to raise or reach under it (RP+)
∙Suitable for rigid aluminium, steel and wooden profiles
•Installation without stops possible (from upper point to lower point)
•Obstruction detection in down direction when using suspension springs (RP, RP+) and anti-lifting device (RP+)
•Blockage detection in up direction (e.g., end strip frozen to the window sill)
•The limit positions do not have to be reset: Changes in the shading solution are accommodated automatically when using stop
systems.
•Drive puts the roller shutter curtain under low tensile load
•Soft upper stop
•Several drives can be operated in parallel
•Compatible with existing drives with electronic limit switching (4-core connecting cable)
•Comprehensive range of the drive manufacturer's control units can be used
Please observe these Assembly and Operating Instructions when installing and setting the equipment.
The date of manufacture comes from the first four digits of the serial number.
The numbers 1 and 2 indicate the year and the numbers 3 and 4 indicate the calendar week.
Example: 24th calendar week in 2012
Ser. No.: 1224XXXXX
Explanation of pictograms
CAUTION CAUTION indicates a hazardous situation which, if not avoided, could
result in injury.
ATTENTION ATTENTION indicates measures that must be taken to avoid damage to
property.
Denotes user tips and other useful information.
Warranty
Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in
serious injuries, e.g., crushing of limbs. Therefore, structural modifications may only be carried out with our prior approval and
strictly in accordance with our instructions, particularly the information contained in these Assembly and Operating Instructions.
Any further processing of the products which does not comply with their intended use is not permitted.
The end product manufacturer and fitter have to ensure that all the relevant current statutory, official and, in particular, EMC regu-
lations are adhered to during utilisation of our products, especially with regard to end product manufacture, installation and cus-
tomer advice.
3

Safety instructions
The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury.
Instructions for the user
General information
•All work, including maintenance and cleaning, on electrical installations as well as other system parts
must always be performed by authorised specialists, in particular qualified electricians.
•Children from the age of 8 years and persons with reduced physical, sensory or mental capabilities or
lack of experience and/or knowledge may use these devices, provided they are supervised or have
been instructed in the safe use of the device, and have understood the hazards involved. Children must
not play with the device.
•Systems have to be checked regularly by authorised specialists for wear and damage.
•Always put damaged systems out of operation immediately until they are repaired by an authorised
specialist.
•Do not operate equipment if people or objects are within the danger zone.
•Observe the danger zone of the equipment during operation.
•Stop and disconnect the equipment from the mains power supply when maintenance and cleaning is
being performed either on the system itself or in the immediate vicinity of it.
•Ensure that there is adequate clearance (at least 40cm) between moving parts and adjacent objects.
Caution
Safety instructions for avoiding serious injuries.
•Crushing or shearing points must be avoided or protected.
Instructions for installation and commissioning
General information
•Observe the safety instructions in EN60335-2-97. Please note that this list of safety instructions is not
exhaustive, since it would be impossible for the standard to include all sources of danger. For example,
the design of the operated product, the way the drive works in the situation it is installed in or even the
way the end product is mounted in the end user's place of use cannot be taken into consideration by
the drive manufacturer.
If any questions or uncertainties regarding the safety instructions contained in the standard arise,
please contact the manufacturer of the part or end product in question.
•All applicable standards and regulations for electrical installation must be complied with.
•All work, including maintenance and cleaning, on electrical installations as well as other system parts
must always be performed by authorised specialists, in particular qualified electricians.
•Only use spare parts, tools and accessory devices which have been approved by the drive manufac-
turer.
Unapproved third-party products or modifications to the system and its accessories represent a risk to
your safety and the safety of others. This means that the use of unapproved third-party products, or
modifications which have not been agreed with or approved by us, are prohibited. We do not accept li-
ability for damage or injury arising from such actions.
•Position control devices within sight of the driven product, but away from moving parts, at a height of
over 1.5m.
•Permanently mounted control devices must be positioned where they can be seen.
•Rated torque and duty cycle must be suitable for the requirements of the driven product.
Technical data – rated torque and service life can be found on the type plate of the tubular drive.
4

