b-intense b-control deluxe Manual de usuario

© b-intense®
Version 01/2021
Made in Austria
INFRAROTKABINEN
DE
FR
EN
NL
inkl. Anschlussplan der b-control Steuerungen
incl. installation manual of the b-control units
avec instructions de montage des systèmes de commande b-control
incl. montagehandleiding b-control besturingsinrichtingen
Bedienungsanleitung
b-intense®Infrarotkabinen
Operating Instructions
b-intense®infrared cabins
Manuel d’utilisation des cabines
à infrarouges b-intense®
Gebruiksaanwijzing b-intense®
infraroodcabines
230 Volt

36
EN

37
EN
Page Topic
CONTENT
39 General safety guidelines
40 General safety information
41 General warning notices
43 General application notes
44 Scope of application of b-intense®infrared cabins
47 Operation of the b-control units
49 Effects of wellness supplements
50 b-intense®moments App and Bluetooth function
51 Infrared programs
59 Cleaning and care of the b-intense®infrared cabin
60 Maintenance instructions
60 Disposal of the b-intense®infrared cabin
61 Certificate of Warranty
61 Declaration of conformity
63 Annex

38
EN
IMPORTANT SAFTEY GUIDELINES. PLEASE READ CAREFULLY AND
KEEP SAFE FOR LATER USE.
Welcome to the world of health and wellbeing of b-intense®infrared cabins!
We are pleased to welcome you as a b-intense®customer. Congratulations on the purchase of your b-intense®infrared cabin, we extend
our thanks for the trust you have placed in our product. With b-intense®you bought a high quality product. Some of the obvious USPs of the
b-intense®products are the intensive effect and the high manufacturing quality. We place great value on modern design, reduced structures
in the arrangement and integration of intuitive technology elements, and the selection of modern colours and materials.
The heart of our b-intense®infrared cabin is the infrared technology. The b-intense®infrared heater, especially developed and designed by
b-intense®, is not comparable with conventional infrared technologies. With this patented technology we offer our customers the effective
and full-spectrum health promoting effect in long-studied and independently tested composition. Due to the particular innovation of the
spliced, high quality protective glass the b-intense®heater is 100% hygienic.
The name b-intense®stands for an intense experience of wellness and health and encourages you to enjoy life with all its
advantages and with all your senses.
We wish you great pleasure and enjoyment every time you use your exclusive b-intense®infrared cabin and, to ensure you get the best use
from your purchase, we would like to make you familiar with a few operating instructions.
Please read these instructions carefully before installation and first use of your new b-intense®infrared cabin and keep them safe.
Your b-intense®team

39
EN
General safety guidelines
The b-intense®infrared heaters have been tested by TÜV Austria and positively evaluated by the Austrian Institute
of Technology Seibersdorf.
All electrical components comply with CE safety regulations. Check the b-intense®heaters for any foreign bodies before use to prevent
accidents. The b-intense®heaters comply with the relevant safety regulations for electric heating appliances. In case of damage of any kind
to the heaters, do not start your infrared cabin and consult a professional engineer to repair the damage or to replace parts of the system.
Observe safety instructions before use.
Store and operate in a dry environment.
Humidity must not excel 60%.
Not condensing.
Safety Warning: Never cover an infrared heater!
Make sure that the heater is not covered and no items are put on it.
Covering the infrared heater may cause a fire hazard.
Follow all safety instructions in this manual! Work on the
electrical wiring must only be carried out by a qualified electrician.
Turn the b-intense®cabin off first and always unplug it before repair
and maintenance or cleaning work is carried out!
There is a danger of electric shock!
Made in Austria
!

40
EN
General safety information
Check the required power supply. The operating voltage is announced
on the nameplate on the control and the infrared heaters.
1. The IR cabin must only be operated on an earthed shockproof socket,
which was installed and checked by a lincensed electrical company.
2. The used socket must only be operated with a fault-current circuit
breaker (FI) with a trip current of max 30mA and a circuit breaker
(safety device) of max 16A.
3. The used socket should be easily accessible after installation.
4. The IR cabin must not be operated on a multiple socket (fire hazard).
5. If used commercially, a professional annual check of the electrical
installation must be ensured by the operator.
Only original b-intense®component parts are safe for use. The use
of not certified components can lead to damages or injuries. Waranties
and guarantees expire with the use of not certified components.
Plugging the cabin in and out is only permitted by pulling the plug,
which is connected to the cable. Don‘t pull the cable itself, this could
damage the cable and lead to an electric shock.
Using this device next to other devices should be avoided, for it could
lead to incorrect operation. If it is necessary, all affected devices should
be monitored, to secure regular operation.

