7 | Page
Manual operation (No DMX connected)
The way the manual operation works is dependent on the resolution setting.
If set to
All 8 / All 16
When the Pipeline 4 Way Controller is switched on the display will show the light level
e.g. “ 0”
Use the UP and DOWN buttons to set the desired light level.
The level will be autosaved after 10 seconds, indicated by display readout “SAVED” or
can be saved instantly by pressing ENTER after setting the light level.
After saving a light level the ENTER button can be used to toggle between 0 and the saved level.
The display reads out “MANUAL” for 0.
(If “MANUAL” doesn’t give you level “0”, check that “noDMX” is not set to “man”)
If power is lost, the unit will, when power is restored, automatically go to the saved light level after 5 seconds.
If a DMX signal is connected when in Manual mode, the unit will switch to DMX mode.
Removing the DMX signal will not cause the unit to switch back to Manual mode.
To reenter Manual mode; navigate to MANUAL in the menu OR remove DMX signal and switch unit off and then back on.
Individual 8 / Individual 16
When the Pipeline 4 Way Controller is switched on the display will show the light level for the first pipe
e.g. “n1 0”
Use the UP and DOWN buttons to set the desired light level for Pipe 1
- press Enter to store the selected level and to go to the next pipe.
The display will read out e.g. “n2 0”
Use the UP and DOWN buttons to set the desired light level for Pipe 2
- press Enter to store the selected level and to go to the next pipe.
etc.
The level of the selected pipe will be autosaved after 10 seconds when doing nothing, indicated by display readout
“SAVED”
The display reads out “MANUAL” for 0 (If “MANUAL” doesn’t give you level “0”, check that “noDMX” is not set to “man”)
After saving the light level, it is possible to toggle between the saved light levels and 0, by, in turn, clicking the MENU &
ENTER
The display reads out “MANUAL” for 0
(If “MANUAL” doesn’t give you level “0”, check that “noDMX” is not set to “man”)
If power is lost, the unit will, when power is restored, automatically go to the saved light level after 5 seconds.
If a DMX signal is connected when in Manual mode, the unit will switch to DMX mode.
Removing the DMX signal will not cause the unit to switch back to Manual mode.
To reenter Manual mode; navigate to MANUAL in the menu OR remove the DMX signal and switch unit off and then back
on.
CCT 8 / CCT 16 (Can be selected for any pipe combination, but only works with 3200/5600K pipes combination)
When the Pipeline 4 Way Controller is switched on the display will show the light level e.g. “ 0”
Use the UP and DOWN buttons to set the desired light level for the Pipeline 4 Way Controller.
- press Enter to store the selected level and to go to the color temperature.
The display will read out e.g. “3200 K” Set the desired color temperature and press enter to save it.
The level and color temperature will be autosaved after 10 seconds, indicated by display readout “SAVED” or
can be saved instantly by pressing ENTER after setting the light level.
After saving the light level, it is possible to toggle between the saved light levels and 0, by, in turn, clicking the MENU &
ENTER.
The display reads out “MANUAL” for 0.
(If “MANUAL” doesn’t give you output level “0”, check that “noDMX” is not set to “man”)
If power is lost, the unit will, when power is restored, automatically go to the saved light level after 5 seconds.
If a DMX signal is connected when in Manual mode, the unit will switch to DMX mode.
Removing the DMX signal will not cause the unit to switch back to Manual mode.
To reenter Manual mode; navigate to MANUAL in the menu OR remove DMX signal and switch unit off and then back on.