•Moving parts of drives must be installed at a height of over 2.5m above floor level or any other surface
from which access to the drive is gained.
•To ensure safe operation of the system after commissioning, the limit positions must be correctly set/
programmed in.
•Drives with a H05VV-F connecting cable may only be used indoors.
•Drives with a H05RR-F, S05RN-F or 05RN-F connecting cable may be used both indoors and outdoors.
•To connect the drive to the driven part, solely mechanical accessory components made by the drive
manufacturer from the current product catalogue may be used. The components must be installed in
accordance with the manufacturer's instructions.
•If the drive is used for shading solutions in a specially marked area (e.g., escape routes, hazard zones,
safety areas), compliance with all applicable regulations and standards must be ensured.
Caution
Safety instructions for avoiding serious injuries.
•When electrical or electronic equipment and units are operated, certain components,
e.g., the power supply unit, are live. Physical injuries or damage to property can result in
the event of unauthorised interventions or failure to heed warnings.
•Be careful when touching the tubular drive, as it heats up during operation for technolo-
gical reasons.
•Before installation, shut down all lines and control devices that are not essential for op-
eration.
•Crushing or shearing points must be avoided or protected.
•When installing the drive, all-pole disconnection from the mains with a contact gap of at
least 3mm per pole must be provided (EN60335).
•If the mains connecting cable is damaged, it may only be replaced by the manufacturer.
Attention
Safety instructions for avoiding property damage.
•Ensure that there is adequate clearance between moving parts and adjacent objects.
•The drive must not be carried by the mains connecting cable.
•All latching connections and fastening screws on the brackets must be checked to en-
sure that they are secure.
•Ensure that nothing rubs against the tubular drive, such as shading solution attach-
ments, screws, etc.
5

Intended use
The type of tubular drive described in these instructions is intended solely for the operation of roller shutters.
This type of tubular drive supports not only curtain attachment by means of springs but also mechanical anti-lifting devices (e.g.,
Zurfluh-Feller, Simu, GAH Alberts and Deprat). These are detected automatically.
If the springs or the top lath are rigidly connected to the barrel (screwed, rivetted, etc.), please use only the tubular drive type RP,
as the RP+ drive could detect this as an anti-lifting device and could damage parts of the system.
For sun protection applications, please use only the types of tubular drive designed for this purpose.
This type of tubular drive is designed for use in single systems (one drive per barrel).
The tubular drive must not be used in potentially explosive areas.
The connecting cable is not suitable for transporting the drive. Always carry the drive by the housing tube.
Other applications, uses and modifications are not permitted in order to protect the safety of the users and others, since these ac-
tions can impair the system’s safety and carry the risk of personal injury and property damage. The drive manufacturer does not
accept liability for damages or injury arising from such actions.
Always observe the information in these instructions when operating or repairing the system. The drive manufacturer does not ac-
cept liability for damage or injury resulting from improper usage.
Attention
Only use anti-lifting devices if the roller shutter laths are sufficiently strong. The closed
curtain must not project beyond the guide tracks or else there is a risk of the joint between
the top two laths being subjected to excessive strain and getting damaged.
Installation
Assembling the drive
Attention
To connect the drive to the driven part, solely mechanical accessory components made by
the drive manufacturer from the current product catalogue may be used.
Prior to mounting, the fitter must ensure that the masonry and the system being motorised are sufficiently robust (drive torque plus
weight of the shading solution).
Caution
Electrical connections may only be carried out by a qualified electrician. Prior to assembly,
the power supply must be disconnected and secured. Please give the enclosed connection
information to the responsible electrical contractor.
Calculate the space required at the side (M) by measuring the drive head and wall
bracket. The clear dimension of the box (X) minus the space required at the side (M)
and idler (G) gives the length (L) of the barrel: L=X-M-G.
The space required at the side (M) varies depending on the combination of drive and
wall bracket.
Then mount the wall bracket and idler. Ensure that the barrel is aligned at right angles to the wall and that sufficient axial play is al-
lowed for the mounted system.
Attention
When using rigid shaft connectors, closed brackets must be fitted. The tubular drive
presses the closed curtain down to make it difficult for people to reach under it or raise it.
Only use curtains made of sufficiently strong material, such as aluminium, steel or wood.
To prevent damage to the curtain it must run in guide tracks from top to bottom.
6

Undoing the mounting pin
When pushed in, the mounting pin locks automatically. To undo the mounting pin,
either insert the screwdriver, max. dia. 2.5 mm, (2) into the hole and push upwards,
or push a flat-head screwdriver with a width of approx. 8mm (1) into the groove.
Drive adapter safety catch
Assembling the drive adapter with safety catch on the drive shaft
Disassembling the drive adapter with safety catch on the drive shaft
Disassembly with disassembly tool, Item no. 4930 300 606 0
Disassembly with long nose pliers
2.
1.
7