41
EN
If you feel burning or pain in the radiated
area, reduce the intensity of the back
heater immediately.
We recommend a warm shower and
applying a nurturing, moisturizing
lotion onto the still warm skin after
the infrared application.
General warning notices
Ensure that liquids do not come into
contact with the heaters or with the
timber facings.
Make sure that the heater is not
covered and that there are no objects
placed on it.
Avoid any contact with the heater while it
is in operation and immediately afterwards.
The high surface temperature of the heater
can cause burns.
Make sure that your hair does not
touch the heater while it is in operation.
Tie your hair up to leave your back
uncovered.
Allow the infrared heater to cool down for
10 minutes before re-starting the cabin.
Do not use the cabin within 24 hours
after sunbathing or using an artificial
UV source (e.g. sun bed).
Children are not allowed to play with
the device or to carry out any cleaning
or maintenance work.
Persons with limited sensation of heat,
persons under the effects of alcohol,
drugs, tranquilizers, are not allowed to
use the cabin.
Consult your doctor independently
concerning your infrared treatment after
operations, in case of illness, injuries,
pregnancy or in the case of plastic or
medical implants, as well as where there
is a risk of overheating, such as persons
with cardiovascular diseases or when
taking medication.
If you experience any discomfort, stop
your infrared treatment immediately!
If overheating occurs or if you feel the
temperature is too high, you can reduce
the radiation intensity or open the door
and switch on the ventilation.
Do not stare at an infrared heater for more
than 10 minutes. We recommend safety
glasses for sensible eyes (at least protection
level 4-4 by EN 171).
Exchange electronic components solely with
original components of the manufacturer.
All repairs must be performed by a qualified
engineer authorized by b-intense®.The
electrical components must not be opened.

42
EN
Special note: Use by children
Children until the age of 7 may not use the infrared cabin. Children over the age of 7 years as well as adolescents, who can follow instruc-
tions of operating personnel, are allowed to use the cabin under supervision. The heat settings must be adapted to the needs of children
and adolescents by the supervising adult. Adjust the headrest, so the radiation doesn‘t impact the back of the head directly.
Special note: Red back
A distinct redness in the exposed back area ist normal and desired, and happens due to the increased blood circulation. If the redness is
still visible more than 3 hours after application, reduce the radiation intensity or the duration of use the next time.
For questions or ambiguities please write a message to office@b-intense.at.

43
EN
General application notes
b-intense®infrared cabins can be used
by the whole family.
You can enjoy your b-intense®infrared
cabin daily.
We recommend infrared sessions of
approx. 30-50 minutes, depending on
personal well-being, or a b-intense®
infrared program. After 60 minutes the
cabin switches off automatically.
A b-intense®infrared cabin doesn‘t
need preheating. Just sit down, switch it
on and enjoy immediately.
The infrared radiation must strike the skin
directly. Sit in the cabin with the upper body
naked, so that your spine is positioned direct-
ly in front of the back radiator, and lean back.
Usually, sweating starts after 10-15 minutes.
Adjust the neck support, so that the radiation
does not hit the back of your head directly.
Regulate the b-intense®infrared heater
intensity and adjust the additional features
according to your needs via the control
unit.
The b-intense®infrared control units
offer pre-installed user programs, e.g.
back, heatload or slim. See detailed
description on page 51.
Use a towel while sitting in the cabin.
The temperature in the b-intense®
infrared cabin reaches between 25°
and 40°C.
Mind your fluid balance and drink a glass
of water before and after each use of the
infrared cabin.
A lukewarm shower is recommended
after every infrared application. We also
suggest applying a nurturing, moisturi-
zing lotion.
100%
50%
75% 25%
100%
50%
75% 25%

44
EN
Scope of application of b-intense®infrared cabins
b-intense®infrared cabins consist of infrared radiators, control units and additional equipment for local, non-contact heat application via
back and front heater to reduce muscle tension and to help in the treatment of pain and tension therapies, to increase the body‘s defenses
and gain a positive effect on the skin.
Intended application
› The b-intense®infrared cabin is intended for infrared therapy according to the specified purpose.
› The product is intended for private use.
› Commercial use must be agreed upon with b-intense®.
› Intended application also includes fully reading and understanding the associated documentation and in particular these „safety
instructions“.
Not intended application
› Every use that doesn‘t comply with the intended application is not intended and therefore prohibited.
› The product must only be used with b-intense®licensed components. b-intense®is not liable for any damage occuring through
unintended use. The risks of unintended use lie within the operator/user.
General safety guidelines and use of the b-intense®
› Read the Operation Manual thoroughly including the medical acvide.
› Always check the b-intense®cabin for visual damage.
› Ensure the conformity of the electric connection with the specification on the nameplate.
› Ensure the proper connection and inspection of the shockproof socket.
› Ensure the proper protection and connection to a fault-current circuit breaker (FI) of the socket.
› Please do not locate the b-intense®in wet rooms, only in dry rooms (no condensing humidity).
› Never cover the infrared heaters!
› Keep easily flammable substances and fluids away from the infrared heaters.
› Don‘t leave the b-intense®operating unsupervised.
› In case of visual damage of the cabin contact b-intense®.
› Never open the electrical components of the b-intense®.
› In case of damage on the supply cable disconnect the b-intense®from the power supply and contact b-intense®.
› Don‘t modify or adapt the b-intense®!
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario











