AZUD FBC 103 N Manual de usuario

92000002-12
Sistema Azud, S.A. Tel. + 34 968 80 84 02 Fax: + 34 968 80 83 02 E-mail: [email protected] www.azud.com
CONTROL UNIT 220-110 V AC
AZUD FBC 103 N
AZUD FBC 112 N
USER’S MANUAL
Water Filtration Solutions

Water Filtration Solutions
1
This manual is subject to modifications without prior warning.
System of symbols used in this manual:
In the reading of this manual you will find some signs used as information points to warn and to identify
risks. This is the format and content of these messages:
The failure to obey the instructions and warnings could cause damage to
people, the equipment and the surrounding area.
The failure to obey the instructions and warnings could cause direct
damages to people derived from an electric risk

Water Filtration Solutions
2
1. INTRODUCTION 3
2. CHARACTERISTICS OF THE CONTROL UNIT
2.1 Introduction 3
2.2 Identification of the product
2.3 Technical Data of the Control Unit
2.4 Types of activation and backflushing cycles
2.5 Working Description
3. PROGRAMMING OF AZUD FBC CONTROL UNIT___________________________________ 6
3.1 AZUD FBC Site Map
3.2 Anticipation time of Sustaining Valve
3.3 Backflushing time of each station
3.4 Time between stations
3.5 Time between backflushings
3.6 Delay of the Differential Pressure Gauge
3.7. Number of Stations of the Filtration Equipment
3.8. Adjustment of the different differential pressure gauges
4. AUXILIARY ELEMENTS 9
4.1 How to activate backflushings by external signal
4.2 How to connect an element which cancels temporally backflushes
4.3 Anticipation signal. Sustaining Valve
4.4 How to activate backflushes by real filtration time
5. COMPONENTS AND SPARE PARTS 11
6. SAFETY INFORMATION 12
7. INSTALLATION INSTRUCTIONS________________________________________________ 13
7.1 Installation of the Control Unit's support
7.2 Hydraulic connection of the Control Unit with the Filtration Equipment
8. ELECTRIC CIRCUITS 16
9. MAINTENANCE INSTRUCTIONS 21
10. POSSIBLE PROBLEMS – CAUSES - SOLUTIONS 22
11. WARRANTY 25
INDEX

Water Filtration Solutions
3
AZUD FBC Control Unit is able to control the automatic backflushing of the filtration equipmentswith
different possibilities of start and actuation. AZUD FBC Control Unit integrates the detection, control and
activation systems of the backflushing cycle of the filtration systems.
Electronic control system. Integrated controller to control all the detection and activation functions. It is
assembled on an electric cabinet with degree of protection IP 55.
Detection system. Easy reading differential pressure gauge.
Activation system. 24 V NC three-way electrovalves
All these is completely assembled and contains the auxiliary elements which complete the electric and
hydraulic system and which turns the Control Unit into an independent and automatic system.
2.1 Introduction.
1. Introduction
2. Characteristics of the Control Unit.
2.2. Identification of the product.
In AZUD we identify each Control Unit with an industrial label withauniqueserialnumber.The
factory identifies the different control units with these labels.
The modification or elimination of the
label cancels any warranty; and so
impedes the identification of the
Equipment.
The industrial label indicates: the model of
the equipment, the number of stations and
the serial number.
NUMBER OF STATIONS
SERIAL NUMBER
MODEL
Thank you very much for your confidence in AZUD FBC control units to solve your Filtration
Equipments Automation needs. Please, read carefully this manual and you will find the answer to most
of your questions.
However, IF YOU HAVE ANY DOUBT OR NEED ADDITIONAL INFORMATION, PLEASE CONTACT
All the control units manufactured in SISTEMA AZUD, S.A are subject to strict quality control tests and
are manufactured under a productive process which meets the requirements of the standard ISO
9001/2000.
Sistema AZUD is also committed with the environment, and is certified under the Environmental
Management System of the standard ISO 14001.
This Manual contains some instructions and warnings which should be observed
to obtain a correct installation, operation and subsequent maintenance of the
Control Unit.

Water Filtration Solutions
4
1- By interval of working time of the installation.
2- By differential of pressure.
3- By external or remote signal.
4- Manually.
A backflushing cycle will be activated each time the programming time passes.
A backflushing cycle will be activated each time there is a differential of
pressure in the equipment equal or higher than the regulated in the
Differential Pressure Gauge, and after the confirmation time of the pressure
gauge programmed in the FBC.
A backflush will be activated when sending a contact free of tension to the corresponding input
of the FBC trough an external or remote signal.
OK
2.4 Types of activation and backflushing cycles.
You can activate a backflushing cycle manually, through the
keyboard of your Control Unit. The backflush will be activated when
you keep pressed for some seconds the key OK.
AZUD FBC Control Unit will allow to keep all this options at the same time, or select just some of
them.
2.3 Technical Data AZUD FBC Control Unit.
Do not connect AZUD FBC Control Unit in installations fed by a power
generator. The variations in voltage could damage it.
VOLTAGE 220 V AC
CONSUMPTION 0.5 A
OUTPUT FUSE 2 A 24 V
5 x 20 mm
FEEDING FUSE 0.5 A 220 V
5 x 20 mm
SOLENOIDS BAJO CONSUMO
OUTPUT CONSUMPTION MÁXIMO 1 A
ADMISSIBLE TEMP. 5 – 50ºC
OUTPUTS INPUTS
103 112 103 112
NUMBER 4 13 4 4
TYPE VOLTAGE
CONTACT
FREE OF
VOLTAGE
IT IS POSSIBLE TO CHANGE THE LANGUAGE OF THE CONTROL UNIT
SPANISH ENGLISH

Water Filtration Solutions
5
Working Description:
• The start of the sequential self-cleaning process is made when the Control Unit activates the
backflushing cycle under one of the four possible orders: existing differential of pressure, attending to
the frequency of irrigation, by direct actuation on the keyboard or by external signal.
The programmer which integrates the Control Unit, activates the electric contact which supplies
voltage to the NC solenoid, in charge of activating the first station that makes the self-cleaning
process; transforming the electric signal in a hydraulic signal in charge of feeding the chamber of the
3-ways valve.
Through the feeding of the chamber of the 3-ways valve it is made a movement of the internal piston
which closes the entrance of water to the filter and communicates the interior of the filter with the
drainage manifold. This allows the filtered water from the rest of filter from the outlet manifold,
introduces to the filter in the opposite way from the filtration direction, activating the self-cleaning
mechanism of DF-DISC filtration discs.
The deactivation of the solenoid from station n.1 allows the 3-ways valve come back to the resting
position and the filter to the filtration process.
Once the station n.1 has finished the backflushing process, this is repeated sequentially until finishing
all the stations in the filtration equipment.
The end of the self-cleaning process coincides with the closure of the drainage outlet and the opening
of the inlet to the filter from the inlet manifold, being re-established the initial filtration conditions.
2.5.- Working Description.
AZUD FBC Control Unit integrates all the control, detection and operation elements that allow AZUD
HELIX AUTOMATIC filtration equipment to have complete autonomy. All the components are supplied
already assembled, with the auxiliary elements that complete the electric and hydraulic system, which
turn the Control Unit into an autonomous and automatic system.
The electronic control system and the electric auxiliary elements are placed in a water-tightness housing,
completely isolated from the hydraulic components.

Water Filtration Solutions
6
The key allows the access from any screen to the main screen.
Press the key before making consult or modification in the programming values.
The numeric values in red are can be changed by the user.
Keep pressed to activated manually a whole backflushing cycle.
Press to stop the backflushing process.
SCREEN: AZUD FBC has a four
lines screen
Left arrow:
Utilities
Right ArrowUp arrow: Screens
backward
Down arrow:
screen advance
AZUD
11:08
OK: Confirmation
Data advance and
backward
ESC= Exit
3.1. Control Unit Site Map
3. Programming of AZUD FBC Control Unit.
AZUD
00:00
ADVANCE
MASTER
VALVE
0:00
BACKFLUSHING
TIME
STATIONS
15 seg
TIME
BETWEEN
STATIONS
15 seg
BACFLUSHING
BY TIME
15 seg
DELAY
START
PD
15 seg
NUMBER
OF
STATIONS
8
Acces to UTILITIES SCREEN:
Keep pressed
If the screen has more than a numeric value to
modify we can select it with the direction keys
To modify the numeric value in the screen
- Press the key
- Increase / decrease the numeric value
- Validation of the new value
TOTAL
SUMMATOR
OK = DELETE
PARTIAL
SUMMATOR
0
OK = DELETE
TOTAL
BACKFLUSHIG
CLOCK
ADJUSTEMENT
16:10
Set hour
dd/mm/yyy
14/05/2010
16:10 Jue