Assembling and disassembling the drive adapter with separate drive adapter safety catch
Assembling and disassembling the drive adapter with screw connection
Securing the drive against axial displacement
-10 mm
In order to secure the drive against axial displacement, we recommend screwing the
drive adapter to the tube.
Attention
When drilling into the barrel, never drill near the tubular drive!
Fixing the drive adapter to the barrel dia. 45
Size of drive
[mm]
Diameter of barrel
[mm]
Torque
max. [Nm]
Fastening screws
for drive adapter (4 pc.)
dia. 45 50-70mm plastic drive adapter 25 Self-tapping screw
dia. 4.8 x 9.5mm
dia. 45 50-85mm plastic drive adapter
for obstacle detection
40 Self-tapping screw
dia. 4.8 x 9.5mm
dia. 45 50 - 85 mm diecast drive adapter 50 Self-tapping screw
dia. 4.8 x 9.5mm
We also recommend screwing the idler to the barrel.
Attention
Do not hammer the tubular drive into the tube or drop it into the barrel! The curtain can only
be secured using springs or rigid shaft connectors.
8

Mounting the drive in the tube
For profile tubes:
In the case of some drive adapters, tolerances of the groove widths in different bar-
rels can be offset by rotating the drive adapter into a different groove recess. These
groove recesses have different sizes and allow the drive to fit exactly.
For round tubes:
First notch the tube on the motor side, so the lug of the thrust ring can also be pushed
into the tube. There must be no play between the lug of the thrust ring and the tube.
For rings without drive lugs, which are used to assist fitting on the thrust ring, the bar-
rel must be connected to the thrust ring by a 4.8 x 9.5 mm self-tapping screw.
Assemble the tubular drive with the relevant thrust ring (1) and drive adapter (2). In-
sert the tubular drive with the pre-assembled thrust ring and drive adapter into the
tube to achieve a form fit. Ensure that the thrust ring and drive adapter are secure in
the tube.
Mount the assembled unit comprising barrel, tubular drive and idler on the box and secure the drive according to the type of wall
bracket fixing with a split or spring pin.
Automatic setting of limit positions is possible, where a stop system is present on
both sides, using the switch (Item no. 4901 001 158 0), a standard rotary switch or
the programming unit for drives with electronic limit switching (Item no. 4935 200 011
0). All other functions can only be set via the programming unit.
Connect the wires of the tubular drive to those of the same colour in the program-
ming/operator control and switch on the power supply.
The switch and the programming unit are only meant for the commissioning, not for con-
tinuous operation!
Position the barrel so that the roller shutter curtain can be attached with springs or fit the rigid shaft connectors in accordance with
the manufacturer's instructions.
Attention
The switch and the programming unit are only meant for the commissioning, not for con-
tinuous operation!
When using springs/anti-lifting devices, we recommend you use at least three; for longer
tubes, use three springs/anti-lifting devices per meter of barrel.
Lay the connecting cable
Lay the connecting cable up to the tubular drive, and fix The connecting cable and
any antennae must not project into the winding chamber. Cover any sharp edges.
9

Setting the limit positions
Programming button Travel button
Programming unit for drives with electronic limit switching.
Attention
The programming unit is only designed for the commissioning, not for continuous opera-
tion.
Intelligent installation management
Limit position status indicator
A brief stopping and restarting indicates that no limit position has been set in that direction of movement.
Completion of installation following automatic setting of limit position "Stop"
The drive saves the limit position "Stop" permanently once the it has been reached 3 times in succession. Installation is then com-
plete.
There are 4 ways to set the limit positions:
•Upper stop to lower stop
•Upper point to lower point
•Upper stop to lower point
•Upper point to lower stop
The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times.
If the tubular drive switches off prematurely while opening or closing, due to an obstruc-
tion, the obstruction can be cleared by reversing a short way and removing the obstruc-
tion. The desired limit position can be set by opening/closing again.
When first installing, using springs and adjusting the limit position ‘...to lower stop’, the
barrel in the lower limit position turns approx. 1/4 of a turn further than usual. In doing so,
the tubular drive is able to automatically detect the use of anti-lifting devices or springs.
The tubular drive switches off automatically. Type and source of the risk
Upper stop to lower stop
Open to the permanent upper stop.
▻The tubular drive switches off automatically.
Then close to the permanent lower stop.
▻The tubular drive switches off automatically.
►The limit positions are now set.
10
Este manual sirve para los siguientes modelos
4
Tabla de contenidos
Otros manuales de Mando a distancia de Becker

Becker
Becker Centronic SunWindControl SWC745-II Manual de lista de piezas

Becker
Becker P5-16-C01 Manual de usuario

Becker
Becker Centronic SunWindControl SWC441A-II Manual de usuario

Becker
Becker Centronic SWC441 Manual de usuario

Becker
Becker EVO 20 RJ Manual de usuario

Becker
Becker EasyControl EC541A-II Manual de usuario

Becker
Becker M05 Manual de usuario

Becker
Becker P3-30 Manual de usuario

Becker
Becker EasyControl EC541A-II Manual de usuario

Becker
Becker CentronicPLUS SWC548A PLUS Manual de usuario


