Water Filtration Solutions
7
Following the different parameters to be programmed of your Control Unit will be introduced. AZUD FBC
incorporates a standard programming which allow the user to start up the filtration equipment by the first
time and being familiar with the programming to be adapted to the particular conditions of your
installation.
Anticipation time of the signal of the sustaining electrovalve, which allows this to reach its regulation of
pressure before starting the backflushing cycle.
If your equipment does not have this option press time 0 sec.
3.2 Anticipation time of the sustaining valve.
Time that remains active each one of the filtration stations which made the filtration system. The
programmed time is the same for all the stations. During one cycle of activations it is made sequentially
one activation for each station the system has programmed.
3.3 Backflushing time of each one of the stations.
Time that passes from the stop of the actuation of one filtration station and the start on the activation of the
following.
During this time the system deactivates all the outlets active (general outlet).
3.4 Time between stations.
3.5 Time between backflushing stages.
Minimal frequency to make the activation of a backflushing cycle, always the system in active filtration
process.
3.7 Delay of the differential pressure gauge.
It is defined as the necessary time in which the contact must be closed in a continuous way in the
corresponding inlet of the differential pressure gauge for one activation order to be effective and the
backflushing cycle is activated. This is a performance especially indicated to avoid unnecessary
backflushings provoked by the start of the filling of the installation. (Start-up of the installation).
Select the number of stations of your filtration equipment.
3.8 Number of Stations of the Filtration Equipment
3.6 Deposit filled time
Select the filling time of the auxiliary tank (always in SECONDS). The minimum and maximum time
interval that can be programmed is 20-150 sec respectively

Water Filtration Solutions
8
The differential pressure you should regulate in your differential pressure gauge should be between 0,2
– 0,3 bar over the pressure with the maximum flow of your system, when the filters are clean.
1- AZUD Differential pressure gauge adjustment.
Regulate the differential pressure gauge according to the model.
3.8 Adjustment of the different types of differential pressure gauges.
Azud FBC Control Units include a differential pressure gauge which indicates the differential pressure
existing in the installation and provides us with a free-tension contact once the pre-established
differential pressure is exceeded. The differential pressure reading is carried out through two P1 and P2
inlets (see hydraulic linkages), which are collected in the inlet and outlet manifold respectively.
The differential pressure value in an equipment's inlet and outlet is not the same in all the installations.
So you must regulate the differential pressure value which will activate a backflushing cycle in the
equipment. The Control Unit has been calibrated at 0.6 Bar by the factory. You must regulate this value
according to the installation conditions.
The differential pressure gauge is provided with a regulator device to movethe
small hand, modifying the maximum value of the pressure difference.
EXAMPLE
ARECENTLY INSTALLED SYSTEM which working with a MAXIMUM FLOW, has a 0,1 bar
DIFFERENCE of pressure .
The recommended value is 0,3 - 0,4 bar.

Water Filtration Solutions
9
If you want to backflush by remote control,
using any other mechanism…
Connect to the input nº 3 and to the common
the external sign.
123
INPUTS
INPUTS
4
COMMON
INLETS
4. Auxiliary Elements
4.1. How to activate backflushes by external signal
Connect one of the outlets to input 4
and the other to the common.
To cancel the backflushes
connect input 4 with the
common (by means of a jumper)
123
INPUTS
INPUTS
4
COMMON
INLETS 123
INPUTS
INPUTS
4
COMMON
INLETS
If you wish to temporarily cancel backflushes while any
equipment or installation element are operating:
4.2. How to connect an element which temporally cancels the backflushes
This signal can be used for the connection of any element which needs to be activated in advance
and during the backflushing cycle.
4.3. Anticipation signal. Sustaining valve.
OUTOUTOUT 1 2 3 4
COMMON
OUTPUTS
FBC 103
OUTOUTOUTOUT1 2 3 4 5678
COMMON
OUTPUTS
9
E 0 2
E 0 4
E 0 1
E 0 3
FBC 112
This option can be used to the installation of a Pressure Sustaining Valve.
AZUD HELIX AUTOMATIC Equipment needs to guarantee a minimal pressure during the backflushing
of the stations. If your installation does not fulfil this requirement, AZUD can supply an adequate
Sustaining Valve to your installation.
-MOBILE PHONE
-PC
-SIMPLE PUSH-BUTTON
- ....
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario